EIA RS-186-2E-1978 STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS METHOD 2 MOISTURE RESISTANCE (CYCLING).pdf

上传人:wealthynice100 文档编号:705036 上传时间:2019-01-03 格式:PDF 页数:5 大小:257.32KB
下载 相关 举报
EIA RS-186-2E-1978 STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS METHOD 2 MOISTURE RESISTANCE (CYCLING).pdf_第1页
第1页 / 共5页
EIA RS-186-2E-1978 STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS METHOD 2 MOISTURE RESISTANCE (CYCLING).pdf_第2页
第2页 / 共5页
EIA RS-186-2E-1978 STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS METHOD 2 MOISTURE RESISTANCE (CYCLING).pdf_第3页
第3页 / 共5页
EIA RS-186-2E-1978 STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS METHOD 2 MOISTURE RESISTANCE (CYCLING).pdf_第4页
第4页 / 共5页
EIA RS-186-2E-1978 STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS METHOD 2 MOISTURE RESISTANCE (CYCLING).pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、f EIA 18b-2E 78 W 3234b00 0028582 L W -. .- L, 3 a w a I ANSI/EIA RS-186-E-78 Approved October 27,1978 EIA STANDARD I (o 00 VI a STANDARD TEST METHODS FOR PASSIVE ELECTRONIC COMPONENT BARTS i RSm186.2E EIA 186-2E 78 m 3234600 0028586 9 m RS-186-2E Page 3 e 2.6 2.7 3, 3.1 3.2 3.3 3.4 3.5 3.6 Controll

2、ed Conditions - In order to insure the temperature and humidity are controlled within the Emits of the specification the instrumentation accuracy should be I1“C on temperature and 41% RH on moisture. The water utilized to produce the atmosphere should be conditioned bj an agpropriate method to assur

3、e consistently pure water with a pH value between 6.0 and 7.2 at 23 C (73 P). Final Measurements (to be taken per Paragraph 2.7.1 unless otherwise specified). 2.7.1 2.7.2 2.7.3 After Humidity - After the final cycle measurements shall be made within a period of 1 to 2 hours after removal from the hu

4、midity chamber. During the final measurements, the specimens shall not be subjected to any means of artificial drying. At High Humidity - If measurements at high humidity are specified in the individual specifica- tion, upon completion of Step 6 (Figure 1) of the final cycle, the specimens shall be

5、maintained at a temperature of 25 +2“C(77 k3.6“F) and a relative humidity of 90 to 95% for a period of 1% to 3% hours, after which the measurements specified shall be made in the chamber. After Drying-Period - If measurements after a drying period are specified then following Step 6 of the final cyc

6、le the specimens shall be conditioned at a temperature of 25 +2“C(77 k3.6“F) and a relative humidity of 50 +5% for a period of twenty-four hours, after which the measure- ments specified in the individual specification shall be made. SUMMARY The following details shall be specified in the individual

7、 specification: Mounting, if additional mounting requirements are necessary. Initial measurements (2.2). Polarization and load. 3.3.1 3.3.2 Exposure duration, number of cycles (2.5) if other than 10 cycles. Details of any low-temperature or vibration subcycling, if applicable (2.3). Final measurements (2.7). Magnitude and points of application of polarizing voltage, if applicable (2.4). Magnitude of loading voltage, if applicable (2.4).

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 130200 A3-1998 Sectional specification Fixed tantalum capacitors with solid or non-solid electrolyte Amendment A3 German version EN 130200 A3 1998《分规范 带固体或非固体电解质的固定式钽电容器 修改A.pdf DIN EN 130200 A3-1998 Sectional specification Fixed tantalum capacitors with solid or non-solid electrolyte Amendment A3 German version EN 130200 A3 1998《分规范 带固体或非固体电解质的固定式钽电容器 修改A.pdf
  • DIN EN 130200-1993 Sectional specification fixed tantalum capacitors with solid or non-solid electrolyte German version EN 130200 1993《分规范 固体或非固体电解质的钽固定电容器》.pdf DIN EN 130200-1993 Sectional specification fixed tantalum capacitors with solid or non-solid electrolyte German version EN 130200 1993《分规范 固体或非固体电解质的钽固定电容器》.pdf
  • DIN EN 130201 A2-1999 Blank detail specification Fixed tantalum capacitors with solid electrolyte porous anode Amendment A2 German version EN 130201 1993 A2 1998《空白详细规范 带固体电解质和烧结气孔.pdf DIN EN 130201 A2-1999 Blank detail specification Fixed tantalum capacitors with solid electrolyte porous anode Amendment A2 German version EN 130201 1993 A2 1998《空白详细规范 带固体电解质和烧结气孔.pdf
  • DIN EN 130201-1993 Blank detail specification fixed tantalum capacitors with solid electrolyte porous anode (sub-family 3) German version EN 130201 1993《空白详细规范 带固体电解质和多孔阳极的固定式钽电容器》.pdf DIN EN 130201-1993 Blank detail specification fixed tantalum capacitors with solid electrolyte porous anode (sub-family 3) German version EN 130201 1993《空白详细规范 带固体电解质和多孔阳极的固定式钽电容器》.pdf
  • DIN EN 130202-1999 Blank detail specification Fixed tantalum capacitors with non-solid electrolyte porous anode (sub-family 2) German version EN 130202 1998《空白详细规范 带非固体电解质和烧结多孔阳极的固.pdf DIN EN 130202-1999 Blank detail specification Fixed tantalum capacitors with non-solid electrolyte porous anode (sub-family 2) German version EN 130202 1998《空白详细规范 带非固体电解质和烧结多孔阳极的固.pdf
  • DIN EN 130502-1999 Blank detail specification - Fixed metallized polycarbonate film dielectric capacitors for direct current - Assessment level EZ German version EN 130502 1998《空白详.pdf DIN EN 130502-1999 Blank detail specification - Fixed metallized polycarbonate film dielectric capacitors for direct current - Assessment level EZ German version EN 130502 1998《空白详.pdf
  • DIN EN 131700-1998 Sectional specification Fixed capacitors for direct current with electrodes of thin metal foils and a polycarbonate film dielectric German version EN 131700 1997.pdf DIN EN 131700-1998 Sectional specification Fixed capacitors for direct current with electrodes of thin metal foils and a polycarbonate film dielectric German version EN 131700 1997.pdf
  • DIN EN 131701-1998 Blank detail specification - Fixed capacitors for direct current with electrodes of thin metal foils and a polycarbonate film dielectric - Assessment level E Ger.pdf DIN EN 131701-1998 Blank detail specification - Fixed capacitors for direct current with electrodes of thin metal foils and a polycarbonate film dielectric - Assessment level E Ger.pdf
  • DIN EN 131702-1998 Blank detail specification - Fixed capacitors for direct current with electrodes of thin metal foils and a polycarbonate film dielectric - Assessment level EZ Ge.pdf DIN EN 131702-1998 Blank detail specification - Fixed capacitors for direct current with electrodes of thin metal foils and a polycarbonate film dielectric - Assessment level EZ Ge.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1