1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table I, supply current test, subgroups column, add 1, 2, and 3. Update drawing to current requirements. 05-04-01 Raymond Monnin B Updated drawing paragraphs to MIL-PRF-38534 requirements. -sld 13-12-10 Charles F. Saffle REV SHEET REV SHEET REV S

2、TATUS REV B B B B B B B B B B OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 PMIC N/A PREPARED BY Gary Zahn DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED

3、 BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, DIGITAL, REMOTE TERMINAL AND BUS CONTROLLER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 94-11-08 AMSC N/A REVISION LEVEL B SIZE A CAGE CODE 67268 5962-94775 SHEET 1 OF 10 DSCC FORM 2233 APR 97 5962-E076-14 Provided by IHSNot for Resa

4、leNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined i

5、n paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the followin

6、g example: 5962 - 94775 01 H X A Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall mee

7、t the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 CT1990 Remote terminal and bus co

8、ntroller 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D)

9、. The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high relia

10、bility devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic

11、 and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document

12、should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. 1.2.4 Case outline(s). The cas

13、e outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 90 Dual-in-line Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-9477

14、5 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 3 DSCC FORM 2234 APR 97 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Supply voltage (VCC) -0.3 V dc to +7.0 V dc Input or output voltage at any pad . -0.3 V dc to V

15、CC + 0.3 V dc Thermal resistance junction-to-case (JC) . 2C/W 1.4 Recommended operating conditions. Supply voltage range (VCC) . +5.0 V dc 10% Case operating temperature range (TC) -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specificati

16、on, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEP

17、ARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of th

18、ese documents are available online at http:/quicksearch.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the t

19、ext of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in acco

20、rdance with MIL-PRF-38534. Compliance with MIL-PRF-38534 shall include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and insp

21、ections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physica

22、l dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.

23、 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DR

24、AWING SIZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 4 DSCC FORM 2234 APR 97 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full s

25、pecified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-385

26、34. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test d

27、ata (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision

28、 level control by the manufacturer and be made available to the preparing activity (DLA Land and Maritime -VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original co

29、py) submitted to DLA Land and Maritime -VA shall affirm that the manufacturers product meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered

30、to this drawing. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38534 or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described

31、 herein. 4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control an

32、d shall be made available to either DLA Land and Maritime -VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TA as specified in

33、accordance with table I of method 1015 of MIL-STD-883. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. Provided by IHSNot for ResaleNo reproduction

34、 or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions -55C TA +125C unless otherwise

35、specified Group A subgroups Device type Limits Unit Min Max Supply voltage VCC 1,2,3 01 4.5 5.5 V High level input voltage VIH VCC = 5.0 V 1,2,3 01 2.2 V Low level input voltage VIL VCC = 5.0 V 1,2,3 01 0.7 V High level output voltage VOH VCC = 4.5 V 1/ 1,2,3 01 2.4 V Low level output voltage VOL VC

36、C = 4.5 V 1/ 1,2,3 01 0.4 V High level input current IIH VCC = 5.5 V, VIN = 2.4 V 2/ 1,2,3 01 -200 -700 A 3/ 1,2,3 01 -25 -400 Low level input current IIL VCC = 5.5 V, VIN = 0.4 V 2/ 1,2,3 01 -400 -900 A 3/ 1,2,3 01 -25 -400 Supply current ICC VCC = 5.5 V 4/ 1,2,3 01 20 mA 1/ IOL = 3 mA maximum, IOH

37、 = -2 mA maximum for TX INHIBIT 0, 1, and TX DATA / DATA, only. IOL = 2 mA maximum, IOH = -1 mA maximum for all remaining outputs and bidirectionals. 2/ RTAD 0, 1, 2, 3, 4, and RTADPAR only. 3/ All inputs and bidirectionals other than those in note 2. 4/ All inputs are open. All outputs and bidirect

38、ionals have no load. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 6 DSCC FORM 2234 APR 97 Case outline X. FIGURE 1. Case outline

39、. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 7 DSCC FORM 2234 APR 97 Case outline X - Continued. Symbol Millimeters Inches Min

40、 Max Min Max A 5.72 .225 b 0.41 0.51 .016 .020 D 60.96 2.400 D1 55.75 56.01 2.195 2.205 D2 53.21 53.46 2.095 2.105 D3 2.41 2.67 .095 .105 D4 1.14 1.40 .045 .055 E 40.64 1.600 E1 32.89 33.15 1.295 1.305 E2 27.81 28.07 1.095 1.105 E3 2.41 2.67 .095 .105 L 4.45 .175 NOTES: 1. The U.S. preferred system

41、of measurement is the metric SI. This item was designed using inch-pound units of measurement. In case of problems involving conflicts between the metric and inch-pound units, the inch-pound units shall rule. 2. Pin numbers are for reference only. FIGURE 1. Case outline - Continued. Provided by IHSN

42、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 8 DSCC FORM 2234 APR 97 Device type 01 Device type 01 Case outline X Case outline X Terminal number

43、 Terminal symbol Terminal number Terminal symbol 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 BIT DECODE CWCO (LSB) SA4 (MSB) SA3 SA2 CWC4 (MSB) CWC3 CWC2 CWC1 GBR H / L STATEN / STATSTB EOT SA1 SA0 (LSB) INCMD TX/RX DT

44、RQ VECTEN / DWEN NBGT SYNC INCLK IUSTB NEXT STAT DTAK BCOPA BCOPSTB BCOPB PASMON NDRQ REQBUSB REQBUSA COMMON AND CASE ENABLE STAT UPDATE MEREQ IH08 (LSB) IH19 IH210 IH311 IH412 IH513 IH614 IH715 (MSB) No connect (internal) 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71

45、 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 No connect (internal) RTADPAR RTAD0 (LSB) RTAD1 RTAD2 RTAD3 RTAD4 (MSB) CMSYNC DWSYNC BCSTEN 0 RX DATA 0 RX DATA 0 BCSTEN 1 RTO 6 MCK ERROR LTFAIL MANER PARER VALD READER RX DATA 1 RX DATA 1 +5 VIN TX INHIBIT 1 TX INHIBIT 0 TX DATA TX DATA SE

46、RVREQ TXTO DBCACC RESET RT / BC DBCREQ HSFAIL LSTCMD/CWEN BITEN / RMDSTB BUSY WC4 (MSB) WC3 WC0 (LSB) SSERR WC2 WC1 No connect (internal) FIGURE 2. Terminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SI

47、ZE A 5962-94775 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 9 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-PRF-38534 test requirements Subgroups (in accordance with MIL-PRF-38534, group A test table) Interim electrical parameters - Final electrical par

48、ameters 1*, 2, 3 Group A test requirements 1, 2, 3 Group C end-point electrical parameters 1, 2, 3 End-point electrical parameters for radiation hardness assurance (RHA) devices Not applicable * PDA applies to subgroup 1. 4.3 Conformance and periodic inspections. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance with MIL-PRF-38534 and as specified herein. 4.3.1 Group A inspec