DLA MS25308 REV L-2011 SWITCH TOGGLE POSITIVE BREAK LEVER LOCK ENVIRONMENTALLY SEALED SCREW TERMINAL FOUR POLE 469 MOUNTING BUSHING 25 AMPERES.pdf

上传人:刘芸 文档编号:696538 上传时间:2019-01-02 格式:PDF 页数:4 大小:71.34KB
下载 相关 举报
DLA MS25308 REV L-2011 SWITCH TOGGLE POSITIVE BREAK LEVER LOCK ENVIRONMENTALLY SEALED SCREW TERMINAL FOUR POLE 469 MOUNTING BUSHING 25 AMPERES.pdf_第1页
第1页 / 共4页
DLA MS25308 REV L-2011 SWITCH TOGGLE POSITIVE BREAK LEVER LOCK ENVIRONMENTALLY SEALED SCREW TERMINAL FOUR POLE 469 MOUNTING BUSHING 25 AMPERES.pdf_第2页
第2页 / 共4页
DLA MS25308 REV L-2011 SWITCH TOGGLE POSITIVE BREAK LEVER LOCK ENVIRONMENTALLY SEALED SCREW TERMINAL FOUR POLE 469 MOUNTING BUSHING 25 AMPERES.pdf_第3页
第3页 / 共4页
DLA MS25308 REV L-2011 SWITCH TOGGLE POSITIVE BREAK LEVER LOCK ENVIRONMENTALLY SEALED SCREW TERMINAL FOUR POLE 469 MOUNTING BUSHING 25 AMPERES.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5930 INCH-POUND MS25308L 5 October 2011 SUPERSEDING MS25308K 4 September 1991 DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, POSITIVE BREAK, LEVER LOCK, ENVIRONMENTALLY SEALED, SCREW TERMINAL, FOUR POLE, .469 MOUNTING BUSHING, 25 AMPERES This specification is approved for use by all Departm

2、ents and Agencies of the Department of Defense. The requirements for acquiring the products described herein shall consist of this specification sheet and MIL-DTL-8834. Inches mm Inches mm .005 .012 .030 .032 .072 .138 .240 0.13 0.30 0.76 0.81 1.83 3.51 6.10 .250 .432 .469 .687 1.328 1.336 1.686 6.3

3、5 10.97 11.91 17.45 33.73 33.93 42.82 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .010 (0.25 mm) on decimals and 5 on angles. FIGURE 1. Dimensions and configuration - Continued. Provided by IHSNot for

4、 ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25308L 2 REQUIREMENTS: For hardware and terminal screw detail specifications, see appendix of MIL-DTL-8834. In the event of a conflict between the text of this specification and the references cited herein, the text of thi

5、s specification shall take precedence. The MS dash numbers supersede and are completely interchangeable with the superseded dash numbers. Example of Part or Identifying Numbers (PIN): MS25308-212 = on-off-on environmentally sealed switch. MS25308-272 = mom-on, off, mom-on environmentally sealed swit

6、ch Maximum weight: .2027 pound maximum (91.9 grams). Altitude requirements: 80,000 feet. 115 V ac 60 hertz electrical endurance tests are to be performed at room temperature and pressure. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE I. Detai

7、l requirements. MS dash no. Circuit made between terminals as indicated with the toggle lever in these positions 1/ Current capacity amperes per pole 28 volts dc 1/ Current capacity amperes per pole 115 volts 400 hertz 1/ Circuit capacity amperes per pole 115 volts 60 hertz 1/ Life low current level

8、 switching 30 mV Super- seded dash number Toggle sealed Environ- mentally sealed Opposite keyway side Center position Keyway side Lamp load circuit Resis-tive circuit Induc-tive circuit Lamp load circuit Resis-tive circuit Induc-tive circuit Lamp load circuit Resis-tive circuit Induc-tive circuit -2

9、12 on 2-3, 5-6, 8-9, 11-12 off on 1-2, 4-5, 7-8, 10-11 7 25 15 7 25 15 7 20 15 10 mV -211 -222 none off -221 -232 on 1-2, 4-5, 7-8, 10-11 -231 -242 off none -241 -262 none mom-on 1-2, 4-5, 7-8, 10-11 -261 -272 mom-on 2-3, 5-6, 8-9, 11-12 off -271 -282 none -281 -292 on 2-3, 5-6, 8-9,11-12 none mom-o

10、ff -291 -302 off mom-on 1-2, 4-5, 7-8, 10-11 -301 -312 on 2-3, 5-6, 8-9, 11-12 off -311 1/ Non-functional terminals shall not be supplied. 3MS25308LProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25308L 4 TABLE I. Detail requirements - Continued MS

11、 dash no. Current capacity amperes per pole 250 volts 60 hertz ac Current capacity amperes per pole 125 volts dc Circuit capacity amperes per pole 250 volts dc Life low current level switching 30 mV Super- seded dash number Toggle sealed Environ- mentally sealed Lamp load circuit Resis-tive circuit

12、Induc-tive circuit Lamp load circuit Resis-tive circuit Induc-tive circuit Lamp load circuit Resis-tive circuit Induc-tive circuit -212 10 7 750 mA - 500 mA - 10 mA -211 -222 -221 -232 -231 -242 -241 -262 -261 -272 -271 -282 -281 -292 -291 -302 -301 -312 -311 Referenced documents: MIL-DTL-8834 Chang

13、es from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity: Army - CR DLA CC Navy - AS Air Force - 85 (Project 5930-2011-087) DLA - CC Review activities: Army - AR, M

14、I Navy - EC Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • STAS 12619 20-1989 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENTS Sectional specification for fixed polyester dielectric capacitors《电气设备用定制电容器定值涤纶绝缘电容断面规格 》.pdf STAS 12619 20-1989 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENTS Sectional specification for fixed polyester dielectric capacitors《电气设备用定制电容器定值涤纶绝缘电容断面规格 》.pdf
  • STAS 12619 21-1990 Fixde capacitors for use in elecrtintc eqtilpmrnl POLYESTER DIELECTRIC PIXPtJ CAPACITORS Blank detail specification for quality wsesment level E《电气设备所用定值电容器.涤纶绝缘.pdf STAS 12619 21-1990 Fixde capacitors for use in elecrtintc eqtilpmrnl POLYESTER DIELECTRIC PIXPtJ CAPACITORS Blank detail specification for quality wsesment level E《电气设备所用定值电容器.涤纶绝缘.pdf
  • STAS 12620-1988 Brazing of metals FILLER METALS FOR BRAZING COPPER-PHOSPHORUS AND COPPER-PHOSPHORUS-SILVER ALLOYS 《金属铜焊 铜焊的填充金属铜磷和铜磷银合金 》.pdf STAS 12620-1988 Brazing of metals FILLER METALS FOR BRAZING COPPER-PHOSPHORUS AND COPPER-PHOSPHORUS-SILVER ALLOYS 《金属铜焊 铜焊的填充金属铜磷和铜磷银合金 》.pdf
  • STAS 12621-1988 OILS I'OR AIRCRAFT ( RBO-JET ENGINES AVI 8 oil and AVI 8A oil《飞行器用油(喷气式发动机AVI 8 和 AVI 8A 号油) 》.pdf STAS 12621-1988 OILS I'OR AIRCRAFT ( RBO-JET ENGINES AVI 8 oil and AVI 8A oil《飞行器用油(喷气式发动机AVI 8 和 AVI 8A 号油) 》.pdf
  • STAS 12622-1988 Cine malography UNDEREXPOSED MOTION- PICTURE FILMS REQUIRING FORCED DEVELOPMENT Marking and designation method《电影技术 需要强制冲洗的曝光型电影胶片 标记和指示方法 》.pdf STAS 12622-1988 Cine malography UNDEREXPOSED MOTION- PICTURE FILMS REQUIRING FORCED DEVELOPMENT Marking and designation method《电影技术 需要强制冲洗的曝光型电影胶片 标记和指示方法 》.pdf
  • STAS 12623-1988 Hydrostatic drives JOINTS WITH SEM10LAMPS Dimensions《静压驱动SEM 10灯接头尺寸 》.pdf STAS 12623-1988 Hydrostatic drives JOINTS WITH SEM10LAMPS Dimensions《静压驱动SEM 10灯接头尺寸 》.pdf
  • STAS 12624 1-1988 SPECIFIED METRO LOGICAL CHARACTERISTICS Terminology《特定地下铁路逻辑特征 术语 》.pdf STAS 12624 1-1988 SPECIFIED METRO LOGICAL CHARACTERISTICS Terminology《特定地下铁路逻辑特征 术语 》.pdf
  • STAS 12624 2-1988 SPECIFIED METROLOGICAL CIIAR ACTERISTICS Formulae and rules for establishment of the static metrological charaeleristics《特定计量学特性 静态计量学特性确立所需公式及规则 》.pdf STAS 12624 2-1988 SPECIFIED METROLOGICAL CIIAR ACTERISTICS Formulae and rules for establishment of the static metrological charaeleristics《特定计量学特性 静态计量学特性确立所需公式及规则 》.pdf
  • STAS 12625-1988 SOLAR COLLECTORS FLAT SOLAR COLLECTORS USING GASES OR LIQUIDS AS TRANS- FER FLUID Checking up methods of mechanical characteristics《太阳能集热器 平板太阳能集热器使用气体或液体作为转换流体 机械特.pdf STAS 12625-1988 SOLAR COLLECTORS FLAT SOLAR COLLECTORS USING GASES OR LIQUIDS AS TRANS- FER FLUID Checking up methods of mechanical characteristics《太阳能集热器 平板太阳能集热器使用气体或液体作为转换流体 机械特.pdf