DLA SMD-5962-09209 REV A-2011 MICROCIRCUIT HYBRID LINEAR POSITIVE LOW DROPOUT FIXED VOLTAGE REGULATOR.pdf

上传人:medalangle361 文档编号:698434 上传时间:2019-01-02 格式:PDF 页数:12 大小:124.51KB
下载 相关 举报
DLA SMD-5962-09209 REV A-2011 MICROCIRCUIT HYBRID LINEAR POSITIVE LOW DROPOUT FIXED VOLTAGE REGULATOR.pdf_第1页
第1页 / 共12页
DLA SMD-5962-09209 REV A-2011 MICROCIRCUIT HYBRID LINEAR POSITIVE LOW DROPOUT FIXED VOLTAGE REGULATOR.pdf_第2页
第2页 / 共12页
DLA SMD-5962-09209 REV A-2011 MICROCIRCUIT HYBRID LINEAR POSITIVE LOW DROPOUT FIXED VOLTAGE REGULATOR.pdf_第3页
第3页 / 共12页
DLA SMD-5962-09209 REV A-2011 MICROCIRCUIT HYBRID LINEAR POSITIVE LOW DROPOUT FIXED VOLTAGE REGULATOR.pdf_第4页
第4页 / 共12页
DLA SMD-5962-09209 REV A-2011 MICROCIRCUIT HYBRID LINEAR POSITIVE LOW DROPOUT FIXED VOLTAGE REGULATOR.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Paragraph 1.5, correct maximum total dose available from 300 Krads (Si) to 300 Krads (Si). Paragraph 4.3.5.1a, last sentence, correct 5962F0824601 to 5962F0921001. Update boilerplate paragraphs. -gz 11-04-05 Charles F. Saffle REV SHET REV SHET RE

2、V STATUS REV A A A A A A A A A A A OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A PREPARED BY Gary Zahn DLA LAND AND MARITIME STANDARD MICROCIRCUIT DRAWING CHECKED BY Greg Cecil COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL APPROVED BY Charles F. Saffle

3、MICROCIRCUIT, HYBRID, LINEAR, POSITIVE, DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 09-08-04 LOW DROPOUT, FIXED VOLTAGE REGULATOR AMSC N/A REVISION LEVEL A SIZE A CAGE CODE 67268 5962-09209 SHEET 1 OF 11 DSCC FORM 2233 APR 97 5962-E197-11Provided by IHSNot for ResaleN

4、o reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in p

5、aragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following e

6、xample: 5962 F 09209 01 K X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet t

7、he MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device types. The device types identify the circuit function as follows: Device type Generic number Circuit function 01 MSK 5825-2.5RH Radiation hardened, 3.5 A

8、, 2.5 V voltage regulator 02 MSK 5825-3.3RH Radiation hardened, 3.5 A, 3.3 V voltage regulator 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Cer

9、tification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality

10、class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacture

11、r specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) mus

12、t be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified f

13、low. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 3 DSCC FORM 2234 APR 97 1.2

14、.4 Case outlines. The case outlines are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 8 Flat pack with gull wing leads, glass sealed Y See figure 1 8 Flat pack with straight leads, glass sealed 1.2.5 Lead finish. The lead f

15、inish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage (VIN) +7.0 V dc Output current 3.5 A 2/ Junction temperature (TJ) +150C Thermal resistance, junction-to-case (JC), TC= +125C . 6.5C/W Storage temperature -65C to +150C Lead temperature (soldering, 10 seconds

16、) +300C 1.4 Recommended operating conditions. Input voltage range (VIN) +4.5 V dc to +6.5 V dcCase operating temperature range (TC). -55C to +125C 1.5 Radiation features. Maximum total dose available 300 Krads (Si) 3/ 4/ 5/ 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handboo

17、ks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, G

18、eneral Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microci

19、rcuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this draw

20、ing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extend

21、ed operation at the maximum levels may degrade performance and affect reliability. 2/ Output current limit is dependent on the value of VIN- VOUT. 3/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radiation end-point limits for the n

22、oted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition A. Dose rate shall be in accordance with MIL-STD-883, method 1019, condition A. 4/ Bipolar device types may degrade from displacement damage from radiation which could affect RHA levels. These

23、device types have not been characterized for displacement damage. 5/ See figure 3. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET

24、4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device man

25、ufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, t

26、he modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outlines. The c

27、ase outlines shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.2.3 Radiation exposure circuits. The radiation exposure circuits shall be as specified on figure 3. 3.3 Electrical performance characteristics

28、. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electr

29、ical tests for each subgroup are defined in table I. 3.5 Marking of devices. Marking of devices shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the

30、general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summar

31、y of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made available to the preparing activity (DLA Land and Maritime-VA) upon request. 3.7 Certificate of compliance. A certific

32、ate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime-VA shall affirm that the manufacturers product meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate

33、of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified in the device

34、 manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND

35、 MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ 2/ 3/ -55C TC+125C unless otherwise specified Group A subgroups Device type Limits Unit Min MaxOutput voltage VOUTVIN= 5.0 V, IOUT= 1.5 A 1 01

36、 2.475 2.525 V 02 3.267 3.333 4.5 V VIN 5.5 V 50 mA IOUT 3.0 A 1,2,3 01 2.375 2.625 02 3.135 3.465 M,D,P,L,R,F 1/ 1 01 2.375 2.625 02 3.135 3.465 Dropout voltage VDOIOUT= 3.0 A 1,2,3 01,02 0.5 V Current limit 4/ IOUTVIN= 5.0 V 1,2,3 01,02 3.0 A Shutdown threshold VSTVIN= 5.0 V 1,2,3 01,02 1.0 1.6 V

37、Output voltage at shutdown VOUTSD VIN= VSHDN= 5.0 V, IOUT= 50 mA 1,2,3 01,02 -0.1 +0.1 V 1/ Device types 01 and 02 have been characterized through all levels M, D, P, L, R, F of irradiation and tested to 1.5 times at the F level. Pre and post irradiation values are identical unless otherwise specifi

38、ed in table I. When performing post irradiation electrical measurements for any RHA level, TC= +25C. 2/ Unless otherwise specified, VIN= 5.0 V, VSHUTDOWN= 0 V, and IOUT= 50 mA. 3/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radiat

39、ion end-point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, method 1019, condition A. 4/ Current limit is dependent upon the value of VIN. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD

40、MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 6 DSCC FORM 2234 APR 97 Case outline X. Symbol Millimeters InchesMin Max Min Max A - 4.83 - .190 A1 0.076 0.18 .003 .007 b 0.58 0.69 .023 .027 D/E 18.92 19.18 .745 .755 D1 27.18 27.69 1.070

41、1.090 e 2.54 TYP .100 TYP e1 7.49 7.75 .295 .305 L 2.79 3.81 .110 .150 L1 0.76 1.27 .030 .050 R 0.76 REF .030 REF S1 5.21 6.22 .205 .245 NOTES: 1. A1 is measured from the bottom of the lead to the bottom of the package. 2. Pin 1 is indicated by the ESD marking on the package. Pin numbers are for ref

42、erence only. 3. The U. S. Government preferred system of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units shall take precedence. 4. Case outline X weight:

43、5.5 grams typical. FIGURE 1. Case outlines. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 7 DSCC FORM 2234 APR 97 Case outline Y.

44、 Symbol Millimeters InchesMin Max Min Max A - 4.57 - .180 A1 1.78 2.03 .070 .080 b 0.58 0.69 .023 .027 D/E 18.92 19.18 .745 .755 e 2.54 TYP .100 TYP e1 7.49 7.75 .295 .305 L 10.16 - .400 - S1 5.21 6.22 .205 .245 NOTES: 1. Pin 1 is indicated by the ESD class marking. Pin numbers are for reference. 2.

45、 The U. S. Government preferred system of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units shall take precedence. 3. Pin numbers are for reference only. 4.

46、 Case outline Y weight: 5.8 grams typical. FIGURE 1. Case outlines - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 8 D

47、SCC FORM 2234 APR 97 Device types 01 and 02 Case outlines X and Y Terminal number Terminal symbol 1 2 3 4 5 6 7 8 GND GND SHUTDOWN NO CONNECT VOUTVOUTVINVINFIGURE 2. Terminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICRO

48、CIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 9 DSCC FORM 2234 APR 97 Device types 01 and 02. FIGURE 3. Radiation exposure circuits. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-09209 DLA LAND AND MARITIME COLUMBUS

展开阅读全文
相关资源
猜你喜欢
  • BS EN 16831-2016 Tractors and machinery for agriculture and forestry Safety Format for reporting accidents《农林业用拖拉机和机械 安全性 事故报告格式》.pdf BS EN 16831-2016 Tractors and machinery for agriculture and forestry Safety Format for reporting accidents《农林业用拖拉机和机械 安全性 事故报告格式》.pdf
  • BS EN 16836-1-2016 Communication systems for meters Wireless mesh networking for meter data exchange Introduction and standardization framework《仪表通信系统 仪表数据交换用无线网状网络 介绍和标准框架》.pdf BS EN 16836-1-2016 Communication systems for meters Wireless mesh networking for meter data exchange Introduction and standardization framework《仪表通信系统 仪表数据交换用无线网状网络 介绍和标准框架》.pdf
  • BS EN 16836-2-2016 Communication systems for meters Wireless mesh networking for meter data exchange Networking layer and stack specification《仪表通信系统 仪表数据交换用无线网状网络 网络层和栈规格》.pdf BS EN 16836-2-2016 Communication systems for meters Wireless mesh networking for meter data exchange Networking layer and stack specification《仪表通信系统 仪表数据交换用无线网状网络 网络层和栈规格》.pdf
  • BS EN 16836-3-2016 Communication systems for meters Wireless mesh networking for meter data exchange Energy profile specification dedicated application layer《仪表通信系统 仪表数据交换用无线网状网络 能.pdf BS EN 16836-3-2016 Communication systems for meters Wireless mesh networking for meter data exchange Energy profile specification dedicated application layer《仪表通信系统 仪表数据交换用无线网状网络 能.pdf
  • BS EN 16838-2016 Refrigerated display scooping cabinets for gelato Classification requirements and test conditions《冰淇淋冷藏挖取陈列柜 分类 要求和试验条件》.pdf BS EN 16838-2016 Refrigerated display scooping cabinets for gelato Classification requirements and test conditions《冰淇淋冷藏挖取陈列柜 分类 要求和试验条件》.pdf
  • BS EN 16841-1-2016 Ambient air Determination of odour in ambient air by using field inspection Grid method《环境空气 利用现场检验测定环境空气中的气味 网格法》.pdf BS EN 16841-1-2016 Ambient air Determination of odour in ambient air by using field inspection Grid method《环境空气 利用现场检验测定环境空气中的气味 网格法》.pdf
  • BS EN 16841-2-2016 Ambient air Determination of odour in ambient air by using field inspection Plume method《环境空气 利用现场检验测定环境空气中的气味 羽流法》.pdf BS EN 16841-2-2016 Ambient air Determination of odour in ambient air by using field inspection Plume method《环境空气 利用现场检验测定环境空气中的气味 羽流法》.pdf
  • BS EN 16844-2017 Aesthetic medicine services Non-surgical medical treatments《美容医学服务 非手术医疗》.pdf BS EN 16844-2017 Aesthetic medicine services Non-surgical medical treatments《美容医学服务 非手术医疗》.pdf
  • BS EN 16845-1-2017 Photocatalysis Anti-soiling chemical activity using adsorbed organics under solid solid conditions Dyes on porous surfaces《光催化 固体 固体条件下使用吸附有机物的防污化学活性 多孔表面染料》.pdf BS EN 16845-1-2017 Photocatalysis Anti-soiling chemical activity using adsorbed organics under solid solid conditions Dyes on porous surfaces《光催化 固体 固体条件下使用吸附有机物的防污化学活性 多孔表面染料》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1