资源描述

1、 EIA STANDARD TP-24B Maintenance Aging Test Procedure for Electrical Connectors EIA-364-24B (Revision of EIA-364-24A) May 1998 ANSI/EIA-364-24B-1998(R2015) Approved: February 5, 1998 Reaffirmed: March 23, 2015 EIA-364-24B NOTICE EIA Engineering Standards and Publications are designed to serve the pu

2、blic interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and

3、 Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether

4、the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligati

5、on whatever to parties adopting the Standard or Publication. This standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC documen

6、t can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory

7、limitations before its use. (From Standards Proposal No. 3990 formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards, and reaffirmed per Standards Proposal No. 5345.07). Published by Electronic Components Industry Association 2015 Standards & Technolog

8、y Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. Fo

9、r information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5184), International (303-397-7956) CONTENTS Clause Page 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Scope . 1 2 Test resources .

10、. . . . . I 2.1 Equipment . . 1 3 Test specimen . . . . . . . . . . . . . . . . . . . . . . . 1 3.1 Description . . . . . . . . . . . . . . . . . . . . . 1 3 .2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4 Test procedure . . .

11、. . . . . . . . . . . . . . . . . . . . . 2 5 Details to be specified . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6 Test documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 TEST PROCEDURE No. 24B MAINTENANCE AGING TEST PROCEDURE FOR ELECTRICAL CONNECTORS EIA-364-24B P

12、age 1 (From EIA Standards Proposal No. 3990, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards.) 1 Introduction 1.1 Scope This standard establishes a test method to assess the ability of a component to withstand stresses caused by repeated insertion and extraction

13、of contacts during maintenance. This test procedure applies only to connector assemblies containing removable contacts and is to be used where a connector is to be stressed in the area of contact retention and conductor sealing. 2 Test resources 2.1 Equipment 2.1.1 Test equipment shall consist ofthe

14、 insertion and removal tools specified. 2.1.2 A force gage of suitable range for the force being measured, so that the reading shall lie in the middle 50 percent of the scale, where practicable, with a nominal accuracy of 2 percent. 3 Test specimen 3.1 Description A test specimen shall consist of a

15、connector with all contacts installed and wired according to the referencing document. 3.2 Preparation All rear hardware or accessories should be loosened or removed to permit extraction and insertion of contacts. The accessories shall remain loose or removed during the test. EIA-364-24B Page2 4 Tes

16、t procedure 4.1 Unless otherwise specified, select 20% ofthe contacts, but no fewer than six, at random from each specimen for test. For connectors having six or fewer contacts, all contacts shall be used for the test. At least one contact shall be in or near the center of the connector. Unless othe

17、rwise specified, there shall be ten extraction and insertion cycles for each contact. The force required to insert and remove each contact in and from the connector shall be measured during the initial and final maintenance aging cycle in accordance with EIA-364-05. 4 .1.1 Record the following initi

18、al measurements, if specified 4 .1.1.1 Contact retention force. 4 .1.1.2 Contact insertion and extraction force. 4 .1.2 Record the following final measurements, if specified 4 .1.2.1 Contact retention force. 4.1.2.2 Contact insertion and extraction force. 4.1.2.3 Visual examination for damage to wir

19、e seals, etc. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Design or type of insertion and extraction tools see 2.1.1 5.2 Test specimen preparation see 3.1 5.3 Number of test cycles, if other than 1 0 see 4.1 5.4 Number of samples to be tested 5

20、. 5 Requirements for initial measurements 5. 6 Requirements for final measurements 5. 7 Degradation allowed due to maintenance aging test 6 Test documentation EIA-364-24B Page3 Documentation shall contain the details specified in clause 5, with any exceptions, and the following: 6.1 Title oftest 6.2

21、 Sample description, including fixturing if applicable 6.3 Test equipment used, and date oflast and next calibration 6.4 Test procedure 6.5 Values and observations 6.6 Name of operator and date of test ECIA Document Improvement Proposal If in the review or use of this document, a potential change is

22、 made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA Standards & Technology Department 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Titl

23、e: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org