ECA EIA-364-115-2016 TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets.pdf

上传人:刘芸 文档编号:704221 上传时间:2019-01-03 格式:PDF 页数:11 大小:189.35KB
下载 相关 举报
ECA EIA-364-115-2016 TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets.pdf_第1页
第1页 / 共11页
ECA EIA-364-115-2016 TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets.pdf_第2页
第2页 / 共11页
ECA EIA-364-115-2016 TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets.pdf_第3页
第3页 / 共11页
ECA EIA-364-115-2016 TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets.pdf_第4页
第4页 / 共11页
ECA EIA-364-115-2016 TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、 EIA STANDARD TP-115 Current Overload Test Procedure for Electrical Connectors and Sockets EIA-364-115 April 2016 Electronic Components Industry Association ANSI/EIA-364-115-2016 Approved: April 28, 2016 EIA-364-115 NOTICE EIA Engineering Standards and Publications are designed to serve the public i

2、nterest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publi

3、cations shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the st

4、andard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation wha

5、tever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC document

6、 can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory l

7、imitations before its use. (From Standards Proposal No. 5335, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry Association 2016 EIA Standards but also not act as a heat absorber that might transfer h

8、eat, via conduction, away from the DUT. EIA-364-115 Page 2 3 Test specimen DUT contacts should be of the same material and should have a finish indicative of the normal production unit. DUT contacts should be connected to wiring in the manner typical for this product and wired in series. DUT contact

9、s shall be loaded into non-adjacent cavities in normal connector housing/shell. 4 Test procedure 4.1 One cycle of test shall be as specified in table 1. DUT shall complete 24 cycles, without interruption. 4.2 DUT contacts and inserts shall exhibit no evidence of material deterioration or performance

10、 degradation. 4.3 The connector contacts shall be installed in ten random, nonadjacent cavities and shall be subjected to 24 uninterrupted cycles of the current profile specified in table 1, unless otherwise specified in the referencing document. At completion of test sequence, DUT contacts and conn

11、ector shall be examined for evidence of material deterioration or performance degradation as defined in the referencing document. Table 1 Current level Current level Time, minutes 2X full rated current 5 Full rated current 55 5 Details to be specified The following details shall be specified in the

12、referencing document: 5.1 What connector insert is to be used 5.2 What mounting termination is to be used 5.3 Location of any temperature sensors on the test item, if applicable. 5.4 Full rated current for each type of contact to be tested 5.5 What constitutes performance degradation 5.6 Number of c

13、ycles to be completed, if other than 24 EIA-364-115 Page 3 6 Test documentation Documentation shall contain the details specified in clause 5, (when provided), and the following: 6.1 Title of test 6.2 The type of connector used 6.3 The type of termination 6.4 Test equipment used, and date of last an

14、d next calibration 6.5 Test procedure 6.6 Other items as required 6.7 Values and observations 6.8 Name of operator and start/finish date(s) of test ECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons,

15、 please fill in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA Standards & Technology Department 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Ad

16、dress: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c.Reason/Rationale for Recomendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Revision History Revision letter Project number Publication date Additions, changes and deletions - SP-5335 Initial publication. Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1