DLA W-C-375 19 C-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (10 THROUGH 100 AMPERES).pdf

上传人:appealoxygen216 文档编号:701439 上传时间:2019-01-01 格式:PDF 页数:4 大小:63.18KB
下载 相关 举报
DLA W-C-375 19 C-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (10 THROUGH 100 AMPERES).pdf_第1页
第1页 / 共4页
DLA W-C-375 19 C-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (10 THROUGH 100 AMPERES).pdf_第2页
第2页 / 共4页
DLA W-C-375 19 C-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (10 THROUGH 100 AMPERES).pdf_第3页
第3页 / 共4页
DLA W-C-375 19 C-2009 CIRCUIT BREAKERS MOLDED CASE BRANCH CIRCUIT AND SERVICE TYPE I SERIES TRIP SINGLE POLE (10 THROUGH 100 AMPERES).pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 W-C-375/19C 16 June 2009 SUPERSEDING W-C-375/19B 04 August 2004 FEDERAL SPECIFICATION SHEET CIRCUIT BREAKERS, MOLDED CASE, BRANCH CIRCUIT AND SERVICE, TYPE I, SERIES TRIP, SINGLE POLE (10 THROUGH 100 AMPERES) The General Services Administration has authorized the use of this federal specification s

2、heet by all federal agencies. The complete requirements for procuring circuit breakers described herein shall consist of this document and the latest issue in effect of W-C-375. FIGURE 1. Interface and physical dimensions of single pole circuit breaker. AMSC N/A FSC 5925 INCH-POUND W-C-375/19 is ina

3、ctive for new design and is no longer used, except for replacement purposes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-375/19C 2 Inches mm Inches mm .125 3.18 1.062 26.97 .138 3.51 1.125 28.58 .164 4.17 1.375 34.93 .190 4.83 2.1 53.34 .218

4、5.54 2.25 57.15 .219 5.56 2.265 57.53 .220 5.59 2.46 62.48 .375 9.53 2.609 66.27 .684 17.37 2.750 69.85 4.750 120.65 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Tolerance is .01 (0.25 mm) for two-place decimals and .005 (0.13 mm) for three-pla

5、ce decimals. 4. OFF position is also tripped position. FIGURE 1. Interface and physical dimensions of single pole circuit breaker - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-375/19C 3 REQUIREMENTS: Interface and physical dimensio

6、ns: See figure 1. Trip indication: See figure 1. Electrical: Interrupting current rating: 5,000 amperes. Voltage rating: 120 V ac. Current rating: See table I. Frequency: 60 hertz. Calibration: At +25C. Enclosure for overload, endurance, and short circuit tests: Cutler-Hammer loadcenter, or equivale

7、nt. TABLE I. Part or Identifying Numbers (PINs) and current rating. Government PIN Current rating WC375/19-001 10 WC375/19-002 15 WC375/19-003 20 WC375/19-004 25 WC375/19-005 30 WC375/19-006 35 WC375/19-007 40 WC375/19-008 50 WC375/19-009 60 WC375/19-010 70 WC375/19-011 100 TABLE II. Supersession an

8、d cross reference. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-C-375/19C 4 The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only a

9、nd the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. MILITARY INTE

10、RESTS: CIVIL AGENCY COORDINATING ACTIVITIES: Custodians: GSA - FSS Navy - YD Air Force - 85 Preparing activity: DLA - CC DLA - CC Review activities: Project 5925-2009-011 Navy - MC, OS Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document.

11、Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Government PIN Superseded CAGE 74193 WC375/19-001 X0411-10-120-60-9 0411-10-120-60-9 WC375/19-002 X0411-15-120-60-9 0411-15-120-

12、60-9 WC375/19-003 X0411-20-120-60-9 0411-20-120-60-9 WC375/19-004 X0411-25-120-60-9 0411-25-120-60-9 WC375/19-005 X0411-30-120-60-9 0411-30-120-60-9 WC375/19-006 X0411-35-120-60-9 0411-35-120-60-9 WC375/19-007 X0411-40-120-60-9 0411-40-120-60-9 WC375/19-008 X0411-50-120-60-9 0411-50-120-60-9 WC375/19-009 X0411-60-120-60-9 0411-60-120-60-9 WC375/19-010 X0411-70-120-60-9 0411-70-120-60-9 WC375/19-011 X0411-100-120-60-9 0411-100-120-60-9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM D228-2006 Standard Test Methods for Sampling Testing and Analysis of Asphalt Roll Roofing Cap Sheets and Shingles Used in Roofing and Waterproofing《铺屋顶和防水用沥青卷屋顶层、外覆薄板和盖屋板的抽样、试.pdf ASTM D228-2006 Standard Test Methods for Sampling Testing and Analysis of Asphalt Roll Roofing Cap Sheets and Shingles Used in Roofing and Waterproofing《铺屋顶和防水用沥青卷屋顶层、外覆薄板和盖屋板的抽样、试.pdf
  • ASTM D228-2008 Standard Test Methods for Sampling Testing and Analysis of Asphalt Roll Roofing Cap Sheets and Shingles Used in Roofing and Waterproofing.pdf ASTM D228-2008 Standard Test Methods for Sampling Testing and Analysis of Asphalt Roll Roofing Cap Sheets and Shingles Used in Roofing and Waterproofing.pdf
  • ASTM D2281-1968(2005) Standard Test Method for Evaluation of Wetting Agents by the Skein Test《用绞纱试验评定润湿剂的标准试验方法》.pdf ASTM D2281-1968(2005) Standard Test Method for Evaluation of Wetting Agents by the Skein Test《用绞纱试验评定润湿剂的标准试验方法》.pdf
  • ASTM D2281-2010 Standard Test Method for Evaluation of Wetting Agents by the Skein Test《用纱线试验法评价润湿剂的标准试验方法》.pdf ASTM D2281-2010 Standard Test Method for Evaluation of Wetting Agents by the Skein Test《用纱线试验法评价润湿剂的标准试验方法》.pdf
  • ASTM D2281-2010(2016) Standard Test Method for Evaluation of Wetting Agents by the Skein Test《采用绞纱试验法评估湿润剂的标准试验方法》.pdf ASTM D2281-2010(2016) Standard Test Method for Evaluation of Wetting Agents by the Skein Test《采用绞纱试验法评估湿润剂的标准试验方法》.pdf
  • ASTM D2284-2011 Standard Test Method for Acidity of Sulfur Hexafluoride《六氟化硫酸度的标准测试方法》.pdf ASTM D2284-2011 Standard Test Method for Acidity of Sulfur Hexafluoride《六氟化硫酸度的标准测试方法》.pdf
  • ASTM D2287-1996(2001) Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds《非刚性氯乙烯聚合物和共聚物模塑和挤压复合物(X-15-360)第19项(X-15-372-1)规范》.pdf ASTM D2287-1996(2001) Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds《非刚性氯乙烯聚合物和共聚物模塑和挤压复合物(X-15-360)第19项(X-15-372-1)规范》.pdf
  • ASTM D2287-1996(2010) Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds《非硬性氯乙烯聚合物与共聚物的模塑及挤压化合物的标准规范》.pdf ASTM D2287-1996(2010) Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds《非硬性氯乙烯聚合物与共聚物的模塑及挤压化合物的标准规范》.pdf
  • ASTM D2287-2011 Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds《非刚性氯乙烯聚合物和共聚物模制及挤压化合物的标准规格》.pdf ASTM D2287-2011 Standard Specification for Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds《非刚性氯乙烯聚合物和共聚物模制及挤压化合物的标准规格》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1