1、 EIA STANDARD TP-81A Combustion Characteristics Test Procedure for Electrical Connector Housings, Connector Assemblies and Sockets EIA-364-81A (Revision of EIA-364-81) March 2005 Electronic Components Industry Association EIA-364-81A ANSI/EIA-364-81A-2005 (R2017) Approved: March 17, 2005 Reaffirmed:
2、 January 23, 2017 NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtainin
3、g with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such St
4、andards and Publications preclude their voluntary use by those other than ECIA members, whether the Standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such
5、 action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implications, but the International Electrotechnical Commission activity
6、has not progressed to the point where a valid comparison between the EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard t
7、o establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5373.05, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards) Published by Electronic Comp
8、onents Industry Association 2017 EIA Standards see figure 1. Figure 1 - Test setup 45 Holding fixture Test specimen Free end Burner EIA-364-81A Page 6 4.6 The test flame shall be applied for 10 seconds, unless otherwise specified in the referencing document. 4.6 1 After the 10 seconds application th
9、e test flame shall be removed a minimum of 152 millimeters (6 inches) from the point of application. 4.6.2 In the event of flaming or glowing of the test specimen, the duration of said flaming and glowing shall be noted and recorded. Dripping of molten and/or flaming material and igniting of the lay
10、er of cotton, if occurring, shall be noted and recorded. 4.6.3 To distinguish between flaming and glowing, a small piece of surgical cotton (50 millimeters square) shall be brought into the area in question. Ignition of the cotton shall be indicative of flaming. 4.7 The flame shall be reapplied for
11、10 seconds in accordance with 4.5 and 4.6. The flame shall be immediately applied after the first application or when the flaming or glowing ceases to exist, if occurring on the first application. 4.8 If the test specimen drips molten and/or flaming material during the flame application, the burner
12、may be tilted to an angle up to 45 degrees and slightly removed to the specimen side to avoid material dripping into the burner tube. 4.8.1 The 9.5 millimeters (0.38 inch) distance between the bottom of the test specimen and top pf the burner tube shall be maintained. 4.8.2 Any molten “strings“ of m
13、aterial are to be ignored and the flame is to be applied to the major portion of the specimen. 4.9 Charring, melting etc., of the test specimen shall be ignored. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Configuration to be tested 5.2 Conditi
14、oning classification 5.3 Requirements 5.4 Clamping technique 5.5 Final measurements and requirements 5.6 Flame application time, if other than 10 seconds EIA-364-81A Page 7 6 Test documentation Documentation shall contain the details specified in clause 5, with any exceptions, and the following: 6.1
15、 Title of test 6.2 Test equipment used, and date of last and next calibration 6.3 Connector description, including material and connector length 6.4 Duration of flaming after each flame application 6.5 Duration of glowing after each flame application 6.6 Name of operator and date of test ii EIA Docu
16、ment Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Electronic Industries Alliance Technology Strategy & Standards Department Publications
17、Office 2500 Wilson Blvd. Arlington, VA 22201 FAX: (703-875-8906) Document No. Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and/or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR EIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org