1、 EIA STANDARD Lead Taping of Components in Axial Lead Configuration for Automatic Handling EIA-296-F March 2015 ANSI/EIA-296-F(2015) Approved: March 27, 2015 EIA-296-F NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings be

2、tween manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any me

3、mber or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or inte

4、rnationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Public

5、ation. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC document can be made. This Standard does not purport to a

6、ddress all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Propos

7、al No. 4518, formulated under the cognizance of the National Standards Committee for Automated Component Handling and reaffirmed under Standards Project Number 5319). Published by Electronic Components Industry Association 2015 Standards Table 1 and associated paragraphs 5.1 through 5.10. 4.2 Reelin

8、g and optional fan fold packaging of taped axial leaded components are defined in Figure 2, Table 2 and associated paragraphs 6.1 through 6.4. 4.3 Dimensions contained in this Standard are expressed in metric terms with English equivalents. Metric dimensions shall govern. EIA-296-F Page 2 4.4 Procur

9、ement documents and quotation requests should include the following minimum information: (a) Reference to this Standard by title and number. (b) Inside tape spacing and component pitch. (c) Taping quality requirements including maximum number of missing parts if different than Paragraph 5.7. (d) Ree

10、l or Fan Fold packaging (e) Container and reel marking requirements if different than specified in paragraph 6.2 of this document. EIA-296-F Page 3 5.0 LEAD TAPING REQUIREMENTS FIGURE 1W L3 T H A M S P B L1 L2 W L3 L1 L2A H P T M B S EIA-296-F Page 4 TABLE 1 EIA-296-F Page 5 5.1 Leads shall not be b

11、ent beyond 1.0mm (.039) for “B“ dimension of 26mm or 1.2mm (.047) for all other “B“ dimensions from their nominal position when measured between the center line of the component lead at the inside tape edge and the center line of the lead egress from the component. 5.2 Splicing tapes or clips are pe

12、rmissible provided they do not degrade the strength or handling characteristics of the taped component. Staples shall not be used. The splicing tapes shall be of equal strength to the original tape and shall overlap a minimum of 50.8mm (2.0) in each direction of the break in the tape being joined. T

13、ape splices shall not allow any misalignment greater than 0.8mm (.031). 5.3 A minimum 200mm (7.87) leader shall be provided at both ends of each finished length of taped components. 5.4 Nominal tape width (“T“, Figure 1) shall be from 5.0mm (.197) to 6.35mm (.25) or 9mm (.354), provided that variati

14、on in the width of the tape used does not exceed 0.4mm (.015). 5.5 Protection between layers of taped components shall be provided for the length necessary to prevent component damage or lead distortion. All materials used for lead taping, reeling and packaging shall not cause deterioration of the c

15、omponent or lead solderability. 5.6 All polarized components must be oriented in the same direction. The cathode lead tape(s) shall be colored and the anode tape(s) shall be white. 5.7 Empty spaces in the tape (i.e., missing components) shall not exceed 0.1% of the total number of components per con

16、tainer. No consecutive missing components are allowed. 5.8 For special cases where Table 1 does not apply the maximum tape spacing (B, Figure 1) shall not exceed 122mm (4.803); its value shall be chosen in relation to the component dimensions. 5.9 Components shall be held sufficiently in the tape or

17、 tapes so that they cannot come free in normal handling. 5.10 The maximum component body diameter must be less than the nominal component pitch. EIA-296-F Page 6 5 REELING/FAN FOLD (AMMO) PACKAGING REQUIREMENTS xyzchdaMarking see paragraph 6.2Reel PackingFan Fold Option See Paragraph 4.4Marking see

18、paragraph 6.2FIGURE 2 EIA-296-F Page 7 TABLE 2 DESCRIPTION NOTATION DIMENSIONS FLANGE DIAMETER d 76.2mm(3.0) to 355.6mm(14.0) ARBOR HOLE a 13.9mm(0.547) to 38.1mm(1.50) INSIDE FLANGE SPACING c See Paragraph 6.4 CORE DIAMETER (O.D.) h 34.0mm(1.374) to 92.1mm (3.626) FAN FOLD PACK WIDTH x 51mm (2.008)

19、 Max. for 26mm (1.024) tape spacing (B, Figure 1) 85mm (3.346) Max. for 52.4mm (2.063) tape spacing (B, Figure 1) FAN FOLD PACK LENGTH y 255mm (10.039) Max. FAN FOLD PACK HEIGHT z 122mm (4.803) Max. EIA-296-F Page 8 6.1 The packaging material and processes shall not adversely affect the mechanical o

20、r electrical characteristics or marking of the components. 6.2 Minimum reel and fan fold pack label marking shall consist of: Customer part number Customer traceability number Quantity of Components Manufacturers Names and optional Trademark Taping/Packaging Date Date Codes (where applicable) Vendor

21、 Type or Part Number Electrical Value (where applicable) Tolerance (where applicable) Polarity (where applicable) 6.3 Quantity of taped components shall be controlled so that the components and final cover shall not extend beyond the smallest dimension of the package (reel or fan fold pack). 6.4 The

22、 “c“ dimension between the reel flanges, as shown in Figure 2 shall be governed by the overall width “W“ of the taped component as shown in Figure 1. The “C“ dimension between the flanges of the component reel shall be 1.5mm (0.059) to 8.0mm (0.315) greater than the overall taped component width “W“

23、. ECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA Standards & Technology Depart

24、ment 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c. Reason/Rationale

25、 for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org