ECA RS-448-4-1980 Standard Test Methods for Electromechanical Switches (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) (Addendum 4 to RS-448)《机电开关标准测试方法 (逻辑(.pdf

上传人:ideacase155 文档编号:704551 上传时间:2019-01-03 格式:PDF 页数:8 大小:237.42KB
下载 相关 举报
ECA RS-448-4-1980 Standard Test Methods for Electromechanical Switches (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) (Addendum 4 to RS-448)《机电开关标准测试方法 (逻辑(.pdf_第1页
第1页 / 共8页
ECA RS-448-4-1980 Standard Test Methods for Electromechanical Switches (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) (Addendum 4 to RS-448)《机电开关标准测试方法 (逻辑(.pdf_第2页
第2页 / 共8页
ECA RS-448-4-1980 Standard Test Methods for Electromechanical Switches (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) (Addendum 4 to RS-448)《机电开关标准测试方法 (逻辑(.pdf_第3页
第3页 / 共8页
ECA RS-448-4-1980 Standard Test Methods for Electromechanical Switches (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) (Addendum 4 to RS-448)《机电开关标准测试方法 (逻辑(.pdf_第4页
第4页 / 共8页
ECA RS-448-4-1980 Standard Test Methods for Electromechanical Switches (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) (Addendum 4 to RS-448)《机电开关标准测试方法 (逻辑(.pdf_第5页
第5页 / 共8页
点击查看更多>>
资源描述

1、ANSI/EIA RS-448-4 - 1980 APPROVED OCTOBER 6, 1980 EIA STANDARD STANDARD TEST METHODS FOR ELECTROMECHANICAL SWITCHES (Test Methods for Logic (TTL) Level Endurance and Low Level Endurance) RS448.4 (Addendum No. 4 to RS-448) NOVEMBER 1980 Engineering Department ELECTRONIC INDUSTRIES ASSOCIATION - EIA 4

2、48-4 0 3234b00 0069093 4 M NOTICE EIA Engineering standards are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, faci- litating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with

3、 minimum delay the proper product for his particular need. Existence of such standards shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such standards, nor shall the existence of such standards preclude their voluntary use by

4、those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended standards are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liabilit

5、y to any patent owner, nor does it assume any obligation whatever to parties adopting the recommended standards. This EIA Recommended Standard is considered to have international stan- dardization implications, but the IEC (or ISO) activity has not progressed to the point where a valid comparison be

6、tween the EIA Recommended Standard and the IEC (or ISO) Recommendation can be made. Published by Engineering Department 2001 Eye Street, N.W., Washington, D.C. 20006 . ELECTRONIC INDUSTRIES ASSOCIATION Copyright 1980 ELECTRONIC INDUSTRIES ASSOCIATION All rights reserved PRICE: $4.00 Printed in U.S.A

7、. EIA 448-4 80 3234b00 00b9094 b = RS-448-4 Addendum 4 STANDARD TEST METHODS FOR LOGIC (TTL) LEVEL ENDURANCE AND LOW LEEL ENDURANCE (From EIA Standards Proposals No. 1424 and No. 1425 formulated under the cog- nizance of EIA Working Group P-5.9 on Non-Sensitive. Pushbutton and Keyboard Switches.) Th

8、is Standard is Addendum No. 4 to RS-448 covering logic level and low level endurance. The following test methods are included: (1) Logic (TTL) Level Endurance - Method 17 (2) Low Level Endurance - Method 18 -i- - EIA 448-4 80 m 3234600 0067095 8 I- RS-448-4 Addendum 4 INDEX OF TEST METHODS ELECTROME

9、CHANICAL SWITCHES can be found in EIA RS-448: Method 1 - Switch Resistance Method 2 - Capacitance Method Method Method 7 - Overload Method 8 - Electrical Endurance Method 9 - Mechanical Endurance Method 10 - High/Low Temperature Operation Method 11 - Actuator/Mounting Bushing Resistance Method 12 -

10、Shock Test (Specified Pulse) Method 13 - Monitoring Contact Chatter Method 14 - Sand and Dust 5 - Strength of Mounting Mass 6 - Terminal Temperature Rise This addendum forms part of EIA Standard RC-448,. The following Test Methods 4 .6 9 10 12 16 20 21 22 23 30 31 The,following Test Method can be fo

11、und in EIA RS-448-1: Method 15 - Contact Bounce 1 The following Test Method can be found in EIA RS-448-2: Method 16 - Environmental Effects for Machine Soldering The following Test Methods can be found in EIA RS-448-3: Method 3 - Chromaticity Method 4 - Transmittancy (Luminance) The following Test M

12、ethods can be found in EIA RS-448-4: Method 17 - Logic (TTL) Level Eildurance Method 18 - Low Level Endurance 1 1 2 1 1 - EIA 448-Li 0 m 3234b00 00b909b T m RS-448-4 Addendum 4 Page 1 METHOD 17 TEST METHOD FOR LOGIC (TTL) LEVEL ENDURANCE 1. PURPOSE The Logic Level Endurance Test is a measure of the

13、ability of a switch to control electrical loads in which the applied voltage exceeds the melting voltage of the switch contact material and is less than the arcing voltage and arcing current. Electronic logic circuits have defined interface signal voltages. Logic “O“ is a signal voltage between O an

14、d 0.9 volts. Logic “1“ is a signal voltage greater than 2.4 volts and less than 5.5 volts. 2. TEST CONDITIONS Each pair of switch contacts shall be tested using a 5.0 + 0.5 V dc, 10 + 1 mA resistive load. During each closure of the contacts, the voltage drop across the switch terminals shall be moni

15、tored for a .duration of no less than 50% of each contact static closure. The switch contacts need not be monitored until 10 milliseconds after the initial contact closure to exclude any contact bounce. During each opening of the contacts, the voltage drop across the switch terminals shall be monito

16、red for a duration of no less than 50% of each contact opening. A voltage of 2.1 volts or greater across the switch terminals shall constitute a contact lmissll (failure to properly close the circuit). A voltage drop of less than 90% of the open-circuit voltage shall constitute a contact %tickt1 (fa

17、ilure to properly open the circuit). The monitoring device shall either record the number of contact closures at which %ticks“ and/or “misses“ occur, or discontinue the test when “sticks1f and/or “misses“ occur. 3. PROCEDURE Each pair of switch contacts shall be operated for the number of cycles and

18、 at the rate of actuation specified in the detail specification with the required test load applied. The test shall be performed under the environmental conditions specified in the detail specificaticn. EIA 448-4 0 M 3234b00 OOb9097 L M RS-448-4 Addendum 4 Page 2 4. SUMMARY The following details sha

19、ll be specified in the detail specification: 4.1 4.2 The rate of actuation. The number of cycles of operation. 4.3 The number of allowable contact tlrnissesll. 4.4 The number of allowable contact %ticks“. 4.5 The environmental conditions. NOTE: In actual applications, electronic logic circuits may u

20、tilize different voltages, currents, and/or interface signal voltages, and should be care- fully analysed to determine the suitability of this logic level endurance test method. I ,- qc 6 e a EIA 448-4 80 m 3234600 00b9098 3 = RS-448-4 Addendum 4 Page 1 METHOD 18 LOW LEVEL ENDURANCE 1. PURPOSE The L

21、ow Level Endurance Test is a measure of the ability of a switch to control electrical loads which have insuffiecent energy to cause any physical change in the switch contacts. 2. TEST CONDITIONS Each pair of switch contacts shall be tested at 30 mV maximum, 10 mA maximum resistive load. During each

22、closure of the contacts, the voltage drop across the switch terminals shall be monitored for a duration of no less than 50% of each contact static closure. The switch contacts need not be monitored until 10 milliseconds after the initial contact closure to exclude any contact bounce. During each ope

23、ning of the contacts, the voltage drop across the switch terminals shall be monitored for a duration of no less than 50% of each contact opening. A voltage drop of 50% of the open circuit voltage or greater across the switch terminals shall constitute a contact “miss“ (failure to properly close the

24、circuit). A voltage drop of less than 90% of the open circuit voltage shall constitute a contact “stick“ (failure to properly open the circuit). The monitoring device shall either record the number of contact closures at which “sticks“ and/or “misses“ occur, or discontinue the test when %ticks11 and

25、/or “misses“ occur. 3. PROCEDURE Each pair of switch contacts shall be operated for the number of cycles and at the rate of actuation specified in the detail specification with the required test load applied. The test shall be performed under the environmental conditions specified in the detail spec

26、ification. RS-448-4 Addendum 4 Page 2 4. SUMMARY The foltowing details shall be specified in the detail specification: 4.1 4.2 The rate of actuation. The number of cycles of operation. 4.3 The number of allowable contact ttmissestt. 4.4 The number of allowable contact %tickstt. 4.5 The environmental conditions. NOTE: Because applications vary, they should be carefully analysed to determine the suitability of this low level endurance test method. .

展开阅读全文
相关资源
猜你喜欢
  • STAS 9844 2-1975 TEXTILES Quantitative analysis of binary mixtures of cotton fibres and cellulose base man made fibres《纺织品 棉纤维和纤维素基地人造纤维二元混合物的定量分析 》.pdf STAS 9844 2-1975 TEXTILES Quantitative analysis of binary mixtures of cotton fibres and cellulose base man made fibres《纺织品 棉纤维和纤维素基地人造纤维二元混合物的定量分析 》.pdf
  • STAS 9844 20-1982 TEXTILES Quantitative chemical analysis of tehrnary mixtures of wool with silk fibres and triacetate《纺织品 带丝绸纤维和三醋酸纤维的羊毛三元混合物的定量化学分析 》.pdf STAS 9844 20-1982 TEXTILES Quantitative chemical analysis of tehrnary mixtures of wool with silk fibres and triacetate《纺织品 带丝绸纤维和三醋酸纤维的羊毛三元混合物的定量化学分析 》.pdf
  • STAS 9844 21-1982 TEXTILES Quantitative chemical analysis of ternary mixtures of wool with polyester and polypropylene fibres《织物 羊毛、聚酯和聚丙烯纤维三元混合物定量化学分析》.pdf STAS 9844 21-1982 TEXTILES Quantitative chemical analysis of ternary mixtures of wool with polyester and polypropylene fibres《织物 羊毛、聚酯和聚丙烯纤维三元混合物定量化学分析》.pdf
  • STAS 9844 22-1982 TEXTILES analyse chimique quantitative des melanges ternaires《织物 混纺织物定量化学分析》.pdf STAS 9844 22-1982 TEXTILES analyse chimique quantitative des melanges ternaires《织物 混纺织物定量化学分析》.pdf
  • STAS 9844 23-1983 TEXTTLES Quantitative chemical analysis of ternary mixtures of wool with polyester and cellulosce fibrcs《织物 有聚酯和纤维素纤维的羊毛二元混合物的定量化学分析 》.pdf STAS 9844 23-1983 TEXTTLES Quantitative chemical analysis of ternary mixtures of wool with polyester and cellulosce fibrcs《织物 有聚酯和纤维素纤维的羊毛二元混合物的定量化学分析 》.pdf
  • STAS 9844 24-1983 TEXTILES Quantitative ehcmical analysis of ther- nary mixtures of wool with acrylic and linen fibrcs《纺织品 带有丙烯酸和亚麻纤维的羊毛三组分混合物的定量化学分析 》.pdf STAS 9844 24-1983 TEXTILES Quantitative ehcmical analysis of ther- nary mixtures of wool with acrylic and linen fibrcs《纺织品 带有丙烯酸和亚麻纤维的羊毛三组分混合物的定量化学分析 》.pdf
  • STAS 9844 25-1984 TEXTILES Quantitative chemical analysis of wool relon melana and regencrated cellulose fibres《纺织品 羊毛瑞龙梅莱纳和再生纤维素纤维的化学定量分析 》.pdf STAS 9844 25-1984 TEXTILES Quantitative chemical analysis of wool relon melana and regencrated cellulose fibres《纺织品 羊毛瑞龙梅莱纳和再生纤维素纤维的化学定量分析 》.pdf
  • STAS 9844 26-1985 Texliles QUANTITATIVE CHEMICAL ANAL YSIS OF QUATERNAR BLENDS OF WOOL POLYA- MIDE POLYESTER AND CELLULOSI C FIBRES《纺织品 羊毛,波利亚酰胺,聚酯和纤维素纤维四元混合物的定量化学分析 》.pdf STAS 9844 26-1985 Texliles QUANTITATIVE CHEMICAL ANAL YSIS OF QUATERNAR BLENDS OF WOOL POLYA- MIDE POLYESTER AND CELLULOSI C FIBRES《纺织品 羊毛,波利亚酰胺,聚酯和纤维素纤维四元混合物的定量化学分析 》.pdf
  • STAS 9844 3-1975 TEXTILES Quantitative chemical analysis of binary mixtures of acetate fi- bres with wool silk or cotton fibres《纺织品 带羊毛,丝绸或棉纤维的醋酸纤维二元混合物的定量化学分析》.pdf STAS 9844 3-1975 TEXTILES Quantitative chemical analysis of binary mixtures of acetate fi- bres with wool silk or cotton fibres《纺织品 带羊毛,丝绸或棉纤维的醋酸纤维二元混合物的定量化学分析》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1