1、AMSC N/A FSC 5930 INCH-POUND MS25214G 13 April 2010 SUPERSEDING MS25214F 1 February 2006 DETAIL SPECIFICATION SHEET GUARD, SWITCH, 3 POSITION This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the switch described herei
2、n shall consist of this specification sheet and MIL-DTL-7703. FIGURE 1 Dimensions and configuration Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25214G 2 Inches mm Inches mm Inches mm .003 .08 .240 6.10 .828 21.03 .005 .13 .248 6.30 .840 21.34 .
3、008 .20 .276 7.01 .875 22.22 .031 .79 .312 7.92 .906 23.01 .032 .81 .360 9.14 .937 23.80 .050 1.27 .469 11.91 1.062 26.97 .062 1.57 .516 13.11 1.093 27.76 .081 2.06 .594 15.09 1.312 33.32 .096 2.44 .688 17.47 1.344 34.14 .125 3.18 .719 18.26 1.562 39.67 .156 3.96 .750 19.05 1.635 41.53 .188 4.77 .82
4、5 20.95 1.812 46.02 2.125 53.98 FIGURE 1.Dimensions and configuration Continued Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25214G 3 DASH NO. OPEN FORCE TYPE PANEL THICKNESS (REF) REMARKS -1 1/ 1.0 to 2.5 LBS 3- HOLE MOUNTING .050 TO .081 -2 1-
5、 HOLE MOUNTING .050 To .248 -3 IDENTICAL TO -2, EXCEPT KEYWAY IS ROTATED 180 1/ Inactive for new design, use for replacement only. FIGURE 1.Dimensions and configuration Continued NOTES: 1. Dimensions are in inches. 2. Unless otherwise specified, tolerances are .016 on decimals. 3. Material: Plastic,
6、 molded, FED-STD-595/11136. Steel, commercial, shall be smooth and free from burrs. 4. Finish: Zinc plate, ASTM-B633 , type III, or cadmium plate, SAE-AMS-QQ-P-416, type III, with optional supplementary treatment per MIL-C-8514 or DOD-P-15328, black enamel, lusterless, FED-STD-595/37038 or semi glos
7、s, FED-STD-595/27038 or equivalent. 5. For design feature purposes, this standard takes precedence over procurement documents referenced herein. REQUIREMENTS Opening the guard shall not move the switch contacts. The guard shall remain in either open or closed position. Closing the guard shall move t
8、he switch lever to the center position from either the up or down position. Referenced documents shall be of the issue in effect on date of invitations for bid. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25214G 4 Referenced documents MIL-DTL-7
9、703 MIL-C-8514 ASTM-B633 SAE-AMS-QQ-P-416 FED-STD-595/11136 FED-STD-595/27038 FED-STD-595/37038 DOD-P-15328 The margins of this specification are marked with vertical lines to indicate where modifications from this revision were made. This was done as a convenience only and the Government assumes no
10、 liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations. Custodians: Preparing activity Army CR DLA CC Navy AS Air Force 85 (Project 5930-2010
11、-014) DLA CC Review activities: Air Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-