DLA MS27408 REV E-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED LEVER LOCK.pdf

上传人:visitstep340 文档编号:696774 上传时间:2019-01-02 格式:PDF 页数:4 大小:75.48KB
下载 相关 举报
DLA MS27408 REV E-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED LEVER LOCK.pdf_第1页
第1页 / 共4页
DLA MS27408 REV E-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED LEVER LOCK.pdf_第2页
第2页 / 共4页
DLA MS27408 REV E-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED LEVER LOCK.pdf_第3页
第3页 / 共4页
DLA MS27408 REV E-2011 SWITCH TOGGLE TWO POLE ENVIRONMENTALLY SEALED LEVER LOCK.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5930 INCH-POUND MS27408E 18 April 2011 SUPERSEDING MS27408D 28 September 1987 DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, TWO POLE, ENVIRONMENTALLY SEALED, LEVER LOCK This specification is approved for use by all Departments and Agencies of the Department of Defense. The complete require

2、ments for acquiring the switch described herein shall consist of this specification and the latest issue of MIL-DTL-3950. FIGURE1. Dimensions and configuration Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27408E 2 NOTES: 1. Dimensions are inches

3、 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .020 (0.51 mm) for two place decimals and .005 (0.13 mm) for three place decimals. 4. For hardware and terminal screw detail specifications, see appendix of MIL-DTL-3950. 5. Part number exampl

4、e: MS27408-1A (Locking combination A). 6. In the event of a conflict between the text of this standard and the reference cited herein, the text of this standard shall take precedence. FIGURE1. Dimensions and configuration Continued REQUIREMENTS All switches on this standard are designed so that the

5、movement of the switch mechanism is opposite to that of the toggle lever. Locking arrangement: Positive locking shall be accomplished and shall prevent motion of the toggle lever until the locking mechanism is manually released. The force required to release the locking mechanism shall be 3 to 5 pou

6、nds. The locking means at the top of the toggle bushing shall be capable of withstanding a torque of 20 inch-pounds applied in both directions immediately following the humidity test. Maximum weight is 0.20 pound. Electrical rating: See table I. Inches mm Inches mm .005 0.13 .38 9.7 .008 0.20 .42 10

7、7 .012 0.30 .432 10.97 .020 0.51 .47 11.9 .060 1.52 .910 23.11 .076 1.93 1.05 26.7 .130 3.30 1.10 27.9 .25 6.4 1.140 28.93 .26 6.6 1.340 34.04 1.370 34.80 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27408E 3 FIGURE 2. Locking Combinations. Pro

8、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27408E 4 TABLE I Detail Requirements. Referenced documents MIL-DTL-3950 Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the ch

9、anges. Custodians: Preparing activity Army CR DLA CC Navy AS Air Force 85 (Project 5930-2011-052) DLA CC Review activities Army AR, AV, MI Navy EC, MC Air Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibili

10、ties can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . MS Part number Available locking combinations Circuit with toggle lever in Current capacity (amperes) 28 volts dc Current capacity (amperes) 115 volts, 60 and 40

11、0 hertz ac Keying side Center Opposite keying side Lamp-load circuit Resistive circuit Inductive circuit Lamp-load circuit Resistive circuit Inductive circuit MS27408-1 All 1-2 On 4-5 2-3 On 4-5 2-3 On 5-6 7 20 15 4 15 15 MS27408-2 E,F,K,L,M,N Mom. 1-2 On 4-5 2-3 On 4-5 2-3 On 5-6 5 18 10 2 11 8 MS2

12、7408-3 E,L,N Mom. 1-2 On 4-5 2-3 On 4-5 Mom. 2-3 On 5-6 MS27408-4 All 1-2 On 4-5 1-2 On 5-6 2-3 On 5-6 7 20 15 4 15 15 MS27408-5 E,F,K,L,M,N Mom. 1-2 On 4-5 1-2 On 5-6 2-3 On 5-6 5 18 10 2 11 8 MS27408-6 E,L,N Mom. 1-2 On 4-5 1-2 On 5-6 Mom. 2-3 On 5-6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN VDE 0266-2000 Power cables with improved characteristics in the case of fire - Nominal voltages U U 0 6 1 kV《改良耐火特性的电力电缆 标称电压UO U 0 6 1kV》.pdf DIN VDE 0266-2000 Power cables with improved characteristics in the case of fire - Nominal voltages U U 0 6 1 kV《改良耐火特性的电力电缆 标称电压UO U 0 6 1kV》.pdf
  • DIN VDE 0271 Berichtigung 1-2008 Power cables - Specifications for power cables 0 6 1 kV and above for special applications Corrigenda to DIN VDE 0271 (VDE 0271) 2007-01《电力电缆 专用0 6.pdf DIN VDE 0271 Berichtigung 1-2008 Power cables - Specifications for power cables 0 6 1 kV and above for special applications Corrigenda to DIN VDE 0271 (VDE 0271) 2007-01《电力电缆 专用0 6.pdf
  • DIN VDE 0271-2007 Power cables - Specifications for power cables 0 6 1 kV and above for special applications《电力电缆 专用0 6 1kV及以上的电力电缆规范》.pdf DIN VDE 0271-2007 Power cables - Specifications for power cables 0 6 1 kV and above for special applications《电力电缆 专用0 6 1kV及以上的电力电缆规范》.pdf
  • DIN VDE 0276-1000-1995 Power cables - Part 1000 Current-carrying capacity general conversion factors《电力电缆 第1000部分 电流负载容量、总则、换算系数》.pdf DIN VDE 0276-1000-1995 Power cables - Part 1000 Current-carrying capacity general conversion factors《电力电缆 第1000部分 电流负载容量、总则、换算系数》.pdf
  • DIN VDE 0276-603-2010 Power cables - Part 603 Distribution cables of rated voltage 0 6 1 kV German version HD 603 S1 1994 A3 2007 parts 0 1 3-G and 5-G《电力电缆 第603部分 额定电压 0 6 1kV的配线电.pdf DIN VDE 0276-603-2010 Power cables - Part 603 Distribution cables of rated voltage 0 6 1 kV German version HD 603 S1 1994 A3 2007 parts 0 1 3-G and 5-G《电力电缆 第603部分 额定电压 0 6 1kV的配线电.pdf
  • DIN VDE 0276-604-2008 Power cables - Part 604 0 6 1 kV power cables with special fire performance for use in power stations German version HD 604 S1 1994 + A1 1997 + A2 2002 + A3 2.pdf DIN VDE 0276-604-2008 Power cables - Part 604 0 6 1 kV power cables with special fire performance for use in power stations German version HD 604 S1 1994 + A1 1997 + A2 2002 + A3 2.pdf
  • DIN VDE 0276-605-2009 Electric cables - Additional test methods German version HD 605 S2 2008《电缆 附加试验方法 德文版本HD 605 S2 2008》.pdf DIN VDE 0276-605-2009 Electric cables - Additional test methods German version HD 605 S2 2008《电缆 附加试验方法 德文版本HD 605 S2 2008》.pdf
  • DIN VDE 0278-629-1-2009 Test requirements on accessories for use on power cables of rated voltage from 3 6 6(7 2) kV up to 20 8 36(42) kV - Part 1 Cables with extruded insulation G.pdf DIN VDE 0278-629-1-2009 Test requirements on accessories for use on power cables of rated voltage from 3 6 6(7 2) kV up to 20 8 36(42) kV - Part 1 Cables with extruded insulation G.pdf
  • DIN VDE 0278-629-2-2009 Test requirements on accessories for use on power cables of rated voltage from 3 6 6(7 2) kV up to 20 8 36(42) kV - Part 2 Cables with impregnated paper ins.pdf DIN VDE 0278-629-2-2009 Test requirements on accessories for use on power cables of rated voltage from 3 6 6(7 2) kV up to 20 8 36(42) kV - Part 2 Cables with impregnated paper ins.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1