DLA W-C-375 13 B-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (15 THROUGH 50 AMPERES).pdf

上传人:confusegate185 文档编号:701433 上传时间:2019-01-01 格式:PDF 页数:3 大小:41.11KB
下载 相关 举报
DLA W-C-375 13 B-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (15 THROUGH 50 AMPERES).pdf_第1页
第1页 / 共3页
DLA W-C-375 13 B-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (15 THROUGH 50 AMPERES).pdf_第2页
第2页 / 共3页
DLA W-C-375 13 B-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (15 THROUGH 50 AMPERES).pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 W-C-375/13B 16 June 2009 SUPERSEDING W-C-375/13A 04 August 2004 FEDERAL SPECIFICATION SHEET CIRCUIT BREAKERS, MOLDED CASE, BRANCH CIRCUIT AND SERVICE, TYPE I, SERIES TRIP, SINGLE POLE (15 THROUGH 50 AMPERES) The General Services Administration has authorized the use of this federal specification sh

2、eet by all federal agencies. The complete requirements for procuring circuit breakers described herein shall consist of this document and the latest issue in effect of W-C-375. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Tolerance is .01 (0.25

3、 mm) for two-place decimals and .005 (0.13 mm) for three-place decimals. 4. Terminal lugs shall accept #14 to #4 AWG wire and shall be suitable for aluminum (AL) or copper (CU) wire. FIGURE 1. Interface and physical dimensions. AMSC N/A FSC 5925 INCH-POUND Inches mm .312 7.92 1.000 25.40 1.250 31.75

4、 1.562 39.67 2.312 58.72 2.875 73.03 3.094 78.59 3.344 84.94 W-C-375/13 is inactive for new design and is no longer used, except for replacement purposes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-375/13B 2 REQUIREMENTS: Interface and physi

5、cal dimensions: See figure 1. Trip indication: See figure 1. Electrical: Interrupting current rating: RMS symmetrical, 10,000 amperes. Voltage rating: 120/240 V ac. Trip current: See table I. Frequency: 60 hertz. Calibration: At +40C. Enclosure for overload, endurance, and short circuit tests: 15 th

6、rough 30 ampere breakers, Federal Pacific Electric Catalog No. 102-2F/S; 35 through 50 ampere breakers, Catalog No. 102-4F/S, or equivalent. TABLE I. Part or Identifying Numbers (PINs) and current rating. Government PIN Current rating WC375/13-001 15 WC375/13-002 20 WC375/13-003 25 WC375/13-004 30 W

7、C375/13-005 35 WC375/13-006 40 WC375/13-007 45 WC375/13-008 50 TABLE II. Supersession and cross reference. Government PIN Superseded number Will replace number CAGE 21810 WC375/13-001 15 NA15 15H NA15H NAH15H WC375/13-002 20 NA20 20H NA20H NAH20H WC375/13-003 25 NA25 25H NA25H NAH25H WC375/13-004 30

8、 NA30 30H NA30H NAH30H WC375/13-005 35 NA35 35H NA35H NAH35H WC375/13-006 40 NA40 40H NA40H NAH40H WC375/13-007 45 NA45 45H NA45H NAH45H WC375/13-008 50 NA50 50H NA50H NAH50H Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-375/13B 3 The margins o

9、f this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the

10、 requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITY: Custodians: GSA - FSS Navy - YD Air Force - 85 Preparing activity: DLA - CC DLA - CC Review activitie

11、s: Navy - MC, OS Project 5925-2009-005 Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS 9070 Secs 1 & 2-1969 Specification for fixed capacitors of assessed quality generic data and methods of test Principles and mandatory procedures General rules for drafting detai.pdf BS 9070 Secs 1 & 2-1969 Specification for fixed capacitors of assessed quality generic data and methods of test Principles and mandatory procedures General rules for drafting detai.pdf
  • BS 9070-3-1970 Specification for fixed capacitors of assessed quality generic data and methods of test - Tantalum electrolytic capacitors《经质量评定的固定式电容器规范 一般数据和试验方法 第3节 钽介质电容器》.pdf BS 9070-3-1970 Specification for fixed capacitors of assessed quality generic data and methods of test - Tantalum electrolytic capacitors《经质量评定的固定式电容器规范 一般数据和试验方法 第3节 钽介质电容器》.pdf
  • BS 9074 N007-1978 Detail specification for fixed polystyrene film dielectric extended foil capacitors Rectangular non-metallic case unidirectional terminations Full plus additional.pdf BS 9074 N007-1978 Detail specification for fixed polystyrene film dielectric extended foil capacitors Rectangular non-metallic case unidirectional terminations Full plus additional.pdf
  • BS 9090-1977 Variable capacitors of assessed quality generic data and methods of test《经质量评定的可变电容器 一般数据和试验方法》.pdf BS 9090-1977 Variable capacitors of assessed quality generic data and methods of test《经质量评定的可变电容器 一般数据和试验方法》.pdf
  • BS 91-1998 Electric cable soldering sockets - Specification《电缆焊接插座 规范》.pdf BS 91-1998 Electric cable soldering sockets - Specification《电缆焊接插座 规范》.pdf
  • BS 9100-1983 Specification for capability approval for custom-built capacitors and capacitor modules generic data and methods of test《定制电容器和电容器模件的性能鉴定规范 通用数据和试验方法》.pdf BS 9100-1983 Specification for capability approval for custom-built capacitors and capacitor modules generic data and methods of test《定制电容器和电容器模件的性能鉴定规范 通用数据和试验方法》.pdf
  • BS 9101-2017 Steel and aluminium rainwater systems Specification《钢和铝雨水系统 规格》.pdf BS 9101-2017 Steel and aluminium rainwater systems Specification《钢和铝雨水系统 规格》.pdf
  • BS 9102-2014 Code of practice for safe working on lifting platforms《升降平台安全作业的操作规程》.pdf BS 9102-2014 Code of practice for safe working on lifting platforms《升降平台安全作业的操作规程》.pdf
  • BS 9120-1988 Specification for radio interference suppression filters of assessed quality generic data and methods of test《经质量评定的无线电干扰抑制滤波器规格 通用数据和试验方法》.pdf BS 9120-1988 Specification for radio interference suppression filters of assessed quality generic data and methods of test《经质量评定的无线电干扰抑制滤波器规格 通用数据和试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1