1、e A-A-54785 = 9999974 03235bO b4T A-A-54 7 8 5 8 January 1993 COMMERCIAL ITEM DESCRIPTION MANOMETER, SPINAL FWID The General Services Administration has authorized the use of this Commercial Item Description as a replacement for Military Specification MIL-M-36958 which is cancelled. This Commercial

2、Item Description covers one type of a sterile disposable spinal fluid manometer suitable for measuring spinal fluid pressure. t characteristics: piaterial. The manometer set shall be manufactured from a rigid or semi-rigid plastic. The plastic shall be inert to blood and common IV fluids and meet th

3、e requirements of the USP for class II plastics. Stvle. desian and dimensions. The manometer set shall be in accordance with Figure 1. The stopcock shall be Type I (3-Way) or Type II (4-Way) as shown in Figure 1. The capillary tube shall be calibrated from 3 cm (30 mm) to 55.0 cm (550 mm) minimum. T

4、he scale shall be marked in 2 millimeter graduations with main graduations every 3, centimeter (10 mm). The stopcock and capillary tube shall be furnished with plastic protectors on each connector which shall maintain sterility of the fluid path until removed. Eerformaance, The manometer set shall b

5、e suitable for use in measuring spinal fluid pressure during spinal anesthesia procedures. Manometer sets shall be tested for freedom from pyrogens, leakage, clear passage of fluid, and security of assembly . AMSC N/A FSC 6515 DISTRI BUTION STATEMENT A. distribution is unlimited. Approved for public

6、 release; Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5 4785 = 9999974 OL2L5bl 58b = A-A- 5 4 7 8 5 Ster ilitv. The manometer set shall be sterile in accordance with USP or AAMI guidelines. shall be 0.000001. Sterility Assurance Level Freedom

7、 fr om Dvr ouens. The manometer set shall be free from pyrogens when tested in accordance with the USP. alternate to the USP Pyrogen Test, the USP Bacterial Endotoxin Test (LAL) may be used. As an Instructions f or use. proper use of the manometer set shall be provided with each individual manometer

8、 A detailed instruction sheet for yorknian chi D. free from parting lines. The manometer set shall be free from flash, pitting, cracks, holes or any foreign matter. The stopcock shall be free from any defects which affects its appearance or utility. mt. Package (PG). One package containing ten indi

9、vidually packaged sterile spinal fluid manometers, as specified, constitutes one unit. The individual package shall be a sealed peel-open type container capable of maintaining sterility of contents unless the package is damaged or opened. use shall be supplied with each unit. The Luer tapers and rot

10、ating plug shall be Complete and detailed instructions for 9UALITY ASSURANCE PRO VISIONS. JtesDonsibili tv for in sDection Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except otherw

11、ise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the s

12、pecification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. for the contractor shall be maintained by the contractor and made available to the Government upon the Governments request, at any time, or from time to time, during the perfo

13、rmance of the contract and for a period of three years after delivery of the supplies to which such records relate. Records. Records of examinations and tests performed by or 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54785 m 9999974 01215

14、62 412 m A-A-54 7 8 5 mriection. Inspec ion, as used herein, is defined as both examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) of the item. Tests.

15、 Tests shall be conducted to determine compliance with specification requirements. where feasible, the same sample shall be used for the determination of two or more test characteristics. mnlina for tests. Sampling for tests shall be conducted in accordance with MIL-STD-105 and as specified herein.

16、Unit of product for test purposes shall be one manometer set. Sampling shall be Inspection level S-l. A test failure shall be cause for rejection. Clear ria ssaae of fl uid. The manometer set shall be tested as an assembly. Each of the three or four fluid paths shall be tested using water or another

17、 suitable test fluid. shall be applied to the fluid path at a pressure of 3-1/2 & 1/2 psig .and shall pass freely through all of the ports within three (3) seconds of application utilizing the gages specified in IS0 Standard 594. Test fluid mue. The manometer set assembly shall be tested for leakage

18、 in accordance with IS0 Standard 594. the testing may consist of an pneumatic circuit equivalent to IS0 Standard 594 except that air shall be applied at a pressure of 10 psi. As an alternate, Any leakage shall be a test failure. Security of Assemblv of stoDcock. The stopcock body shall be secured. A

19、 25 lb. axial force shall be applied to the rotating plug arm for one (1) minute. Any stopcock which breaks or in which any component separates shall be considered a test failure. 3 c1 I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54785 W 999

20、9974 0121563 359 A-A-54 78 5 Metric Drodu cts . Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, providing they fall within the tolerance specified using conversion tables contained in the latest revision of Federal Stand

21、ard No. 376, and all other requirements of this document are met. If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch/pound units, a request should be made to the contracting officer to determine if the product is acceptable. The contrac

22、ting officer has the option of accepting or rejecting the product. Contractor Certifbtion. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this Commercial Item Description, and that the product conforms to the producers

23、own drawings, specifications, standards, and quality assurance practices. The government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Reaulatorv reuuirements. Federal Fo od. Drua.

24、 and Cosmetic Act. If the product covereL by this document has been determined by the U.S. Food and Drug Administration to be under its jurisdiction , the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of the Federal Food, Dr

25、ug, and Cosmetic Act, as amended, and regulations promulgated thereunder. In addition, the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of all other applicable Federal, State, and local statutes, ordinances, and regulations

26、 use recovered material in accordance with Federal Acquisition Regulation Subpart 23.4 to the maximum extent practical. Pecover ed material. The offeror/contractor is encouraged to 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54 7 8 5 prese

27、rvation. packauina. packing. Weling. and markina. Unless otherwise specified, preservation, packaging, and packing shall be to a degree of protection to preclude damage to containers and/or contents thereof under normal shipping conditions, handling, etc:, involving shipment from the supply source t

28、o the receiving activity, plus reshipment from receiving activity, and shall conform to applicable carriers rules and regulations. Intermediate and exterior package quantities and labeling and marking shall be as specified in the contract and/or order. Orderina dat a. (Intermediate/exterior package

29、quantities and labeling and marking must be specified in the contract and/or order . ) NOTE 1: document : The following National Stock Number is covered by this ” Item Identificata 6515-00-782-2620 MANOMETER, SPINAL FLUID, WATER TYPE, Disposable. NOTE 2: through the American National Standards Insti

30、tute (ANSI), 11 West 42nd Street, New York, NY 10036. Copies of IS0 Standards 594/1 and 594/2 may be obtained MILITARY INTERESTS: PREPARZNG ACTIVITY: Custodians: DoD-MB Army-MD Navy-MS Air Force-O3 Agent: DLA-DM CIVIL AGENCY COORDINATING ACTIVITIES: VA-OSS USPHS FDA-MPQAS Project No. 6515-5333 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A- 54785 A-A-54785 I 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1