EIA ECA-364-18B-2007 TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets.pdf

上传人:feelhesitate105 文档编号:705007 上传时间:2019-01-03 格式:PDF 页数:10 大小:63.61KB
下载 相关 举报
EIA ECA-364-18B-2007 TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets.pdf_第1页
第1页 / 共10页
EIA ECA-364-18B-2007 TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets.pdf_第2页
第2页 / 共10页
EIA ECA-364-18B-2007 TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets.pdf_第3页
第3页 / 共10页
EIA ECA-364-18B-2007 TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets.pdf_第4页
第4页 / 共10页
EIA ECA-364-18B-2007 TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、 EIA STANDARD TP-18B Visual and Dimensional Inspection Test Procedure for Electrical Connectors and Sockets EIA/ECA-364-18B (Revision of EIA-364-18A) February 2007 ANSI/EIA-364-18B-2007(R2012) Approved: February 12, 2007 Reaffirmed: December 18, 2012 EIA/ECA-364-18B NOTICE EIA Engineering Standards

2、and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his par

3、ticular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary u

4、se by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any

5、patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid compar

6、ison between the EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices

7、and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5109 formulated under the cognizance of the CE-2.0 National Connector Standards Committee and reaffirmed per Standards Proposal No. 5252.03). Published by Electronic Components Industry Associat

8、ion 2012 Engineering Department 2214 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a li

9、cense agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) i Clause 1 CONTENTS Introduction .Page11.1 Scope . 11.2 Object 12 Test resources . 12.1 Test equipment 13 Test specimen 23.1 Description

10、 23.2 Preparation 24 Test procedure . 24.1 Visual inspection . 24.2 Dimensional inspection . 25 Details to be specified . 26 Test documentation . 3ii (This page left blank) EIA/ECA-364-18B Page 1 TEST PROCEDURE No. 18B VISUAL AND DIMENSIONAL INSPECTION TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SO

11、CKETS (From EIA Standards Proposal No. 5109, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and previously published in EIA-364-18A.) 1 Introduction 1.1 Scope This standard establishes guidelines for visual and dimensional inspection of electrical connectors an

12、d sockets prior to, during, and after other test procedures. 1.2 Object The object of this test procedure is to detail standard methods for visual examination and dimensional inspection of test specimens in order to determine if the test specimens exhibit obvious defects that would affect test resul

13、ts or if a test has exposed obvious physical defects. It is not intended to substitute for full first article inspections, process capability studies and the requirements specified in the referencing document. 2 Test resources 2.1 Equipment 2.1.1 Visual examination shall be performed by the unaided

14、eye, corrected to normal vision. The use of magnification, polarized light, or other indications are not permitted, unless otherwise specified in the referencing document. 2.1.2 When specified, dimensional inspection shall be performed using suitable measuring tools and measuring equipment having an

15、 accuracy of at least one-third the tolerance for the variable to be measured. EIA/ECA-364-18B Page 2 3 Test specimen 3.1 Description A test specimen shall consist of a plug, a receptacle, or a mated plug and receptacle, or socket as specified in the referencing document. 3.2 Preparation The test sp

16、ecimen shall be examined as is. No additional preparation shall be performed, unless otherwise specified in the referencing document. 4 Test procedure 4.1 Visual examination 4.1.1 The initial examination is generally performed as a first step in a test program. It is intended to establish the genera

17、l condition of the lot of test specimens. Representative samples from the lots of specimens shall be randomly selected for the initial examination. If any part of the examination compromised the specimen, it shall not be used in subsequent tests. 4.1.2 Visual inspection such as workmanship, marking,

18、 finish, etc. shall be as specified in the referencing document. 4.2 Dimensional inspection When specified dimensional inspection shall be performed. Representative samples from the lots of specimens shall be randomly selected for the dimensional inspection. When required, a drawing shall be include

19、d in the referencing document and the dimensions to be inspected shall be indicated. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Number of specimens to be tested 5.2 Applicable standards and drawings 5.3 Special inspection conditions 5.4 Specif

20、ic visual workmanship, finish and marking requirements that need to be inspected EIA/ECA-364-18B Page 3 6 Test documentation Documentation shall contain the details specified in clause 5, with any exceptions, and the following: 6.1 Title of test 6.2 Specimen description, including fixturing if appli

21、cable 6.3 Test equipment used, and date of last and next calibration 6.4 Values and observations 6.5 Name of operator and date of test ECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill

22、in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA Standards & Technology Department 2214 Rock Hill Rd., Suite 170 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgenc

23、y of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommended Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLY Responsible Committee: Chairman: Date comments forwarded to Committee Chairman: Electronic Components Industry Association 2214 Rock Hill Road, Suite 170 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.eciaonline.org

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1