1、 A-A-5LLO 66 W 7777774 OOLOO7 b M tLC,d/r- / A-A- 5 18 10 4 February 1987 COMMERCIAL ITEM DESCRIPTION TIMER, INTERVAL The General Services Administration has authorized the use of this commercial item description. This commercial item description covers one type of interval timer for laboratory use

2、 Salient characteristics: Shall be an electrically powered, four-channel timer controlled by a quartz crystal for accuracy consisting of three countdown timing channels and a fourth channel which shall display the time of day. The countdown timing channels shall be capable of being set from 20 hour

3、s to one second. Each channel shall have a distinct tone and visible alarm which sounds and blinks until it has been shut off. Channel displays shall be 13 millimeter high LED display digits and shall operate on 120 volts A.C. at a frequency of 60 Hertz. The unit shall be approximately 2 inches (5.0

4、 cm) high by 7 inches (17.5 cm.) wide by 4 inches (10.0 cm.1 deep and housed in an ABS plastic case. Each unit shall have operating instructions which are neat and legible. Shall be in conformance with Under- writers Laboratory Standard 1222. Workmanship. The interval timer shall be free from defect

5、s which detract from its appearance or impair its serviceability. Unit. Each (EA). One interval timer as specified, constitutes one unit. Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance f all inspection re

6、quirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to p

7、erform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. AMSC N/A FSC 6645 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. 1 of 3 Provided by IHSNot f

8、or ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A- 5 1 8 1 O Records. Records of examinations and tests performed by or for the contractor shall be maintained by the contractor and made available to the Government upon the Governments request, at any time, or from tim

9、e to time, during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. Inspections. Inspections, as used herein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appl

10、iances or procedures) and testing (determination by technical means of physical and chemical properties) of the item, Samplinq for inspection. Sampling for inspection shall be conducted in accordance with MIL-STD-105. Where feasible, the same sample shall be used for the determination of two or more

11、 inspection character- istics* Unless otherwise specified, sampling for examination shall be conducted at inspection level S-2, AQL 2.5, and sampling for tests (when applicable) shall be conducted at inspection level 8-3, AQL 1.0. Tests. Tests shall be conducted to determine compliance with specific

12、ation requirements. Where feasible, the same sample shall be used for the determination of two or more test characteristics. Contractor certification. The contractor shall certify that the product offered meets the salient characteristics of this description and conforms to the producers own drawing

13、s, specifications, standards, and quality assurance practices. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Regulatory requirements. If the product covered by this

14、document has been determined by the U.S. Food and Drug Administration to be under its jurisdiction, the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of the Federal Food, Drug and Cosmetic Act, as amended, and regulations pr

15、omulgated thereunder. In addition, the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of all other applicable Federal, State, and local statutes, ordinances, and regulations. Federal Food, Drug and Cosmetic Act. 2 Provided by

16、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-SLLO bb M 7777774 OOLOBLL Li A-A- 5 18 10 Recovered materials. The offeror/contractor is encouraged to use recovered material in accordance with Public Law 94-580 to the maximum extent practical. Preservation,

17、 packaqing, packing, labeling, and marking. Unless otherwise specified, preservation, packaging, and packing shall be to a degree of protection to preclude damage to containers and/or contents thereof under normal shipping conditions, handling, etc:, involving shipment from-the supply source to the

18、receiving activity, plus reshipment from receiving activity, and shall conform to applicable carriers rules and regulations. package quantities and labeling and marking shall be as specified in the contract and/or order. Intermediate and exterior For information only. The following National Stock Nu

19、mber is covered by this document: 6645-01-212-9474 TIMER, INTERVAL Ordering data. and marking must be specified in the contract and/or order). (Intermediate/exterior package quantities and labeling MILITARY INTERESTS: Custodians: Army - MD Navy - MS Air Force - 03 CIVIL AGENCY COORDINATING ACTIVITY: VA - OSS PREPARING ACTIVITY: DoD-MB Agent: DLA-DM Project No. 6645-0375 CID-timer-interval-9474 3 U.1. I0VCIII)ILNT ?RKNTIN1 OFFXCE: 1117 - 704-01117OJOO Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN VDE 0611-4-1991 Terminal blocks for connecting copper conductors distribution terminal blocks up to 6 mm《铜导体连接用端子接线板 第4部分 面积可达 6 mm (上标2) 配电端子接线板》.pdf DIN VDE 0611-4-1991 Terminal blocks for connecting copper conductors distribution terminal blocks up to 6 mm《铜导体连接用端子接线板 第4部分 面积可达 6 mm (上标2) 配电端子接线板》.pdf
  • DIN VDE 0618-1-1989 Equipment for equipotential bonding equipotential busher for main equipotential bonding《等电位连接设备 第1部分 等电位主连接用等电位套管》.pdf DIN VDE 0618-1-1989 Equipment for equipotential bonding equipotential busher for main equipotential bonding《等电位连接设备 第1部分 等电位主连接用等电位套管》.pdf
  • DIN VDE 0623-589-2011 Plug device for battery powered industrial trucks Type 80 160 320 640 150 V - Part 589 Dimensions of plug device material marking《工业用机动车辆插头 80 160 320 640 150.pdf DIN VDE 0623-589-2011 Plug device for battery powered industrial trucks Type 80 160 320 640 150 V - Part 589 Dimensions of plug device material marking《工业用机动车辆插头 80 160 320 640 150.pdf
  • DIN VDE 0630-12-1988 Switches for appliances for a rated voltage not exceeding 500 V and a rated current not exceeding 63 A electronic switches《额定电压不超过 500 V 和额定电流不超过 63 A 的设备开关 第1.pdf DIN VDE 0630-12-1988 Switches for appliances for a rated voltage not exceeding 500 V and a rated current not exceeding 63 A electronic switches《额定电压不超过 500 V 和额定电流不超过 63 A 的设备开关 第1.pdf
  • DIN VDE 0636-3-2013 Low-voltage fuses Part 3 Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) Examples of sta.pdf DIN VDE 0636-3-2013 Low-voltage fuses Part 3 Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) Examples of sta.pdf
  • DIN VDE 0641-21-2011 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 21 Selective main circuit-breakers《电工器件 家用过.pdf DIN VDE 0641-21-2011 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 21 Selective main circuit-breakers《电工器件 家用过.pdf
  • DIN VDE 0660-112-1987 Switchgear and controlgear additional specification for d c air-break switches air-break disconnectors and air-break switch-disconnectors exceeds 1200 V but n.pdf DIN VDE 0660-112-1987 Switchgear and controlgear additional specification for d c air-break switches air-break disconnectors and air-break switch-disconnectors exceeds 1200 V but n.pdf
  • DIN VDE 0660-209-1988 Switchgear and controlgear low voltage switchgear and controlgear additional requirements for proximity position switches for safety functions《开关装置和控制装置 低压开关装.pdf DIN VDE 0660-209-1988 Switchgear and controlgear low voltage switchgear and controlgear additional requirements for proximity position switches for safety functions《开关装置和控制装置 低压开关装.pdf
  • DIN VDE 0661-10 A2-2011 Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs) German version HD 6.pdf DIN VDE 0661-10 A2-2011 Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs) German version HD 6.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1