1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Update to reflect latest changes in format and requirements. Editorial changes throughout. -les 01-06-27 Raymond Monnin B Update drawing to current requirements. Editorial changes throughout. - gap 08-11-10 Robert M. Heber The original first shee
2、t of this drawing has been replaced. REV SHET REV SHET REV STATUS REV B B B B B B B B B OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 PMIC N/A PREPARED BY Larry T. Gauder DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY Tim A. Noh COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAW
3、ING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY William K. Heckman MICROCIRCUIT, DIGITAL, BIPOLAR, ADVANCED SCHOTTKY TTL, OCTAL BUFFER AND LINE AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 90-01-16 DRIVER WITH OPEN-COLLECTOR OUTPUTS, MONOLITHIC SILICON AMSC N/A REVISION LE
4、VEL B SIZE A CAGE CODE 67268 5962-87767 SHEET 1 OF 9 DSCC FORM 2233 APR 97 5962-E264-08 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION
5、LEVEL B SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A. 1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following exampl
6、e: 5962-87767 01 R X Drawing number Device type (see 1.2.1) Case outline(see 1.2.2) Lead finish(see 1.2.3)1.2.1 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 54AS760 Octal buffer and line driver with open-collector outputs
7、 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style R GDIP1-T20 or CDIP2-T20 20 Dual-in-line S GDFP2-F20 or CDFP3-F20 20 Flat package 2 CQCC1-N20 20 Square leadless chip carrier 1.2.3 Lead finish.
8、 The lead finish is as specified in MIL-PRF-38535, appendix A. 1.3 Absolute maximum ratings. Supply voltage range . -0.5 V dc minimum to +7.0 V dc maximum Input voltage range (VIN) . -1.2 V dc at -18 mA to +7.0 V dc Storage temperature range . -65C to +150C Maximum power dissipation (PD) . 517 mW Le
9、ad temperature (soldering, 10 seconds) +300C Thermal resistance, junction-to-case (JC) See MIL-STD-1835 Junction temperature (TJ) +175C 1.4 Recommended operating conditions. Supply voltage range (VCC) . +4.5 V dc minimum to +5.5 V dc maximum Minimum high level input voltage (VIH) 2.0 V dc Maximum lo
10、w level input voltage (VIL) . 0.8 V dc High level output voltage (VOH) . 5.5 V dc Case operating temperature range (TC) -55C to +125C Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY CENTE
11、R COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise speci
12、fied, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Int
13、erface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardizat
14、ion Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes appli
15、cable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified herein. Product built to this drawing that is pro
16、duced by a Qualified Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying activity approval in accor
17、dance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device. These modifications shall not affect the PIN as described herein. A “Q“ or “QML“ cer
18、tification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535, appendix A and herein. 3.2.1 Case outlines. The case
19、 outlines shall be in accordance with 1.2.2 herein. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1. 3.2.3 Truth table. The truth table shall be as specified on figure 2. 3.2.4 Test circuit and switching waveforms. The test circuit and switching waveforms shall
20、 be as specified on figure 3. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full case operating temperature range. 3.4 Electrical test requirements. The electrical test re
21、quirements shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY CENTER COLUMBUS C
22、OLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 4 DSCC FORM 2234 APR 97 3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. For packages where marking of the ent
23、ire SMD PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the “5962-“ on the device. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance to MIL-PRF-38535, appendix A. The complian
24、ce indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used. 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of sup
25、ply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to listing as an approved source of supply shall affirm that the manufacturers product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance. A cer
26、tificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing. 3.8 Notification of change. Notification of change to DSCC-VA shall be required for any change that affects this drawing. 3.9 Verification and review. DSCC, DS
27、CCs agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the reviewer. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures sh
28、all be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-
29、883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as
30、 applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TA= +125C, minimum. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manuf
31、acturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance character
32、istics. Test Symbol Conditions -55C TC+125C 1/ Group A subgroups Limits Unit unless otherwise specified Min Max Low level output voltage VOLVCC= 4.5 V, VIL= 0.8 V, IOL=-48 mA 2/ 1, 2, 3 0.55 V Input clamp voltage VICVCC= 4.5 V, IN= -18 mA 1, 2, 3 -1.2 V Low level input current IILG inputs 1, 2, 3 -0
33、.5 mA VCC= 5.5 V, VIN= 0.4 V A inputs 1, 2, 3 -1.0 mA High level input current IIHVCC= 5.5 V, VIN= 2.7 V 1, 2, 3 20 A Supply current ICCH VCC= 5.5 V 1, 2, 3 32 mA ICCL VCC= 5.5 V 1, 2, 3 94 mA Functional tests See 4.3.1c 3/ 7, 8 tPLH1 9, 10, 11 3 19.5 ns Propagation delay time, input An to output Yn
34、 tPHL1 9, 10, 11 1 7 tPLH2 9, 10, 11 3 19.5 ns Propagation delay time, input G to output Yn tPHL2 VCC= 4.5 V to 5.5 V, CL= 50 pF 4/ RL= 500 9, 10, 11 1 8 1/ Unused inputs that do not directly control the pin under test must be 2.5 V or 0.4 V, but shall not exceed 5.5 V or go less than 0.0 V and no i
35、nputs shall be floating. 2/ All outputs must be tested. In the case where only one input at VILmaximum or VIHminimum produces the proper output state, the test must be performed with each input being selected as the VILmaximum or VIHminimum input. 3/ Functional test shall be conducted at input test
36、conditions of GND VIL VOLand VOH VIH VCC. 4/ Propagation delay limits are based on single output switching. Unused outputs = 3.5 V or 0.3 V. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPL
37、Y CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 6 DSCC FORM 2234 APR 97 Device type 01 Case outlines R, S, and 2 Terminal number Terminal Symbol 1 1 G 2 1A1 3 2Y4 4 1A2 5 2Y3 6 1A3 7 2Y2 8 1A4 9 2Y1 10 GND 11 2A1 12 1Y4 13 2A2 14 1Y3 15 2A3 16 1Y2 17 2A4 18 1Y1 19 2 G 20 VCCFIGURE
38、 1. Terminal connections. Inputs Output An G Yn X H Disabled L L L H L H H = High level.L Low level. X = Irrelevant. FIGURE 2. Truth table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY
39、 CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 7 DSCC FORM 2234 APR 97 NOTES: 1. CLincludes probe and jig capacitance. 2. All input pulses have the following characteristics: PRR 10 MHz, duty cycle = 50%, tr= tf= 3ns 1 ns. 3. The outputs are measured one at a time with one input t
40、ransition per measurement. FIGURE 3. Test circuit and switching waveforms. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET
41、 8 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-STD-883 test requirements Subgroups (in accordance with MIL-STD-883, method 5005, table I) Interim electrical parameters (method 5004) - - - Final electrical test parameters (method 5004) 1*, 2, 3, 7, 8, 9, 10, 11 Group A test requ
42、irements (method 5005) 1, 2, 3, 7, 8, 9, 10, 11 Groups C and D end-point electrical parameters (method 5005) 1, 2, 3 * PDA applies to subgroup 1. 4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-883 including groups A, B, C, and D
43、inspections. The following additional criteria shall apply. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 4, 5, and 6 in table I, method 5005 of MIL-STD-883 shall be omitted. c. Subgroups 7 and 8 shall include verification of the truth table. 4.3.2 Groups
44、C and D inspections. a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and sha
45、ll be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA= +125C, minimum. (3) Test duration: 1,000 hours, e
46、xcept as permitted by method 1005 of MIL-STD-883. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-87767 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 9 DSCC FORM 2234 APR 97
47、5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications,
48、and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3 Configuration control of SMDs. All proposed changes to existing SMDs will be coordinated with the users of record for the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal. 6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC)