ECA IS-43AE-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Nonplenum Cable《LAN双绞线数据通信用电缆-2类non-Plenum电缆的详细规范》.pdf

上传人:livefirmly316 文档编号:704525 上传时间:2019-01-03 格式:PDF 页数:18 大小:486.99KB
下载 相关 举报
ECA IS-43AE-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Nonplenum Cable《LAN双绞线数据通信用电缆-2类non-Plenum电缆的详细规范》.pdf_第1页
第1页 / 共18页
ECA IS-43AE-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Nonplenum Cable《LAN双绞线数据通信用电缆-2类non-Plenum电缆的详细规范》.pdf_第2页
第2页 / 共18页
ECA IS-43AE-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Nonplenum Cable《LAN双绞线数据通信用电缆-2类non-Plenum电缆的详细规范》.pdf_第3页
第3页 / 共18页
ECA IS-43AE-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Nonplenum Cable《LAN双绞线数据通信用电缆-2类non-Plenum电缆的详细规范》.pdf_第4页
第4页 / 共18页
ECA IS-43AE-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Nonplenum Cable《LAN双绞线数据通信用电缆-2类non-Plenum电缆的详细规范》.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、EIA IS-43AE 8 = 3234600 0002467 3 / EIA SPECIFICATION Cable For LAN Twisted Pair Data Communications - Detail Specif cation For Type 2, Nonplenum Cable NQ-EIAAS-43AE SEPTEMBER 1988 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT NOTICE EIA Engineering Standards and Publications are designed

2、 to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of su

3、ch Standards and Pub- lications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA

4、members, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to

5、 any patent owner, nor does it assume any obligation whatever to parties adopting the Recom- mended Standard or Publication. Copyright 1988 Pu bl ished by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Depart ment 2001 Eye Street, N.W. Washington, D.C. 20006 PRICE: $11.00 Published in U.S.A. EIA IS-4

6、3AE 88 W 3234600 O002469 7 W System Standard Organization Electronic Industries Association Omnibus Specification Number: EIA/IS-43 Electronic Components of assessed quality in accordance with: Outline Drawing: Cross Section Tinned Copoer Braioez Sn,ed (8) VMG Insulated Conductors Rip Cord (4) DMG C

7、onductor insulation- y Oplional Black Heat - Barrier Tape (12) No. 22 AWG Solid Copper Conductors Metal Backed Taoe Polyester Tape (2) Polyester Tape (0.05) Thick (4) VGM Twisted Pair - Outer Jacket IL Separation by hletal Backed Tape 13 Maximum Type 2 Non-Pienum Detail Specification Number I I I I

8、I I I I I I I I I I I I I I NQ-EIA/IS-43AE Blank Detail Specification: I None Product Description Exchange Cable for use With Data Processing Equipment Type 2 Nonplenum Cable Two Insulated Data Grade Media (DGM) and Four Voice I Grade Media (VGM) Copper I Conductors in a PVC Jacket I I I I I I Elect

9、rical Circuit i I I I I I I Typical Construction Application/Assessment Level I Assessment Level: C Performance Grade: IEEE 802.5 I I I I Information on the availablility of components i I qualified to this specification is given in I the Qualified Products List. I I 1.0 Scope and Objective 1 1.1 Sc

10、ope . 1 1. 2 Objective . 1 2.0 General Data . 1 2.1 General 1 2.2 Ordering Information . 1 3.0 Specific Cable Requirements . 3.1 Configuration 3.1.1 Conductors . 3.1 . 1.1 Data Grade Media (DG?) 3.1.1.2 Voice Grade Media (VGM) 3.1.1.3 Twist of VGM Pairs 3.1.2 Shields . 3.1.3 Fillers . 3.1.4 Rip Cord

11、 3.1.5 Jacket . 3.2 Electrical Specifications . . 3.2.1 Crosstalk 3.2.2 Impedance 3.2.3 Attenuation . 3.2.4 DC: Resistance of Conductors 3.3 Cable Mechanical Specifications 3.3.1 Mechanical Tests 3.3.2 Safety Requirements . 3.3.3 Core Flammability 3.4 Inspection Requirements . ii NQ-EIA/IS-43AE CONT

12、ENTS . 1 . 2 . 2 2 2 . 3 . 3 . 3 . 3 . 3 . 4 4 . 5 6 6 7 1 . 7 . 7 . 7 . 8 EIA IS-43AE :* I I I I I 1kHz I NS I 600 I i 9.6 kHz i 270 i N S i I 10 kHz I N S I 188 I I 38.4 kHz I 185 I N S I I 40 kHz I N S I 125 I I I I I I I I I I I i 256 kHz N S 105 I I I I I 4 MHz I - I 100 I I- l I I 3 to 20 b1Hz

13、;kI 150 I N S I 1 I I I N S = NOT SPECIFIED * The specification must be met over the entire frequency range specified. *;y 15% tolerance except 25% for 4 NHz NQ-EIA/IS-4 3AE Page 6 3.2.3 ATTENUATION i I I ATTENUATION I (Flax Allowable dB/km) I I I I 1 Frequemcy I DGFI I VGM i I I i 1 1 kHz 1 N S I 1

14、.28 I I 9.6 kHz I 3 I N S 1 I I I 7- I I 38.4 kHz I 5 i N S i 1 150 kHz I N S I 7.13 I I 772 kHz I N S I 16.82 1 I 4 MHz i 22 1 N S I I 16 NHz I 45 I N S I I I I l I I t I I I N S = NOT SPECIFIED 3.2.4 DC RESISTANCE OF CONDUCTORS I I I DC RESISTANCE I I (Max ohms/km) I I I I 57.1 I 57.1 I I DGM i VG

15、M l q I I I EIA IS-43AE 88 3234600 0002477 b m NQ-EIA/IS-43AE Page 7 3.3 CABLE MECHANICAL SPECIFICATIONS I t 3.3.1 MECHANICAL TESTS . I I SPECIFICATION I I I I I I Outer Dia /Tensile/ Bend ICompressionl Flex /Impact1 Imm I N I radius 1 I4 I # I JI 1 - 13 i 288 i 7.5 i 444 i 20 i 4.5 i I min max I l

16、cm I l I I I ! 3.3.2 SAFETY REQUIREMENTS The cable must be listed by an appropriate test agency as meeting the requirements of the National Electrical Code for tC!l“ cable. o 3.3.3 CORE FLAMMABILITY For this requirement, the DGFI and VGFl components of the cable, when removed from the cable outer ja

17、cket and wrappings must each pass U. L. s VW-1 Vertical Flame Test per U. L. Subject 1581. The DG?l pairs must remain within their aluminum and braided shields. - EIA IS-43AE 88 3234600 0002478 B 3.4 INSPECTION REQUIREMENTS NOTES: The following symbols are used in the table below: D = Destructive Te

18、st L = Lot by lot. No less frequent ND = Nondestrucive Test than every 50,000 ft. p = Period in Nonths n = Sample Size c = Number of Defects Allowed (O) = Designates paragraph no. from the Omnibus Spec. A = All Cable - iOOo of Finished Cable No designation indicates Detail Spec. paragraph no. Group

19、A Inspection (Lot by Lot) SECTION NO. & REQUIREEIENT 2.7.1(0) & 3.1.1.1 DGM Insulation and Cond. Dimens ions 2.7.1(0) & 3.1.1.2 VGPI Insulation and Cond. Dimensions & Color 3.1.1.3 Twist of V.GM Pairs 2.7.3(0) & 3.1.2 Shields 2.7.8.8(0) Insul. Res. I I III I i OR1 COSDITIOSS OF ip (n(clPERFOR?lANCE

20、I ND I TEST I I IREQUIREMETS I l i D 1 Manual Yeas. IL (IjOlStated in I I I 1 12.7.1(0) & I 1 I I 13.1.1.1 I I I I I III I III I I IjI I !I I I iii ! II I Ili I I i D I Manual !leas. IL IlOIStated in I I I I D I Manual Pleas. i D I Visual Inspect. I I l ND I Stated in I 4.17(0) i ! 12.7.1(0) i l 1 I

21、 j3.1.1.2 I III ! I I /i I L (liOiLay I I 12.7.12.2(0) One Time I D Fiin rad of 30cm I Core Bend Radius I Stated in I I I4.6.2(0) l l I I I I i 12.7.12.3(0) Humidity 1 D IStated in 4.8(0 I Cycle I I I I I I I I I l I I I IREQUIREYETS i i/ p I n I c 1 PERFOR?lANCE III I I l I I I 2.7.12(0) I III I I

22、I /i /i 1711I01 Stated in 1 12I1101 Stated in 1 I I 2.7.12(0) I III I III I II, I iz.(i)O1 Flust meet req. 1 I I I of 2.7.12(0) SL 1 1 I I i 2.7.13.3(0) I I III I i/ I I 1 Cycle I I I I I I I I I Ili I I I 8 (:I I 12.7.13.4(0) Temperature1 ND Stated in 4.9(0)11211101 Plust meet req. I 1 i I I of 2.7.12(0) i i I I I I 2.7.13.4(0) I I i i iii i ! ,il - EIA IS-43AE 88 M 3234b00 0002484 3 M