ECA IS-43AF-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Plenum Cable《LAN双绞线数据通信用电缆-2类Plenum电缆的详细规范》.pdf

上传人:boatfragile160 文档编号:704526 上传时间:2019-01-03 格式:PDF 页数:18 大小:495.33KB
下载 相关 举报
ECA IS-43AF-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Plenum Cable《LAN双绞线数据通信用电缆-2类Plenum电缆的详细规范》.pdf_第1页
第1页 / 共18页
ECA IS-43AF-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Plenum Cable《LAN双绞线数据通信用电缆-2类Plenum电缆的详细规范》.pdf_第2页
第2页 / 共18页
ECA IS-43AF-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Plenum Cable《LAN双绞线数据通信用电缆-2类Plenum电缆的详细规范》.pdf_第3页
第3页 / 共18页
ECA IS-43AF-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Plenum Cable《LAN双绞线数据通信用电缆-2类Plenum电缆的详细规范》.pdf_第4页
第4页 / 共18页
ECA IS-43AF-1988 Cable for LAN Twisted Pair Data Communications - Detail Specification for Type 2 Plenum Cable《LAN双绞线数据通信用电缆-2类Plenum电缆的详细规范》.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、- EIA IS-43AF 88 3234b00 0002485 5 H A-. EIA SPEC1 FIWTION Cable For LAN Twisted Pair Qata Communications - Detail Specif ication For Type 2, Plenum Cable SEPTEMBER 1988 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT , NOTICE EIA Engineering Standards and Publications are designed to serve

2、 the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standa

3、rds and Pub- lications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members,

4、whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any pate

5、nt owner, nor does it assume any obligation whatever to parties adopting the Recorn- mended Standard or Publication. Copyright 1988 Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N.W. Washington, D.C. 20006 PRICE: $11.00 Published in U.S.A. e e a EIA IS-43AF 8

6、8 m 3234b00 0002487 9 m NQ-EIA/IS-4 3AF I System Standard Organization IDetail Specification Number I NQ-EIA/IS-43AF Electronic Industries Association I I I I I I I I Omnibus Specification Number: EIA/IS-43 /Blank Detail Specification: None Electronic Components of assessed quality in accordance wit

7、h: I Outline Drawing: I Product Description Cross Section i 1 Exchange Cable for use I With Data Processing I Equipment I 7 Tinnr (8) VMG Insulated Conductors I Type 2 Plenum Cable I Two Insulated Data Grade wer I MetalBackedTape I Media (DGM) and Four I (VGM) Copper Conductor I Jacket I Electrical

8、Circuit Braided Shield 14) DMG Conductor Insulation PolyecterTape I Insulated Voice Grade Media Optional Black Heat I Pairs in a Fluorocarbon (12) No. 22 AWG Solid Copper Conductors (0.05) Thick (4) VGM Twisted Pair (2) Polyester Tape Separation by Metal Backed Tape Type 2 Plenum, ITypical Construct

9、ion I I I IApplication/Assessment Level I Assessment Level: C I Performance Grade: I I IEEE 802.5 I I I Information on the availablility of components I I qualified to this specification is given in I the Qualified Products List. I I i EIA IS-43AF 88 3234b00 0002q88 NQ-EIA/IS-43AF CONTENTS 1.0 Scope

10、 and objective . 1 1.1 Scope . 1 1.2 Objective . 1 2.0 General Data . 1 2.1 General 1 2.2 Ordering Information . 1 3.0 Specific Cable Requirements . 3.1 Configuration 3.1.1 Conductors . 3.1.1.1 Data Grade Media (DGM) 3.1.1.2 Voice Grade Media (VGM) 3.1.1.3 Twist of VGM Pairs . . 3.1.2 Shields . 3.1.

11、3 Fillers . 3.1.4 Rip Cord 3 1.5 Jacket . 3.2 Electrical Specifications . . 3.2.1 Crosstalk 3.2.3 Attenuation . 3.2.4 DC Resistance of Conductors 3.3 Cable Mechanical Specifications 3.3.1 Mechanical Tests 3.3.2 Safety Requirements . 3.2.2 Impedance 3.3.3 Core Flammability 3.4 Inspection Requirements

12、 . 2 . 2 2 2 . 3 . 3 . 3 . 3 . . 3 . 4 . 4 . 5 . 6 6 . .- 7 . 7 . 7 . 7 8 2 . EIA IS-43AF 88 m 3234b00 0002489 2 m NQ- EIA/I S- 4 3AF Page 1 1.0 SCOPE AND OBJECTIVE 1.1 SCOPE This Specification defines Type 2 Plenum cable used with the Token Ring LAN Cabling System. Type 2 P consists of 2 twisted pa

13、irs of Data Grade Media (DGM) shielded with aluminum tape and braided shields, all cabled into a single fluorocarbon jacketed assembly. The Cabling System is intended to be compatible with IEEE Standard 807.5. It is designed to be used as a total.building wiring system. The Cabling System may be use

14、d as the communications medium for a Token Ring Setxork as well as for other data equipment. Detail 1.2 OBJECTIVE The objective of the Detail Specification is to provide a document describing Type.2 P cable as a basis for certificacion under the SECQ system and for acquisition of conforming cable. O

15、 2.0 GENERAL DATA 2.1 GENERAL Cable provided under this Detail Specification shall conform to all general and specific requirements applicable to Type 2 P cable in Omnibus Specification EIA/IS-43, Exchange Cable for Use with Data Processing Equipment, and those requirements specified herein. 2.2 ORD

16、ERING INFORMATION Orders for cable covered by this Detail Specification shall include the following information: 1. Identification of cable type O 2. Length required 3. Special requirements of reel size or type 4. Other unique requirements not covered in this specification -. -. EIA IS-43AF 88 m 323

17、4b00 0002490 9 m NQ-EIA/IS-43AF Page 2 3.0 SPECIFIC CABLE RE4 3.1 CONFIGURATION 3.1.1 CONDUCTORS Cable Type 2 P contains of VGM . REME TS wo -witted pairs o DG!l and four tw-stec pa .rs 3.1.1.1 Data Grade Media (DGM) The wire gauge, insulation material, and thickness of the DGH conductors are as fol

18、lows: Wire Type * 1 I I I I I 1 kHz I N S I 600 I I I I I I 9.6 kHz I 270 I N S 1 i 10 kHz i N S i 188 e I I I I I 38.4 kHz I 185 I N S I I 40kHz I N S I 125 I 1 256 kHz I N S I 105 I t i I I I 4 FHz I - I 100 I I I I I I I 1 I I I 3 to 20 FlHz*l 150 I N S I NQ-EIA/IS-43AF Page 5 N S = NOT SPECIFIED

19、 %$ The specification must be met over the entire frequency range specified. %?* 15% tolerance except 25% for 4 NHz NQ-EIA/LS-43AF Page 6 3.2.3 ATTENUATION i I I ATTENUATION 1 (Max Allowable dB/km) I t I I I I I I I Frequency 1 DGM I VGM I I I I 1kHz i ! NS i 1.28 1 I 9.6 kHz i 3 i N S , I 38.4 kHz

20、i 5 1 N S I I 150 kHz I N S I 7.13 1 I 772 kHz I N S i 16.82 I I 4tMz i22 iNS I I 16 MHz i 45 i N S i I l I I I I I I I I I t I I N S = NOT SPECIFIED 3.2.4 DC RESISTANCE OF CONDUCTORS I I DC RESISTANCE I (Max ohms/km) DGM i VGM 1 I I 57.1 I 57.1 I I I EIA IS-43AF 88 m 3234600 0002495 8 m NQ-EIA/IS-4

21、3AF Page 7 3.3 CABLE MECHANICAL SPECIFICATIONS 3.3.1 MECHANICAL TESTS I i SPECIFICATION l I I I l I I Outer Dia Tensilel Bend. Icompressionl Flex I Impact1 I mm I N I radius I N I # I JI I min max I I-cm I I I I l I I l I I I I - 13 I 444 1 15 I 446 I ?O I 4.5 I 3.3.2 SAFETY REQUIREMENTS The cable m

22、ust be listed by an appropriate test agency as meeting the requirements of the National Electrical Code for “C?lP“ cable. O 3.3.3 CORE FLAMMABILITY For this requirement, the DGN and VG! components of the cable, when removed from the cable outer jacket and wrappings must each pass U. L.s VW-1 Vertica

23、l Flame Test per U. L. Subject 1581. The DGY pairs must remain within their aluminum and braided shields. EIA IS-43AF 8 W 3234600 000249b T W NQ-EIA/IS-43AF Page 8 3.4 INSPECTION REQUIREMENTS NOTES: The following symbols are used in the table below: D = Destructive Test ND = Nondestrucive Test p = P

24、eriod in Months n = Sample Size c = Number of Defects Allowed (O) = Designates paragraph no. from the Omnibus Spec. L = Lot by lot. No less frequent A = All Cable - 1000 of. than every 50,000 ft. Finished Cable No designation indicates Detail Spec. paragraph no. Group A Inspection (Lot by. Lot) r I

25、I I SECTION NO. .,I CONDITIONS OF I p I n I c I PERFORFIANCE I I I I I l ill III I !II 2.7.7(0) Reground I ND I Verification 1121 11 01 Sone allowed I I I 2.7.9(0) Braided ShieldlD I Use gauge block(l2ll!O( Stated in I 1 2.7.9(0) I II( i i - /12/1101 Stated in i 2.7.10 (O) Compatibility I D I With O

26、ther Parts II II I l II I !I - 112: 1 i II II i I II i II 1 II i II II II i Radius I IStated in Il II II ID I 2.7.11(0) DGFf Color I I 3.1.5 Jacket Color I D I Visual Inspect. i 121 1 I! I I 3.3.1 Tensile Strength I ND ITension of 444N 12!3 I Stated in 4.5(0)1 I I I 3.3.1 Ninimum Bend I ND IElin rad

27、 of 15cm 1121 1 I I 3.3.1 Compressive I ND Compress of 444Nl1211 Strength I Stated in II I 14.12(0) II II Ij I I 2.7.11(0) I 31 Stated in i l I I I 31 Stated in 3.1.51 l I l i I Dl Stated in I I .2.7.12(0) I l I - l I 01 Stated in I I 2.7.12(0) I I I l l I I I I I .- I III I I l EIA IS-43AF 8 3234b0

28、0 0002501 T NQ-EIA/IS-4 3AF Page 13 Group C (Periodic - continued) i I SECTION NO. 6r I REQUIREMEhT -1 I I i iii I i I I D OR I I hD I TE ST I 1 I IREQUIRENENTS I CONDITIOXS OF I p I n I c 1 PERFORMANCE . . I l l l III I III . . I I I I I III I I I I i i 11211101 Stated in I I I D 170 flexes 13.3.1 Flex I I Stated in 4.6(0)i i I i 2.7.12(0) i I II 1 I III !/i I I I i i iii I I EIA IS-q3AF 88 W 3234b00 0002502 1 - :4-