DLA SMD-5962-94536 REV D-2012 MICROCIRCUIT HYBRID LINEAR 11 8-VOLT SYNCHRO AND RESOLVER TO DIGITAL CONVERTER.pdf

上传人:Iclinic170 文档编号:700447 上传时间:2019-01-01 格式:PDF 页数:14 大小:171.33KB
下载 相关 举报
DLA SMD-5962-94536 REV D-2012 MICROCIRCUIT HYBRID LINEAR 11 8-VOLT SYNCHRO AND RESOLVER TO DIGITAL CONVERTER.pdf_第1页
第1页 / 共14页
DLA SMD-5962-94536 REV D-2012 MICROCIRCUIT HYBRID LINEAR 11 8-VOLT SYNCHRO AND RESOLVER TO DIGITAL CONVERTER.pdf_第2页
第2页 / 共14页
DLA SMD-5962-94536 REV D-2012 MICROCIRCUIT HYBRID LINEAR 11 8-VOLT SYNCHRO AND RESOLVER TO DIGITAL CONVERTER.pdf_第3页
第3页 / 共14页
DLA SMD-5962-94536 REV D-2012 MICROCIRCUIT HYBRID LINEAR 11 8-VOLT SYNCHRO AND RESOLVER TO DIGITAL CONVERTER.pdf_第4页
第4页 / 共14页
DLA SMD-5962-94536 REV D-2012 MICROCIRCUIT HYBRID LINEAR 11 8-VOLT SYNCHRO AND RESOLVER TO DIGITAL CONVERTER.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Add case outline Y. Update document to MIL-PRF-38534 requirements. 97-07-14 K. A. Cottongim B Figure 2, terminal connections, correct terminal symbol for pins 8, 28, 29, 30, 31, 48, and 54, for all device types. Table II, correct subgroups for in

2、terim electrical parameters. Update drawing boilerplate. 02-07-10 Raymond Monnin C Rewrite paragraphs 4.2.a.2. and 4.3.3.b.2 to add TC. 04-07-16 Raymond Monnin D Update drawing paragraphs. -sld 12-07-12 Greg Cecil REV SHEET REV SHEET REV STATUS REV D D D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5

3、 6 7 8 9 10 11 12 13 PMIC N/A PREPARED BY Gary Zahn DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE APPROVED BY

4、Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 11.8-VOLT, SYNCHRO AND RESOLVER TO DIGITAL CONVERTER DRAWING APPROVAL DATE 94-07-06 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-94536 SHEET 1 OF 13 DSCC FORM 2233 APR 97 5962-E266-12 Provided by IHSNot for ResaleNo reproduction or networki

5、ng permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94536 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF

6、-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 94536 01 H

7、X A Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified

8、 RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function Frequency Accuracy 1 LSB 01 SD-14620DX-112, SD-14620FX-112 11.8 V

9、 S/D converter 400 Hz 4 min 02 SD-14621DX-112, SD-14621FX-112 11.8 V R/D converter 400 Hz 4 min 03 SD-14620DX-114, SD-14620FX-114 11.8 V S/D converter 400 Hz 2 min 04 SD-14621DX-114, SD-14621FX-114 11.8 V R/D converter 400 Hz 2 min 05 SDC-14621-601 6.8 V R/D converter 400 Hz 2 min 1.2.3 Device class

10、 designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance lev

11、els are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required

12、. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspection

13、s (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensur

14、e that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networkin

15、g permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94536 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descript

16、ive designator Terminals Package style X See figure 1 54 Dual-in-line Y See figure 1 54 Flat pack 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Positive supply voltage (VCC) . +7.0 V dc Reference input voltage . 35 V rms Digital input vol

17、tage range . -0.3 V dc to +7.0 V dc Power dissipation, TA= +125 C (PD) . 350 mW Storage temperature range -65 C to +150 C Lead temperature (soldering, 10 seconds) +300 C Thermal resistance junction-to-case (qJC) 8.0 C/W Thermal resistance junction-to-ambient (qJA) . 20 C/W 1.4 Recommended operating

18、conditions. Positive supply voltage (VCC) . +4.75 V dc to +5.25 V dc Reference input voltage range . 2.0 V rms to 35 V rms Reference input carrier frequency range 360 Hz to 5000 Hz Signal input voltage range . 10.62 V rms to 12.98 V rms Ambient operating temperature range (TA) -55 C to +125 C 2. APP

19、LICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPAR

20、TMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - L

21、ist of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence

22、. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximu

23、m ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94536 DLA LAND AND

24、MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the perfor

25、mance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534

26、shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as speci

27、fied in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.2.3 Block diagram. The block diagram shall be as specified on figure 3. 3.3 El

28、ectrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgrou

29、ps specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also

30、be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein

31、. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made available to the preparing activity (DLA Land and Maritime -VA) upon request.

32、3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime -VA shall affirm that the manufacturers product meets the performance requirements of

33、MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with

34、MIL-PRF-38534 or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. 4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply: a

35、. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to either DLA Land and Maritime -VA or the acquiring activity upon request. Also, the test circuit

36、shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TAor TCas specified in the approved manufacturers QM plan. b. Interim and final electrical test parameters shall be as specified in table II her

37、ein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94536 DLA LAND AND MARITIME COLUMBUS, OHIO 4

38、3218-3990 REVISION LEVEL D SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions -55 C TA +125 C VCC= +5 V dc, unless otherwise specified Group A subgroups Device type Limits Unit Min Max Resolution control 1/ RC A = B = 0.8 V 7,8A,8B All 10 10 Bits A

39、= 2.0 V, B = 0.8 V 12 12 A = 0.8 V, B = 2.0 V 14 14 A = B = 2.0 V 16 16 Accuracy repeatability AR 2/ 3/ 7,8A,8B All -1.0 +1.0 LSB Accuracy differential AD 2/ 3/ 7,8A,8B All -1.0 +1.0 LSB Output accuracy AOUT 2/ 7,8A,8B 01,02 -13 +13 LSB 03,04,05 -7 +7 Reference input voltage range 3/ VIN14,5,6 All 2

40、.0 35 V rms Reference input impedance 3/ ZIN1Single ended 4,5,6 All 60 kW Differential 120 Reference input common mode range 3/ VCM14,5,6 All -50 +50 V pk Signal input common mode range 3/ VCM24,5,6 All -30 +30 V pk Signal input impedance 3/ ZIN2 Line-to-line 4,5,6 01,03 52 kW Line-to-ground 34 Sing

41、le ended 02,04,05 70 Differential 140 Digital output low voltage VOLIOL= -1.6 mA 1,2,3 All 0.4 V Digital output high voltage VOHIOH= 0.4 mA 1,2,3 All 2.8 V Output leakage current IOZ1,2,3 All -40 +40 mA See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitt

42、ed without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94536 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 6 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions -55 C TA +125 C VCC= +5 V dc, unless othe

43、rwise specified Group A subgroups Device type Limits Unit Min Max Digital input high voltage 1/ VIHDigital inputs A, B, INH, EL, and EM. VIN= 2.0 V 1,2,3 All pass/ fail Digital input low voltage 1/ VILDigital inputs A, B, INH, EL, and EM. VIN= 0.8 V 1,2,3 All pass/ fail Digital input current 1/ IINI

44、nternal pull-up 4,5,6 All 10 mA Inhibit voltage 1/ VINHNo digital angles change while INH is logic 0 and analog input is rotating 7,8A,8B All 0.8 V Enable voltage 1/ VEEM controls output bits 1 through 8 and EL controls output bits 9 through 16. 7,8A,8B All 0.8 V Disable voltage 1/ (high impedance)

45、VDEM controls output bits 1 through 8 and EL controls output bits 9 through 16. 7,8A,8B All 2.0 V Positive supply voltage ICCVCC= +5.25 V, each channel 1,2,3 All +68 mA Analog velocity output voltage VOUT4/ 7,8A,8B All 3.24 4.00 V Bandwidth 1/ BW 7,8A,8B All 39 72 Hz 1/ These parameters are tested o

46、n a go-no-go basis only or in conjunction with other measured parameters and are not directly testable. 2/ Output accuracy is measured at angles from 0 to 180 , in 15 increments, and at 225 , 270 , and 315 . 3/ Parameters shall be tested as part of device initial characterization and after design an

47、d process changes. Parameter shall be guaranteed to the limits specified in table I for all lots not specifically tested. 4/ Analog output voltage is tested at 2 revolutions per second. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCI

48、RCUIT DRAWING SIZE A 5962-94536 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 7 DSCC FORM 2234 APR 97 Case outline X. Symbol Millimeters Inches Minimum Maximum Minimum Maximum A1 5.33 .210 b 0.41 0.51 .016 .020 b1 1.14 1.40 .045 .055 D 38.10 1.500 D1 32.89 33.15 1.295 1.305 D2 30.35 30.61 1.195 1.205 D3 2.41 2.67 .095 .105 D4 1.14 1.40 .045 .055 E 19.81 .780 E1 15.11 15.37 .595

展开阅读全文
相关资源
猜你喜欢
  • BS EN 81-28-2003 Safety rules for the construction and installation of lifts - Remote alarm on passenger and goods passenger lifts《电梯的建造和安装的安全规则 客用梯和货用梯上的遥控警报器》.pdf BS EN 81-28-2003 Safety rules for the construction and installation of lifts - Remote alarm on passenger and goods passenger lifts《电梯的建造和安装的安全规则 客用梯和货用梯上的遥控警报器》.pdf
  • BS EN 81-31-2010 Safety rules for the construction and installation of lifts - Lifts for the transport of goods only - Accessible goods only lifts《电梯的建造和安装用安全性规程 仅供货物运输的电梯 仅用于货物进入的.pdf BS EN 81-31-2010 Safety rules for the construction and installation of lifts - Lifts for the transport of goods only - Accessible goods only lifts《电梯的建造和安装用安全性规程 仅供货物运输的电梯 仅用于货物进入的.pdf
  • BS EN 81-41-2010 Safety rules for the construction and installation of lifts Special lifts for the transport of persons and goods Vertical lifting platforms intended for use by per.pdf BS EN 81-41-2010 Safety rules for the construction and installation of lifts Special lifts for the transport of persons and goods Vertical lifting platforms intended for use by per.pdf
  • BS EN 81-43-2009 Safety rules for the construction and installation of lifts - Special lifts for the transport of persons and goods - Part 43 Lifts for cranes《电梯建造和安装的安全规则 载人和载物专用电.pdf BS EN 81-43-2009 Safety rules for the construction and installation of lifts - Special lifts for the transport of persons and goods - Part 43 Lifts for cranes《电梯建造和安装的安全规则 载人和载物专用电.pdf
  • BS EN 81-50-2014 Safety rules for the construction and installation of lifts Examinations and tests Design rules calculations examinations and tests of lift components《电梯制造和安装用安全规则.pdf BS EN 81-50-2014 Safety rules for the construction and installation of lifts Examinations and tests Design rules calculations examinations and tests of lift components《电梯制造和安装用安全规则.pdf
  • BS EN 81-58-2003 Safety rules for the construction and installation of lifts - Examination and tests - Landing doors fire resistance test《升降机建造和安装的安全规则 检验和试验 电梯入门防火试验》.pdf BS EN 81-58-2003 Safety rules for the construction and installation of lifts - Examination and tests - Landing doors fire resistance test《升降机建造和安装的安全规则 检验和试验 电梯入门防火试验》.pdf
  • BS EN 81-70-2003 Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Accessibility to lifts for persons .pdf BS EN 81-70-2003 Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Accessibility to lifts for persons .pdf
  • BS EN 81-71-2005 Safety rules for the construction and installation of lifts - Particular applications to passenger lifts and goods passenger lifts - Vandal resistant lifts《电梯建造和安装.pdf BS EN 81-71-2005 Safety rules for the construction and installation of lifts - Particular applications to passenger lifts and goods passenger lifts - Vandal resistant lifts《电梯建造和安装.pdf
  • BS EN 81-72-2015 Safety rules for the construction and installation of lifts Particular applications for passenger and goods passenger lifts Firefighters lifts《升降机建造和安装的安全规程 载人和载货升.pdf BS EN 81-72-2015 Safety rules for the construction and installation of lifts Particular applications for passenger and goods passenger lifts Firefighters lifts《升降机建造和安装的安全规程 载人和载货升.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1