资源描述

1、 EIA STANDARD TP-97 Housing Panel Retention Test Procedure for Insulation for Electrical Connectors EIA-364-97 June 1997 ANSI/EIA-364-97-1997(R2015) Approved: April 22, 1997 Reaffirmed: March 27, 2015 EIA-364-97NOTICE EIA Engineering Standards and Publications are designed to serve the public intere

2、st through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publicatio

3、ns shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standar

4、d is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever

5、 to parties adopting the Standard or Publication. This EIA standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progresses to the point where a valid comparison between the EIA Standard and the IEC document can b

6、e made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitat

7、ions before its use. (From Standards Proposal No. 5083, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards, and reaffirmed per Standards Proposal No. 5347.02). Published by Electronic Components Industry Association 2015 Standards & Technology Depa

8、rtment 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For info

9、rmation, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5184), International (303-397-7956) CONTENTS Clause Page 1 Introduction . 2 Test resources . . 2.1 Equipment . 1 3 Test specimen I 4 Test procedure . . . . . . . . . . . . . . . . . . . . . . . . .

10、 . . . . . . . . . . . . . . . . . . . . 1 4.1 Preparation 1 4.2 Mounting . 2 4.3 Force application . 2 4.4 Failure mode . 2 5 Details to be specified . . . . . . . . . . . 2 6 Test documentation . 2 Figure I Typical test fixture : . 3 1 Introduction TEST PROCEDURE No. 97 HOUSING PANEL RETENTION TES

11、T PROCEDURE FOR ELECTRICAL CONNECTORS EIA-364-97 Page 1 This specification covers the test procedure for determining the mechanical retention of the panel locking feature housings when installed in panels. 2 Test resources 2.1 Equipment Apparatus shall include the following: 2.1.1 Panel cutout for e

12、ach size housing, fabricated within the drawing tolerances specified in the Detail Specification. 2.1.2 Force mechanism capable of compression testing at a constant rate of 12.7 millimeters per minute (0.5 inch per minute). 2.1.3 Compression force measuring device capable of measuring force to an ac

13、curacy of 2%. 3 Test specimen Housing sizes from the connector family shall be as specified in the Detail Specification. 4 Test procedure 4.1 Preparation Each connector housing shall be properly installed in the appropriate panel cutout. Each connector housing size shall be tested in the direction a

14、gainst the housing panel lock. Previous page is blank EIA-364-97 Page2 4.2 Mounting The mounted connector housing and panel cutout shall be placed on appropriate blocks, fixture, etc., as shown in figure 1. 4.3 Force application The force mechanism shall be set to exert an axial force at a constant

15、rate of 13 millimeters per minute (0.5 inch per minute) in a direction against the connector housing panel locks, thus causing the connector housing to be dislodged from its mounted position in the panel. 4.4 Failure mode Maximum retention force, visual observations, and resultant and failure mode s

16、hall be recorded. 5 Details to be specified The following details shall be specified in the Detail Specification: 5.1 Sizes and numbers ofhousings to be tested. 5.2 Direction of force application required for test, if other than indicated in figure 1. 5.3 Minimum housing panel retention force. 5.4 S

17、equence of conditioning and testing if applicable. 5.5 Conditions if other than standard atmospheric conditions. 6 Test documentation Documentation shall contain the following: 6.1 Title of test. 6.2 Description of specimen and fixture - including dimension of each panel cutout used. 6.3 Test eqUipm

18、ent used. 6.4 Maximum retention force and other observations. 6.5 Ambient temperature and humidity. 6.6 Name of operator and date of test. Panel With Cutout Support EIA-364-97 Page 3 r Direction of Force Application Applied over Majority of Surface Area Typical Connector Figure 1 - Typical test fiXt

19、ure Support Sufficient Space to Allow Housing to be Dislodged From Panel ECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Elect

20、ronic Components Industry Association EIA Standards & Technology Department 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Cla

21、use Number and /or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org