ECA 520CAAB-A-1992 Detail Specification for Sensitive Switches Single Break Contacts Miniature Size《超小尺寸单开路触点灵敏开关详细规范》.pdf

上传人:roleaisle130 文档编号:704071 上传时间:2019-01-03 格式:PDF 页数:21 大小:876.03KB
下载 相关 举报
ECA 520CAAB-A-1992 Detail Specification for Sensitive Switches Single Break Contacts Miniature Size《超小尺寸单开路触点灵敏开关详细规范》.pdf_第1页
第1页 / 共21页
ECA 520CAAB-A-1992 Detail Specification for Sensitive Switches Single Break Contacts Miniature Size《超小尺寸单开路触点灵敏开关详细规范》.pdf_第2页
第2页 / 共21页
ECA 520CAAB-A-1992 Detail Specification for Sensitive Switches Single Break Contacts Miniature Size《超小尺寸单开路触点灵敏开关详细规范》.pdf_第3页
第3页 / 共21页
ECA 520CAAB-A-1992 Detail Specification for Sensitive Switches Single Break Contacts Miniature Size《超小尺寸单开路触点灵敏开关详细规范》.pdf_第4页
第4页 / 共21页
ECA 520CAAB-A-1992 Detail Specification for Sensitive Switches Single Break Contacts Miniature Size《超小尺寸单开路触点灵敏开关详细规范》.pdf_第5页
第5页 / 共21页
点击查看更多>>
资源描述

1、EIA 520CAAB-A 92 m 3234600 0500633 4 m - Reproduced By GLOBAL ENGINEERING DOCUMENTS With Thr Permission of EIA Under Royalty Agreement ANSI1 EIA-52 OCA AB- A- 19 91 APPROVED: September 20,1991 EIA SPECIFICATION Detail Specification for Sensitive Switches, Single Break Contacts, Miniature Size MARCH

2、1992 ELECTRONIC IN DUSTRI ES ASSOCIATION ENGINEERING DEPARTMENT Amroved For Use In The NECQ Svstem EIA 520CAAB-A 92 W 3234600 O500632 b 4 NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purcha

3、sers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of EIA from

4、manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members, whether the standard is to be used either domestically or internationally. r Recommended Stand

5、ards and Publications are adopted by EIA without regard to whether their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard o

6、r Publication. This EIA Standard is considered to have international Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC document can be made. This Standard does not purp

7、ort to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standard

8、s Proposal No. 2234-A formulated under the cognizance of the P-13.3 Subcommittee on Sensitive, Pushbutton and Keyboard Switches) Published by ELECTRON IC IN DUSTRIES ASSOCIATION Engineering Department 2001 Pennsylvania Ave. N.W., Washington, D.C. 20006 PRICE: Please refer to the current Catalog of E

9、IA ) POSITION (. 10.31 406 f ,005 0.13 1 w* 22.23 f0.13 4 ( ,875 f .O052 I., 6o 29.46 MAX c- I +- I 2.79 f 0.51 (.i I f 00020) NOTES : (a) Dimensions are denoted as follows: . 0.0 = mm (b) Yetric dimensions are based upon 1.0 inch = 25,4 millimeters, (ci Unless otherwise noted, inch dimension tolera

10、nces are: 0.00 = inches One place (,O) = 2,030 Two place (.O01 = 2.015 Three place (.O001 = 2.005 (d) Fineness of rounding (inch to millimeter) tolerances: Inch Tolerance 2.0000 to 2.00016 2.00016 to 2,OOlb 2 .O016 to 2 ,016 2,016 to 2.16 Derived Millimeter Tolerance Rounded to the nearest: 0,0001 (

11、4 decimal placesi 0.001 (3 decimal places, 0,Ol (2 decical places) 0.1 il decimal place) (e) htounting holes will accept pins or screws of 2.84 mm (,112 inch) naximum diameter, PI- 1 - IyHTaTIIG DI!fEMSIOES ABD 1 ACTATR (PII PLEEt) EIA 520CAAB-A 92 m 3234600 0500640 5 m EIA-52OCAAB-A - Page 7 . 4*1

12、* OS5* WIDE LEVER LI6“ ;iwl*($;, Type 2 - Straight Lever 3.05 f 0.38R r(. I20 f .015) Type 4 - Simulated Roller Lever 4083 WIOE ROLLER u Type 3 - Roller Lever TYPE FIGURE 2 - ACTUATOR DIMENSIONS D LMENS ION “A“ LEVER LENGTH mm inch LEVER STYLE 1 21.34 ,840 2 35.71 I. 406 3 59.44 2.340 1 20.57 .810 2

13、 34.11 I. 343 1 32.64 1.285 EIA-520CAAB-A Page 8 TYPE 1 - Quick Connect Terminals (must accept AMP 187 Series receptacles) A MAX TYPE 3 7.62 (.300) 7.11 (.280) TYPE 4 8.43 (.332) 7.92 (.312) Screw Terminals (4-40 NC Round or Binder Head) X TYPE 2 - Quick Connect Terminals (must accept AMP 250 Series

14、 receptacles) A“ MAX- + Solder Terminals NOTE: The dashed lines represent the maximum permissible envelope dimensions for the terminals, FIGURE 3 - TERHINA type 2, style 3 and Type 4, style 1 units each of electrical rating codes A and B i units each of electrical rating codes A, B, G il Group 1 uni

15、ts Group 1 units Group 1 units Types 6 il units 2 units 21 at +85 C units 2 units 2 units 2 Perf ormance requirements (see Note A) see Table V R 5 ,050 S2 R 2 1000 M2 leakage A5 SOOVA leakage AS 500a1A - within limits within limits 10 or 25 grams no damage no damage no damage no sticks/misses S 3OoC

16、 see Table V leakage S 500vA no damage no stickc/misses S 30C leakage S 500A see Table V .I EIA-5 2 OCAAB-A EIA 52OCAAB-A 92 m 3234lbOO 0500644 2 m- Page 11 f TABLE II- QUALIFICATION APPROVAL INSPECTION TESTS (cont,) Test numbe r and test designation (see Note A) GROUP 1B (destructive 1 9-1 Overload

17、 8-3 Electrical endurance 4-1 Temperature rise 3-2 Alt, voltage proof 1-6 Operating char, GROUP 2 (destructive) 10-2 Thermal shock 5-3 Vibration 5-2 Shock 10-1 Humidity 1-6 Operating character. 3-1 Voltage proof GROUP 3 (destructive) Resistance to soldering heat 6-3 Strength of screw mtg 1-6 Operati

18、ng character. 3-1 Voltage proof GROUP 4 (destructive ) 10-6 Low temp, operation 7-1 Mech, endurance 1-6 Operating character, 2-1 Switch resistance GROUP 5 (destructive) 10-4 Salt spray GROUP 6 (destructive) 16-1 Flammability Conditions of test (see Note A) 50 cycles 25,000 cycles 100 V, 50,000 ft -5

19、5C b +85C 10-500 Hz, 10 g 50 g, sawtooth 1000 Vac per EIA-448-22 0,4 Nm 1000 Vac -55 c i ,000,000 cycles -55 *C/+85 C 6 V, 100 mA 96 hours ;ample size, sample description, I criterion or accepability (See Note B) sample description units 2 units 2 at 50,000 ft units 2 units 121 units 2 units each 31

20、 units each 3 units of type designation O1 or 40 units of type designation O1 or 40 units of terminal type 6 units each 41 ?lect, rating code G only units each 5 Perf o rmance requirements (see Note A) io damage io stickclmisses 30.C leakage 5 500vA see Table V io damage 10 vs maximum 10 sis maximum

21、 see Table V leakage AS 500M no damage see Table V Leakage AS 500vA no delay no damage see Table V R S ,050 Q KEY: t.d, = maximum permissible number of defective units per test g,d. = maximum permissible number of defective units per test group, EIA 520CAAB-A_92 - 3234b00 05.00b45 4 = EIA-520CAAB-A

22、9 Page 12 NOTES: i Group 1 test samples may be any type designation providing the following are tested: - contact arrangement: form i; - terminal styles: Types 1, 2, h and 6 - actuators: Type 1; type 2, style 3; and type 4, style 1 - Electrical rating codes: A, B and G, 7 Group 1X and 1B test sample

23、s Ray be any type designation providing the following are tested: - contact arrangement: forni C 3 Group 2 test samples may be any type designation providing the following are tested: - contact arrangement: form C - teminal styles: Types 1 and 3 - actuators: Types 1 and 3 - electrical rating code: A

24、, B ;ii $I Group 4 test samples may be any type designation providing the following are tested: - contact arrangement: form C - discrete identification: 01, 11 and 15 5 Group 5 test samples aay be any type designation providing the following are tested: - contact arrangement: form A and B - discrete

25、 identification: 03 and ?O 6 Test samples shall be in accordance with ANSI/UL 34, a .EIA 520CAAB-A 92 3234600 0500bqb b EIA-SSOCAAB-A _ - Page 13 Test number and test designation see Note 1) GROUP A (non-destructive). 1-1 Visual examination major ninor 2-1 Switch resistance relect. rating code H onl

26、y) 1-5 Functional operation 3-1 Voltage proof 1-6 Operating characteristics 2.4 Quality conformance inspection AQL 1 O 1.5 0.65 0.65 0.65 0.65 NOTES : 1: The number of the test and performance requirenents refer to the generic specification for electromechanical switches. EIA 5200000 with the supple

27、mentaw requirements specified in this document, ?: AQL = acceptable quality level TABLE IV - MAJOR CHARACTERISTICS FOR VISUAL EXANINATION Characteristics Audible snap Physical damage Proper termination Proper lever leaf 1 attachment Proper roller attachment Actuator Type xx EIA-520CAAB-A Page 14 TAR

28、LE V - PERIODIC INSPECTION TESTS test number and test designation see Note A) GROUP B idest ruc tive 1 11-1 Solderability - - GROUP C 1. destruct ive 3-1 Electrical endurance see note Ci G-1 Temperature rise 3-1 Voltage proof GROUP E !destructive (Re-qu, Conditions Of test ;see Note Ai 100,000 cycle

29、s 1000 Vac lif ication per T 1 Sample size. saspie description, Perforzance i 5r criterion or accepability requirenents i see Note AI p n sample description t i? 4 units of terminai O j I ype ij Il 12 5 each elec. rating !see note 1) ! !no sticks Tisses I Ileakage 5 5001iA I I Il SOTES : 1: Group C

30、test samples may be any type designation providing the following are tested: - contact arrangement: form C - electrical ratiiig code: A, B arid G A: The number of the test and performance requirements refer to the generic specification for electromechanical switches, EIA 5300000. with the supplement

31、ary requirements specified in this document. B: In the groups, all specimens shall be subjected to the required tests and all tests shall be performed in the sequence shown. C: The electrical endurance test shall be limited to the xaximum current rating at standard atmospheric conditions. D: In this

32、 table: n = sample size t = total acceptance criterion (permitted number of defectives for one or several groups combined e,g. Group O, Group 1, Group 3 to Group ij inclusive). p = periodicity in aonths. EIA 520CAAB-A 92 m 3234600 0500648 - T EIA-520CAAB-A Page 15 T w O o ta I s ic.i h - c.( C - n h

33、 N N N 3 - 3 h hCI CIO7 T -0 ri o O Oh 9“ T O v 3 - I “cz I l i CI I I u! o i U Li EIA 520CAAB-A 72 m 3234600 0500647 II m EIA-520CAAB-A Page 16 u - O CI 9 (1 + CO .4 212 j . + ?I -ri- :i; O0 !I5 2.1% 39 -I $ S! I III .; I EIA 520CAAB-A 92 W 3234b00 05OOb50 = EIA-520CAAB-A Page 17 I I I E ln I- “/“

34、CN CI C4 h 9 h 9 O CI - z n E CLI 3 h c1 - O Ln 3 O0 slp O0 97 I: 1- =-+ qp CI - QI CI CI 2 - 13 N I cv + e .T I I .n CI I O ,3 I h U I I EIA 520CAAB-A 92 W 3234b00 0500b53 T 1 O EIA STANDARD AND SPECIFICATION NUMBERING I STAN DARD Standard or Generic Specification Standard Prefix for all Numbers Se

35、ctional Specification Designator -zl- A document that establishes engineering and technical requirements for processes, procedures, practices and methods that have been decreed by authority or adopted by consensus. Standards may also be established for selection, application and design criteria for

36、material. Standards and other documents not in the specification format use only the EIA basic numbering system as follows: EIA-123 . Original Standard EIA-I 23-1 Addendum to Original Standard EIA-123-A First Revision of original Standard incorporating all Addenda SPECIFICATION A document prepared s

37、pecifically to facilitate procurement which clearly and accurately describes the essential technical requirements for purchased material. Procedures necessary to determine that the requirements for the purchased material covered by the specification have been met shall also be referenced or included

38、. EIA Specifications use the following system: EIA I230000 EIA 123A000 EIA 123AAOO EIA 123W EIA 123OOAA is a Generic Specification is a Sectional Specification is a Blank Detail Specification is a Detail Specification is a Detail Specification for which no Sectional or Blank Detail Specification was issued. NOTES: 1. Some older specifications may not have been converted to this numbering system. 2. See EP-11 “Guide for the Preparation of Specification Using IECQ-System Format,“ for more detail.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1