1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Added device type 02. Updated drawing to the reflect current requirements. -sld 06-01-05 Raymond Monnin B Added device type 03. -sld 08-02-20 Robert M. Heber C Added radiation hardness assurance requirements. Paragraph 1.3, corrected the positive

2、, negative, and VREFvoltages from “+20 V and -20 V“ to “+16.5 V and -16.5 V“. Table I; sheet 6, under the Group A subgroups column added footnote 4 for the Address input currents and Enable input current tests. Table I; sheet 7, under the Group A subgroups column added footnote 4 for all current tes

3、ts. Updated drawing paragraphs. -sld 13-04-30 Charles F. Saffle REV SHEET REV C C C C C C C C C SHEET 15 16 17 18 19 20 21 22 23 REV STATUS REV C C C C C C C C C C C C C C OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Greg Cecil DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990

4、 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Greg Cecil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Raymond Monnin MICROCIRCUIT, HYBRID, LINEAR, 48 CHANNEL, ANALOG MULTIPLEXER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 03-03-1

5、3 AMSC N/A REVISION LEVEL C SIZE A CAGE CODE 67268 5962-03234 SHEET 1 OF 23 DSCC FORM 2233 APR 97 5962-E398-13Provided by IHSNot for Resale-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1

6、Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are

7、 reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 F 03234 01 K X C Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Ra

8、diation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device

9、type Generic number Circuit function 01 ACT8502 48 channel, voltage and current analog multiplexer, high impedance analog input with ESD protection 02 ACT8506 48 channel, voltage and current analog multiplexer, high impedance analog input 03 ACT8503 48 channel, analog multiplexer, high impedance ana

10、log input with ESD protection 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Li

11、sting (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where

12、 non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but m

13、ay not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the

14、acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided

15、by IHSNot for Resale-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator T

16、erminals Package style X See figure 1 96 Ceramic quad flat pack 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Positive supply voltage between +VCCand GND +16.5 V dc Negative supply voltage between -VEEand GND -16.5 V dc VREFto GND +16.5 V

17、 dc Digital input overvoltage range: VEN(pins 5, 6, 91, and 92) . ( GND - 4)V VA(pins 1, 3, 93, and 95). ( GND - 4)V VB(pins 2, 4, 94, and 96). ( GND - 4)V Analog input overvoltage range: Device types 01and 03 -18 V dc VS +18 V dc Device type 02 . -25 V dc VS +25 V dc Power dissipation (PD): Device

18、types 01 and 02 . 120 mW Device type 03 . 60 mW Thermal resistance junction-to-case (JC) . 10C/W 2/ Storage temperature range . -55C to +150C Lead temperature (soldering, 10 seconds) . +300C 1.4 Recommended operating conditions. Positive supply voltage (+VCC) +15 V dc 3/ Negative supply voltage (-VE

19、E) -15 V dc 3/ VREF. +5 V dc 3/ Logic low level voltage (VAL) . +0.8 V dc Logic high level voltage (VAH) . +4.0 V dc Case operating temperature range (TC) -55C to +125C 1.5 Radiation features. 4/ Maximum Total Ionizing Dose (TID) (dose rate = 50 - 300 rad(Si)/s) . 300 krad(Si) 5/ 6/ Enhanced Low Dos

20、e Rate Sensitvity (ELDRS) 150 krad(Si) 5/ Single Event Phenomenon (SEP) effective linear energy transfer (LET): Single Event Latchup (SEL) Immune 5/ Single Event Upset (SEU) . 86 MeV-cm2/mg 7/ Single Event Transient (SET) 86 MeV-cm2/mg 7/ 1/ Stresses above the absolute maximum ratings may cause perm

21、anent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Based on the maximum power dissipation spread over the multiplexer die. 3/ Recommended power supply turn on sequence : +VCC, -VEE, followed by VREF. 4/ See section 4.3.5 for the ma

22、nufacturers radiation hardness assurance analysis and testing. 5/ The only active element in these devices are purchased as SMD 5962F9563002V9A which assures TID, ELDRS, and SEL. 6/ The package in this drawing is a larger version of the same type (flat package) as the one in SMD 5962-95630, the lid

23、underside is nickel plate (no gold), and RGA data shows negligible amounts of hydrogen. 7/ SEU and SET testing performed at 86 MeV-cm2/mg with no upsets or single event transients. These devices will be re-tested after design or process changes that can affect RHA response of these devices. Provided

24、 by IHSNot for Resale-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 4 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handboo

25、ks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDA

26、RDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available o

27、nline at http:/quicksearch.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes pre

28、cedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Co

29、mpliance with MIL-PRF-38534 shall include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the p

30、erformance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, con

31、struction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.2.3 Truth table(s). The tr

32、uth table(s) shall be as specified on figure 3. 3.2.4 Switching waveform(s). The switching waveform(s) shall be as specified on figure 4. 3.2.5 Block diagram. The block diagram shall be as specified on figure 5. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the elect

33、rical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in ta

34、ble I. 3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. Provided by IHSNot for Resale-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A

35、5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 5 DSCC FORM 2234 APR 97 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from th

36、e initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufact

37、urer and be made available to the preparing activity (DLA Land and Maritime -VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DLA Land and

38、Maritime -VA shall affirm that the manufacturers product meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. Provided by I

39、HSNot for Resale-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 6 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ 2/ -55C TC +125C unless otherwise specified Group A subgroups

40、 Device type Limits Unit Min Max Supply currents +ICCVEN(0-63)= VA(0-3)A= VA(0-3)B= 0 1,2,3 01,02 0.3 3 mA 03 0.3 1.5 -IEE VEN(0-63)= VA(0-3)A= VA(0-3)B= 0 1,2,3 01,02 -3 -0.3 mA 03 -1.5 -0.3 +ISBY VEN(0-63)= 4 V, VA(0-3)A= VA(0-3)B= 0 3/ 1,2,3 01,02 0.3 3 mA 03 0.3 1.5 -ISBY VEN(0-63)= 4 V, VA(0-3)

41、A= VA(0-3)B= 0 3/ 1,2,3 01,02 -3.0 -0.3 mA 03 -1.5 -0.3 Address input currents IAL(0-3)VA= 0 V 2/ 1,2,3 4/ 01,02 -6 6 A 03 -3 3 IAH(0-3) VA= 5 V 2/ 1,2,3 4/ 01,02 -6 6 A 03 -3 3 Enable input current IENL(0-15) VEN(0-15)= 0 V 1,2,3 4/ 01,02 -2 2 A 03 -1 1 IENH(0-15)VEN(0-15)= 5 V 1,2,3 4/ 01,02 -2 2

42、A 03 -1 1 IENL(16-31)VEN16-31)= 0 V 1,2,3 4/ 01,02 -2 2 A 03 -1 1 IENH(16-31)VEN(16-31)= 5 V 1,2,3 4/ 01,02 -2 2 A 03 -1 1 IENL(32-47)VEN(32-47)= 0 V 1,2,3 4/ 01,02 -2 2 A 03 -1 1 IENH(32-47)VEN(32-47)= 5 V 1,2,3 4/ 01,02 -2 2 A 03 -1 1 See footnotes at end of table. Provided by IHSNot for Resale-,-

43、,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 7 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions 1/ 2/ -55C TC +125C unless otherwise specified Group A subgroups Device

44、 type Limits Unit Min Max Positive input leakage current (CH0-CH47) +ISOFFOUTPUT(ALL) VIN= +10 V, VEN= 4 V, output and all unused inputs = -10 V 5/ 6/ 1,2,3 4/ 01,03 -100 +700 nA 1 02 -20 +20 2,3 4/ -200 +200 +ISOFFCURRENT(ALL) VIN= +10 V, VEN= 4 V, output and all unused inputs = -10 V 5/ 6/ 1,2,3 4

45、/ 01 -100 +700 nA 1 02 -20 +20 2,3 4/ -200 +200 Negative input leakage current (CH0-CH47) -ISOFFOUTPUT(ALL) VIN= -10 V, VEN= 4 V, output and all unused inputs = +10 V 5/ 6/ 1,2,3 4/ 01,03 -100 +700 nA 1 02 -20 +20 2,3 4/ -200 +200 -ISOFFCURRENT(ALL) VIN= -10 V, VEN= 4 V, output and all unused inputs

46、 = +10 V 5/ 6/ 1,2,3 4/ 01 -100 +700 nA 1 02 -20 +20 2,3 4/ -200 +200 Output leakage current outputs (pins 25, 68 and 70) Currents (pins 26, 67, and 69) +IDOFFOUTPUT(ALL) VIN= +10 V, VEN= 4 V, output and all unused inputs = -10 V 6/ 7/ 1,2,3 4/ All -100 +100 nA +IDOFFCURRENT(ALL) VIN= +10 V, VEN= 4

47、V, output and all unused inputs = -10 V 6/ 7/ 1,2,3 4/ 01.02 -100 +100 nA -IDOFFOUTPUT(ALL) VIN= -10 V, VEN= 4 V, output and all unused inputs = +10 V 6/ 7/ 1,2,3 4/ All -100 +100 nA -IDOFFCURRENT(ALL) VIN= -10 V, VEN= 4 V, output and all unused inputs = +10 V 6/ 7/ 1,2,3 4/ 01,02 -100 +100 nA See f

48、ootnotes at end of table. Provided by IHSNot for Resale-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-03234 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 8 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions 1/ 2/ -55C TC +125C unless otherwise specified Group A subgroups Device type Limits Unit Min Max Input clamped voltage (CH0-CH47) +VCLMP(0-47) VE

展开阅读全文
相关资源
猜你喜欢
  • DIN ETS 300276-1994 Network Aspects (NA) - Metropolitan Area Network (MAN) - Physical Layer Convergence Procedure (PLCP) for 622 080 Mbit s CCITT Recommendations G 707 G 708 and G .pdf DIN ETS 300276-1994 Network Aspects (NA) - Metropolitan Area Network (MAN) - Physical Layer Convergence Procedure (PLCP) for 622 080 Mbit s CCITT Recommendations G 707 G 708 and G .pdf
  • DIN ETS 300277-1994 Network Aspects (NA) Metropolitan Area Network (MAN) - Physical Layer Convergence Procedure (PLCP) for 622 080 Mbit s CCITT Recommendations G 707 G 708 and G 70.pdf DIN ETS 300277-1994 Network Aspects (NA) Metropolitan Area Network (MAN) - Physical Layer Convergence Procedure (PLCP) for 622 080 Mbit s CCITT Recommendations G 707 G 708 and G 70.pdf
  • DIN ETS 300278-1994 Network Aspects (NA) - Support of existing services with guaranteed constant bit rate and specified transfer delay on Metropolitan Area Network (MAN) English ve.pdf DIN ETS 300278-1994 Network Aspects (NA) - Support of existing services with guaranteed constant bit rate and specified transfer delay on Metropolitan Area Network (MAN) English ve.pdf
  • DIN ETS 300280 A1-1996 Terminal Equipment (TE) - Facsimile group 4 class 1 equipment on the Integrated Services Digital Network (ISDN) - Terminal testing English version ETS 300280.pdf DIN ETS 300280 A1-1996 Terminal Equipment (TE) - Facsimile group 4 class 1 equipment on the Integrated Services Digital Network (ISDN) - Terminal testing English version ETS 300280.pdf
  • DIN ETS 300280-1994 Terminal equipment (TE) - Facsimile group 4 class 1 equipment in the Integrated Services Digital Network (ISDN) - Terminal testing English version ETS 300280 19.pdf DIN ETS 300280-1994 Terminal equipment (TE) - Facsimile group 4 class 1 equipment in the Integrated Services Digital Network (ISDN) - Terminal testing English version ETS 300280 19.pdf
  • DIN ETS 300282-1995 Satellite Earth Stations and systems (SES) - Network Control Facilities (NCFs) Land Mobile Earth Stations (LMESs) operatinng in the 1 5 1 6 GHz and 11 12 14 GHzs.pdf DIN ETS 300282-1995 Satellite Earth Stations and systems (SES) - Network Control Facilities (NCFs) Land Mobile Earth Stations (LMESs) operatinng in the 1 5 1 6 GHz and 11 12 14 GHzs.pdf
  • DIN ETS 300283-1994 Business TeleCommunications (BTC) - Planning of loudness rating and echo values for private networks digitally connected to the public network English version E.pdf DIN ETS 300283-1994 Business TeleCommunications (BTC) - Planning of loudness rating and echo values for private networks digitally connected to the public network English version E.pdf
  • DIN ETS 300284-1996 Integrated Services Digital Network (ISDN) - User-to-User Signalling (UUS) supplementary service - Service description English version ETS 300284 1996《综合服务数字网(I.pdf DIN ETS 300284-1996 Integrated Services Digital Network (ISDN) - User-to-User Signalling (UUS) supplementary service - Service description English version ETS 300284 1996《综合服务数字网(I.pdf
  • DIN ETS 300287-1-1997 Integrated Services Digital Network (ISDN) - Signalling System No 7 - Transaction Capabilities (TC) version 2 - Part 1 Protocol specification (ITU-T Recommend.pdf DIN ETS 300287-1-1997 Integrated Services Digital Network (ISDN) - Signalling System No 7 - Transaction Capabilities (TC) version 2 - Part 1 Protocol specification (ITU-T Recommend.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1