DLA MS27789 REV D-2005 SWITCH TOGGLE FOUR POLE ENVIRONMENTALLY SEALED LEVER LOCK INTEGRATED WIRE TERMINALS《集成电线终端杠杆锁 环保密封式四极肘节开关》.pdf

上传人:testyield361 文档编号:696886 上传时间:2019-01-02 格式:PDF 页数:5 大小:77.81KB
下载 相关 举报
DLA MS27789 REV D-2005 SWITCH TOGGLE FOUR POLE ENVIRONMENTALLY SEALED LEVER LOCK INTEGRATED WIRE TERMINALS《集成电线终端杠杆锁 环保密封式四极肘节开关》.pdf_第1页
第1页 / 共5页
DLA MS27789 REV D-2005 SWITCH TOGGLE FOUR POLE ENVIRONMENTALLY SEALED LEVER LOCK INTEGRATED WIRE TERMINALS《集成电线终端杠杆锁 环保密封式四极肘节开关》.pdf_第2页
第2页 / 共5页
DLA MS27789 REV D-2005 SWITCH TOGGLE FOUR POLE ENVIRONMENTALLY SEALED LEVER LOCK INTEGRATED WIRE TERMINALS《集成电线终端杠杆锁 环保密封式四极肘节开关》.pdf_第3页
第3页 / 共5页
DLA MS27789 REV D-2005 SWITCH TOGGLE FOUR POLE ENVIRONMENTALLY SEALED LEVER LOCK INTEGRATED WIRE TERMINALS《集成电线终端杠杆锁 环保密封式四极肘节开关》.pdf_第4页
第4页 / 共5页
DLA MS27789 REV D-2005 SWITCH TOGGLE FOUR POLE ENVIRONMENTALLY SEALED LEVER LOCK INTEGRATED WIRE TERMINALS《集成电线终端杠杆锁 环保密封式四极肘节开关》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5930 MS27789D 13 September 2005 SUPERSEDING MS27789C 28 September 1987 DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, FOUR POLE, ENVIRONMENTALLY SEALED, LEVER LOCK, INTEGRATED WIRE TERMINALS This specification is approved for use by all Departments and Agencies of the Department of Defense.

2、 The complete requirements for acquiring the switch described herein shall consist of this specification and the latest issue of MIL-DTL-3950. FIGURE1. Dimensions and configuration INCH-POUNDINACTIVE FOR NEW DESIGN AFTER 30 AUGUST 2005 Provided by IHSNot for ResaleNo reproduction or networking permi

3、tted without license from IHS-,-,-MS27789D 2FIGURE 1 Dimensions and configuration- Continued Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27789D 3NOTES: 1. Dimensions are inches. 2. Metric equivalents are given for general information only. 3. U

4、nless otherwise specified, tolerance is .020 (0.51 mm) for two place decimals and .005 (0.13 mm) for three place decimals. 4. For hardware detail specifications see appendix of MIL-DTL-3950. 5. Contact installing/removal tool in accordance with MIL-I-81969. 6. Grommet sealing plug in accordance with

5、 MS27488A20. 7. Sealing plugs may be used in nonfunctional grommet holes. 8. Sealing grommet shall seal on a smooth wire insulation of .040 (1.02 mm) to .083 (2.11 mm) 9. Terminal shall adequately accept a wire contact within dimensional limits of SAE-AS39029. 10. The terminal end of switch shall be

6、 color coded red to indicate contact size. 11. Direction of internal mechanism movement is opposite to the direction of the toggle movement. 12. Part number example: MS27789-21A ( locking combination A) 13. In the event of a conflict between the text of this standard and the reference cited herein,

7、the text of this standard shall take precedence. FIGURE1. Dimensions and configuration- Continued TEST REQUIREMENTS: Test shall be performed in accordance with MIL-DTL-3950 except: During all tests, switch shall be fully wired with appropriate wire and terminal contacts. Contact voltage drop- the co

8、ntact voltage drop with two terminals and the switch contact in series shall not exceed 8 millivolts measured from one wire contact through the contacts to the other wire contacts. DETAIL REQUIREMENTS: Locking arrangement: Positive locking shall be accomplished and shall prevent motion of the toggle

9、 lever until the locking mechanism is manually released. The force required to release the locking mechanism shall be 3 to 5 pounds. The locking means at the top of the toggle bushing shall be capable of withstanding a torque of 20 inch-pounds applied in both directions immediately following the hum

10、idity test. Weight: .227 pound maximum. Inches mm Inches mm .005 0.13 .432 10.97 .008 0.20 .469 11.91 .012 0.30 .47 11.9 .020 0.51 1.05 26.7 .060 1.52 1.140 28.96 .076 1.93 1.340 34.04 .38 9.7 1.660 42.16 .42 10.7 1.706 43.33 Provided by IHSNot for ResaleNo reproduction or networking permitted witho

11、ut license from IHS-,-,-MS27789D 4Referenced documents MIL-DTL-3950 MIL-I-81969 MS27488 SAE-AS39029 Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity Army CR DLA -CC Navy - AS (Proj

12、ect 5930-2005-003) Air Force - 11 DLA C Circuit with Toggle Lever In Current capacity (amperes) 28 volts DC Current capacity(amperes) 115 volts, 60 and 400 Hertz AC MS part No. Available locking combinations Keying side center Opposite keying side Lamp-Load circuit Resistive circuit Inductive circui

13、t Lamp-Load circuit Resistive circuit Inductive circuit MS27789-1 ALL 1-2 4-5 7-8 on 10-11 2-3 4-5 7-8 on 11-12 2-3 5-6 8-9 On 11-12 5 7.5 7.5 4 7.5 7.5 MS27789-2 E, F, K, L, M, N 1-2 Mom. 4-5 7-8 on 10-11 2-3 4-5 7-8 on 11-12 2-3 5-6 8-9 on 11-12 MS27789-3 E, L, N 1-2 Mom. 4-5 7-8 on 10-11 2-3 4-5

14、7-8 on 11-12 2-3 Mom. 5-6 8-9 on 11-12 4 7.5 7.5 2 7.5 7.5 MS27789-21 ALL 1-2 7-8 4-5 on 10-11 Off 2-3 8-9 8-9 on 11-12 MS27789-22 D, F, G Off None 2-3 8-9 5-6 on 11-12 MS27789-23 D, F, G 1-2 Mom. 7-8 4-5 on 10-11 None 2-3 8-9 5-6 on 11-12 MS27789-24 E, F, K, M None Off 2-3 8-9 5-6 on 11-12 5 7.5 7.

15、5 4 7.5 7.5 MS27789-25 F None Mom. Off 2-3 8-9 5-6 on 11-12 MS27789-26 F 1-2 Mom. 7-8 4-5 on 10-11 None 2-3 8-9 5-6 on 11-12 MS27789-27 E, L, N 1-2 Mom. 7-8 4-5 on 10-11 Off 2-3 8-9 5-6 on 11-12 MS27789-28 E 1-2 Mom. 7-8 4-5 on 10-11 Off None MS27789-29 F Mom. Off None 2-3 8-9 5-6 on 11-12 MS27789-3

16、0 F 1-2 Mom. 7-8 4-5 on 10-11 None Off MS27789-31 E, F, K, L, M, N 1-2 Mom. 7-8 4-5 on 10-11 off 2-3 8-9 5-6 on 11-12 MS27789-32 E None 1-2 7-8 4-5 on 10-11 2-3 Mom. 8-9 5-6 on 11-12 4 7.5 7.5 2 7.5 7.5 MS27789-33 E, F, K, M None 1-2 7-8 4-5 On 10-11 2-3 8-9 5-6 on 11-12 5 7.5 7.5 4 7.5 7.5 Provided

17、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS27789D 5Review activities Army AR, AV, CR4 Navy EC, MC Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil/ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1