ECA EIA-520DAAA-1990 Detail Specification on 1 Pole Toggle Switches《1极扳扭开关的详细规范》.pdf

上传人:figureissue185 文档编号:704394 上传时间:2019-01-03 格式:PDF 页数:18 大小:692.41KB
下载 相关 举报
ECA EIA-520DAAA-1990 Detail Specification on 1 Pole Toggle Switches《1极扳扭开关的详细规范》.pdf_第1页
第1页 / 共18页
ECA EIA-520DAAA-1990 Detail Specification on 1 Pole Toggle Switches《1极扳扭开关的详细规范》.pdf_第2页
第2页 / 共18页
ECA EIA-520DAAA-1990 Detail Specification on 1 Pole Toggle Switches《1极扳扭开关的详细规范》.pdf_第3页
第3页 / 共18页
ECA EIA-520DAAA-1990 Detail Specification on 1 Pole Toggle Switches《1极扳扭开关的详细规范》.pdf_第4页
第4页 / 共18页
ECA EIA-520DAAA-1990 Detail Specification on 1 Pole Toggle Switches《1极扳扭开关的详细规范》.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、I r z ?. a EIA 520DAAA 90 = 3234b00 0073471 ANSI/ EIA-520DAAA-19 90 APPROVED: May 18, 1990 EIA SPECIFICATION Detail Specification on 1 Pole Toggle Switches E IA-52 O DAAA JUNE 1990 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT Amroved For Use In The NECQ Svstern EIA 520DAAA 90 W 3234600 0

2、073472 T EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum d

3、elay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publi

4、cations preclude their voluntary cise by those other than EIA members, whether the standard is to be used either domestically OP internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or p

5、rocesses. By such action, ElA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This EIA Specification ia considered to have International Standardization implication, but the International Elect

6、roteehnical Commission activity has not progressed to the point where a valid comparison between the EIA Specification and the IEC document can be made. This Specification does not purport %o address all safety problema associated with ita use or all applicable regulatory requirements. It is the res

7、ponsibility of the user of this Specification to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From EIA Standards Proposal No. 2193 formulated cinder the cognizance of the EIA P- -13.2 Subcommittee on Toggle, Rocker, P

8、addle S25082-C21 1 FIGURE 4 - HEX NUT DIMENSIONS FIGURE 5 - INTERNAL TOOTH LOCKWASHER DIMENSIONS EIA 520DAAA 90 m 3234600 0073481 O m EIA-5 2 ODAAA Page 9 i830.40 . (.IS* ,016) 1.0 0c-O.OS (p 4 O* -003) MATERIAL QQ-S- 698 RiIL HARDWARE CAN BE REPLACED BY RIS25081-4 STEEL FINISH CADMIUM PLATE QQ-P-41

9、6, TYPE II, CLASS 3 I I I 1 MATERIAL 1 FED STD NO. 66 CRES FINISH I PASSIVATE MIL HARDWARE I CAN BE REPLACED BY MS2508l-C4 FIGURE 6 - KEYING WASHER DIMENSIONS 7. I (,f e) (.2 7 3+ .O171 H&)f 4 / II L .lHw- 32UNC-2A LCONTOUR OPT. MATERIAL QQ-B-626, ALLOY NO. 360, HALF HARD FINISH SILVER OR TIN PLATE

10、MIL HARDWARE NONE SCREW (BRASS) NAT ER IA L QQ-B-750. COkIP A FINISH SILVER OR TIN PLATE ?dIL HAEDWARE NONE LO C K VA SHE R (PHos FIGURE 7 - SCREW WITH CAPTIVE INTERNAL TOOTH LOCKWASHER DIMENSIONS e EIA SZBDAAA 90 3234600 0073482 2 W CRES EIA-520DM DaCe 10 MA TE RIAL FED STD NO. 66 RIIL HARDWARE CAN

11、 BE REPLACED BY hIs51957-41 (. 164-32) F“KISH - MS51957-26 ( ,138-32) t0.00 1.95k 0.15 , . 6.35-0.80 i THREAD SIZE .138-32UNC- 2 A 6.7020.20 (.2 632.007) I CRES MA TERIA L 1 FED STD NO. 66 FINISH I PASSIVATED FIGURE 8 - PAN EEAB SCREW DIMENSIONS BRONZE 1 3.70*0.20 (, I46iz.O 05) RIA TER IA L QQ-B750

12、, COhIPOSITION A, HARD FINISH CADhIIUh1 PLATE QQ-P-416, TYPE II, CLASS 3 NS35338-98 ( .138) hlIL HARDWARE CAS BE REPLACED BY hlS35338-99 .164) i MAX (.2 53) .0 71.15 (.034+.003) MATERIAL QQ-S-700 STEEL FINISH CADMIUM PLATE QQ-P-416, TYFE II, CLASS 3 NlS35338-41 (.138) R4s35338-42 (.164) I hlIL HARDW

13、ARE CAN BE REPLACED i3Y b I 1 bL 1 EIA 520DAAA 90 = 3234600 0073483 4 E IA- 5 2 ODAAA Page 11 1.9 Ratings and Characteristics 1.9.1 Ratings Altitude Electrical - power - logic level - low level Flammability Fluid resistance Fungus resistance Icing Moisture resistance Random vibration Salt Spray Sand

14、 and Dust Sealing Shock Temperature Thermal Shock Vibration 1.9.2 Characteristics Actuator grounding Altitude voltage proof see note 11 Capacitance Contact bounce EM1 shielding Endurance - electrical (at high temp. - logic level - low level - mechanical and at 65,000 ft) Explosion Immersion in clean

15、ing solvents Insulation resistance Mass including mounting hardware Operating characteristics - Total travel - Operating force Overload Resistance to soldering heat Solderability Strength of - actuator - mounting bushing 65,000 ft See Table II not applicable not applicable applicable not applicable

16、applicable not app 1 ica b 1 e applicable not applicable 96 hours applicable watertight immersion 75 G, half-sine -55C to 70C -55C to 125C 10 G, 10-500 HZ not applicable 500 Vrms not applicable not applicable not applicable 20,000 cycles with no sticks or misses not applicable not applicable 40,000

17、cycles applicable. See clause 1.10.1. not applicable not applicable 0.11 pound maximum See Figure 1 not applicable applicable applicable to solder terminals only applicable to solder terminals only 25 pounds 15 pound-inches EIA 520DAAA 90 3234600 0073Li84 6 m EIA-5 20DU Page 12 1 2 Strength of termi

18、nation - IWTS - screw - solder Switch resistance Temperature rise - at 6,000 cycles - at 20,000 cycles Voltage proof see note 11 resistive inductive lamp load resistive inductive lamp load a 20 15 5 15 10 3 15 10 4 15 7 2 15 lb for 5-10 s 5 pound-inches 5 pound not applicable 30C maximum 50C maximum

19、 1500 Vac NOTE I: After electrical endurance testing, the points of application of the test voltage shall be from terminals to ground only. 1.10 Increased severities or requirements which are additional to those specified in the qeneric and/or sectional specification 1.10.1 Explosion Object: The obj

20、ective of the test is to assess whether a switch, while operating, will ignite an ambient explosive atmosphere prevalent in aircraft applications. This test is not necessary for switches which are enclosed in housings (casings) designed to prevent flame or explosion propagation. Test Method: Switche

21、s shall be tested in accordance with Method 109 of MIL-STD-202. Switches shall be operated at their maximum rated dc inductive current at the rated voltage. Criteria: The explosive mixture in the test chamber surrounding and external to the switch shall not explode whether or not an explosion occurs

22、 within the switch. Switches shall be electrically operable after the test. TABLE II - ELECTRICAL RATING CODES I CODE 1 current capacity (amperes) I 28 Vdc 1 115 Vac, 60 & 400 Hz 1 EIA 520DAAA 90 3234600 0073485 8 W EIA-5 2 ODAAA Page 13 SECTION TWO - INSPECTIOM REQUIREMENTS 2. Inspection Requiremen

23、ts 2.1 Qualification Approval inspection requirements shall be in accordance with Table III for multiple product approvals. 2.2 Quality Conformance Inspection requirements are prescribed in Table IV for lot-by-lot inspections and Table VI for periodic inspections. For visual examination, the clarifi

24、cation of major and minor defects shall be in accordance with Table V. TABLE III - QUALIPICATIO TEST FOR MULTIPLE PRODUCT APPROVAL Test Method & Test Group GROUP A (non-destructive) Visual examination Dimensions Mass Functional operation Operating characteristics Voltage proof GROUP B (destructive)

25、Solderability Strength of terminations Strength of actuator Overload Elect. endurance-high temp. Elect. endurance-altitude Temperature rise Voltage proof Operating characteristics Sealing-Watertight immersion Group C (destructive) Thermal Shock Vibration Shock Moisture resistance Operating character

26、istics Voltage Proof Sealing-Watertight immersion Test NO. 1-1 1-2 1-4 1-5 1-6 3-1 11-1 6-4 6-1 9-1 8-2 8-3 4-1 3-1 1-6 14-1 10-2 5-3 5-2 10-1 1-6 3-1 14-1 Test Samples all units ri1 111 all units all units all units 4 units having solder 4 units of each terminal 4 units of each toggle terminals sty

27、le lever style r21 r21 21 all units from Test 8-2 all Group B samples all Group B samples all Group B samples 4 units each of O1 and 07 switching circuits 4 units each of O1 and 07 switching circuits 4 units each of O1 and 07 switching circuits 4 units each terminal style all Group C samples all Gro

28、up C samples all Group C samples t.d O O O O O O O O O O O O O O O O O O O O O O O EIA 520DAAA 90 3234600 0073486 T W 1-1 1-5 3-1 1-6 EIA-5 2 ODU Page 14 ND ND ND ND TABLE III (csnt.) QUALIFICATION TEST POR MULTIPLE PRODUCT APPROVAL Test Method & Test Group GROUP D (destructive) Strength of mtg. bus

29、hing Operating characteristics Voltage Proof GROUP E (destructive) Mechanical endurance operating characteristics Sealing-Watertight immersion GROUP F (destructive) Salt Spray GROUP J (destructive) Flammability GROUP K (destructive) Explosion Test NO. 6-2 1-6 3-1 7-1 1-6 14-1 10-4 16-1 -lause 1.10 1

30、 Test Samples 4 units of any type designation all Group D samples all Group D samples 4 units each of O1 and 07 switching circuits all Group E samples all Group E samples 2 units of each terminal style 31 2 units of electrical rating code 1 t.d. O O O O O O O O O O O O g.d. O KEY: t.d. = maximum per

31、missible number of defective units per test g.d. = maximum permissible number of defective units per test group, 2 units each of each terminal configuration and each toggle lever style, 2 uiiits each of switching circuits O1 and 07 for each electrical load. Test samples shall be in accordance b7th A

32、NSI/UL 94. TABLE IV - LOT-BY-LOT INSPECTION TESTS TEST ID“ TEST METHOD i TEST GROUP INO. 1 “ND GROUP A (lot-by-lot) Visual examination Major Minor Functional operation Voltage proof Operating characteristics E standard toggle lever EIA 520DAAA 90 3234600 0073487 L = lever-lock toggle lever EIA-5 2 O

33、DAAA Page 15 solder terminal TABU3 V - MAJOR CHARACTERISTICS FOR VISUAL EXAMIATIOI IWTS Characteristic X X X X properly assembled physical damage keyway location properly marked proper lever assembly proper locking a r r a n g eine n t smooth, even terminal plating gauge check of terminals X X X X X

34、 X X X X X X X screw terminal X X X X TABLE VI - PERIODIC IISPECTIOIS Test Method & Test Group GROUP X (every 12 months) Dimensions Mass Solderability Electrical endurance at altitude 11 Temperature rise Voltage proof Operating characteristics Sealing-Watertight immersion GROUP Y (every 36 months) T

35、hermal Shock Vibration Shock Moisture Operating characteristic Voltage proof Sealing-Watertight immersion Test NO. 1-2 1-4 11-1 8-13 4-1 3-1 1-6 14-1 10-2 5-3 5-2 10-1 1-6 3-1 14-1 Test Samples 2 units of EIA520DAAA-07X2 11 Il II II II 11 II 11 Il II II Il Il Il 4 units of EIA520DAAA-OlX3 11 II IS 1

36、1 Il Il 11 II II 11 II II t.d. O O O O O O O O O O O O O O O g.d. NOTES Il - Electrical load shall be 28 Vdc, 10 amperes inductive load. t.d. = maximum permissible number of defective units per test. g.d. = maximum permissible number of defective units per group. o EIA 520DAAA 90 m 3234600 O073488 3

37、 EIA STANDARD AND SPECIFICATION NUMBERING i STANDARD A document that establishes engineering and technical requirements for processes, procedures, practices and methods that have been decreed by authority or adopted by consensus. Standards may also be established for selection, application and desig

38、n criteria for material. Standards and other documents not in the specification format use only the EIA basic numbering system as follows: EIA-123 Original Standard EIA-123-1 Addendum to Original Standard EIA-123-A First Revision of original Standard incorporating all Addenda SPECIFICATION A documen

39、t prepared specifically to facilitate procurement which clearly and accurately describes the essential technical requirements for purchased material. Procedures necessary to determine that the requirements for the purchased material covered by the specification have been met shall also be referenced

40、 or included. EIA Specifications use the following system: Standard or Generic Specification Standard Prefix for all Numbers Sectional Specification Designator Blank Detail Specification Designator -zJ A - A - Detail Specification Designator EIA 1230000 EIA 123A000 EIA 123AAOO EIA 123AAAA EIA 123OOA

41、A is a Generic Specification is a Sectional Specification is a Blank Detail Specification is a Detail Specification is a Detail Specification for which no Sectional or Blank Detail Specification was issued. NOTES: 1. Some older specifications may not have been converted to this numbering system. 2. See EP-11 “Guide for the Preparation of Specification Using IECQ-System Format,“ for more detail.

展开阅读全文