1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R266-92. 92-09-18 M. A. FRYE B Changed title block to reflect correct nomenclature. Updated boiler plate to meet current requirements. -lgt 01-07-20 R. MONNIN C Update drawing as part of 5 year review. -rrp 06-
2、04-25 R. MONNIN D Update drawing to reflect latest changes in format and requirements. -rrp 13-01-16 C. SAFFLE THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED. REV SHEET REV SHEET REV STATUS REV D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A PREPARED BY JOSEPH A. K
3、ERBY DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY CHARLES E. BESORE APPROVED BY MICHAEL A. FRYE MICROCIRCUIT, LINEAR, POSITIVE
4、REGULATOR, FIXED 24 VOLT, MONOLITHIC SILICON DRAWING APPROVAL DATE 90-05-24 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-88554 SHEET 1 OF 11 DSCC FORM 2233 APR 97 5962-E198-13 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIR
5、CUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A. 1.
6、2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example: 5962-88554 01 X A Drawing number Device type (see 1.2.1) Case outline (see 1.2.2) Lead finish (see 1.2.3) 1.2.1 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic
7、number Circuit function 01 7824A 1.0 A positive regulator, fixed 24-volt 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 3 Can (Similar to TO-39) Y See figure 1 2 Can (Similar to
8、 TO-3) Z See figure 1 2 Can (Similar to TO-66) 1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A. 1.3 Absolute maximum ratings. Supply voltage range Operating or output shorted to ground 40 V dc Transient . 50 V dc 1/ Storage temperature range -65C to +150C Lead tempera
9、ture (soldering, 10 seconds) . +300C Power dissipation (PD): TC= +25C: Case X . 2 W Case Y . 20 W Case Z . 15 W TA= +25C: Case X . 1 W Case Y . 4.3 W Case Z . 15 W Thermal resistance, junction-to-case (JC): Case X . 15C/W Case Y . 3C/W Case Z . 6C/W 1/ The 50-volt input rating refers to the ability
10、of the regulator to withstand high line or transient condition without damage. Since the regulators maximum current capability is reduced, the output may fall out of regulation at high input voltage under nominal loading. Provided by IHSNot for ResaleNo reproduction or networking permitted without l
11、icense from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.3 Absolute maximum ratings - Continued. Thermal resistance, junction-to-ambient (JA): Case X 120C/W Case Y 35C/W Case Z 50C/W Junction-
12、to-ambient (TJ) . +150 2/ 1.4 Recommended operating conditions. Ambient operating temperature range (TA) -55C to +125C Input voltage range 28 V dc to 38 V dc 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a p
13、art of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STAN
14、DARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available
15、 online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing
16、 takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devi
17、ces and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-PRF-38535 may be processed as QML product in accordance with the manufac
18、turers approved program plan and qualifying activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device. These modifica
19、tions shall not affect the PIN as described herein. A “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
20、in MIL-PRF-38535, appendix A and herein. 3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 2/ The device is protected by a thermal shutdown circuit which is designed to t
21、urn off the output transistor whenever the device junction temperature is in excess of 150C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVE
22、L D SHEET 4 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ -55C TA +125C unless otherwise specified Group A subgroups Device type Limits Unit Min Max Output voltage VOUT TA= +25C 1 01 23.6 24.4 V VIN = 28 V to 38 V 2/ 2, 3 23.3 24.7 Line regulation 3
23、/ 4/ VRLINEVIN= 27 V to 38 V 1 01 120 mV 2, 3 240 VIN = 30 V to 36 V 1 60 2, 3 120 Load regulation 3/ VRLOAD IO = 5.0 mA to 1.5 A 5/ 1 01 160 mV 2, 3 320 IO = 250 mA to 750 mA 5/ 1 80 2, 3 160 IO = 5 mA to 500 mA 6/ 1 80 2, 3 160 Standby current drain ISCD 1 01 6.0 mA 2, 3 7.0 Standby current drain
24、change with line ISCD(LINE)VIN = 28 V to 38 V 1, 2, 3 01 0.8 mA Standby current drain change with load ISCD(Load)IO = 5.0 mA to 1000 mA 1, 2, 3 01 0.5 mA Dropout voltage VDO VOUT= 100 mV IO= 1.0 A 5/ 1, 2, 3 01 2.5 V IO = 500 mA 6/ 2.5 Peak output current IO(PK) TA = +25C 5/ 1 01 1.5 3.3 A 6/ 0.5 1.
25、7 Short circuit current 7/ IOSVIN= 35 V 5/ 1 01 1.2 A 2, 3 2.8 6/ 1 0.7 2, 3 2.0 See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218
26、-3990 REVISION LEVEL D SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions 1/ -55C TA +125C unless otherwise specified Group A subgroups Device type Limits Unit Min Max Ripple rejection OUTINVVTA= +25C, f = 120 Hz, VIN= 10 V 4 01 56 dB Ou
27、tput noise voltage 8/ NOTA= +25C, f = 10 Hz to 100 kHz 7 01 40 VVrms Long term stability 8/ tVOUTTA= +25C, T = 1000 hours 7 01 151 mV 1/ Unless otherwise specified, VIN= 33 V and IO= 500 mA for cases Y and Z, VIN= 33 V and IO= 100 mA for case X. Maximum test current for case X is 500 mA. 2/ For case
28、 X: IO= 5 mA to 500 mA, P 2 W. For case Y: IO= 5 mA to 1.0 A, P 20 W. For case Y: IO= 5 mA to 1.0 A, P 15 W. 3/ Measurements are made at constant junction temperature and with low duty cycle. 4/ Minimum load current for full line regulation is 5.0 mA. 5/ For cases Y and Z only. 6/ For case X only. 7
29、/ Short circuit protection is only assured up to VIN= 35 V. 8/ Guaranteed if not tested. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full ambient operating temperature r
30、ange. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table I. 3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN li
31、sted in 1.2 herein. In addition, the manufacturers PIN may also be marked. In addition, the manufacturers PIN may also be marked. For packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the “5962-“ on the device
32、. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML f
33、low option is used. 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an app
34、roved source of supply shall affirm that the manufacturers product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits d
35、elivered to this drawing. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 6 DSCC FORM 2234 APR 97 Case outline X Symbol Inches Mill
36、imeters Min Max Min Max A .165 .185 4.19 4.70 A1- .100 - 2.54 b .016 .019 0.41 0.48 b1.016 .021 0.41 0.53 D .335 .370 8.51 9.40 D1.305 .335 7.75 8.51 e .200 BSC 5.08 BSC e1.100 BSC 2.54 BSC F - .050 - 1.27 k .028 .034 0.71 0.86 k1.029 .045 0.74 1.14 k2.009 .041 0.23 1.04 L .500 - 12.70 - L1- .050 -
37、1.27 L2.250 - 6.35 - 45 45 NOTE: The U.S. government preferred system of measurement is the metric SI system. However, since this item was originally designed using inch-pound units of measurement, in the event of conflict between the metric and inch-pound units, the inch-pound units shall take prec
38、edence. FIGURE 1. Case outlines. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 7 DSCC FORM 2234 APR 97 Case outline Y Symbol Inch
39、es Millimeters Min Max Min Max A .250 .450 6.35 11.35 A11.177 1.197 29.90 30.40 b .038 .043 0.97 1.09 D - .875 - 22.22 e .655 .675 16.64 17.74 e1.420 .440 10.67 11.16 e2.205 .225 5.21 5.72 F .060 .135 1.52 3.43 H .131 .188 3.84 4.09 L .312 .500 7.92 12.70 L1- .050 - 1.27 R .495 .525 12.57 13.34 R1.1
40、51 .161 3.33 4.78 NOTE: The U.S. government preferred system of measurement is the metric SI system. However, since this item was originally designed using inch-pound units of measurement, in the event of conflict between the metric and inch-pound units, the inch-pound units shall take precedence. F
41、IGURE 1. Case outline Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 8 DSCC FORM 2234 APR 97 Case outline Z Symbol Inch
42、es Millimeters Min Max Min Max A .250 .340 6.35 8.64 A1.958 .962 24.33 24.43 b .028 .034 0.97 1.09 D - .620 - 15.75 e .570 .590 14.48 14.99 e1.190 .210 4.83 5.33 e2.093 .107 2.36 2.72 F .050 .075 1.27 1.91 H .142 .152 3.61 3.86 L .360 - 9.14 - R - .350 - 8.89 R1.145 - 3.68 NOTE: The U.S. government
43、preferred system of measurement is the metric SI system. However, since this item was originally designed using inch-pound units of measurement, in the event of conflict between the metric and inch-pound units, the inch-pound units shall take precedence. FIGURE 1. Case outline Continued. Provided by
44、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 9 DSCC FORM 2234 APR 97 NOTE: 1. These are the “bottom view” of the can packages. FIGURE 2. Te
45、rminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-88554 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 10 DSCC FORM 2234 APR 97 3.8 Notification of change. Notificati
46、on of change to DLA Land and Maritime -VA shall be required for any change that affects this drawing. 3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritimes agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentat
47、ion. Offshore documentation shall be made available onshore at the option of the reviewer. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. Screening shall be in accordance with method 5004 of MIL-ST
48、D-883, and shall be conducted on all devices prior to quality conformance inspection. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition C or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to