EN 1090-5-2017 en Execution of steel structures and aluminium structures - Part 5 Technical requirements for cold-formed structural aluminium elements and cold-formed structures fo.pdf

上传人:medalangle361 文档编号:705547 上传时间:2019-01-03 格式:PDF 页数:66 大小:2.92MB
下载 相关 举报
EN 1090-5-2017 en Execution of steel structures and aluminium structures - Part 5 Technical requirements for cold-formed structural aluminium elements and cold-formed structures fo.pdf_第1页
第1页 / 共66页
EN 1090-5-2017 en Execution of steel structures and aluminium structures - Part 5 Technical requirements for cold-formed structural aluminium elements and cold-formed structures fo.pdf_第2页
第2页 / 共66页
EN 1090-5-2017 en Execution of steel structures and aluminium structures - Part 5 Technical requirements for cold-formed structural aluminium elements and cold-formed structures fo.pdf_第3页
第3页 / 共66页
EN 1090-5-2017 en Execution of steel structures and aluminium structures - Part 5 Technical requirements for cold-formed structural aluminium elements and cold-formed structures fo.pdf_第4页
第4页 / 共66页
EN 1090-5-2017 en Execution of steel structures and aluminium structures - Part 5 Technical requirements for cold-formed structural aluminium elements and cold-formed structures fo.pdf_第5页
第5页 / 共66页
点击查看更多>>
资源描述

1、BS EN 1090-5:2017Execution of steel structures and aluminium structuresPart 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applicationsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:

2、06BS EN 1090-5:2017 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1090-5:2017. The UK participation in its preparation was entrusted to TechnicalCommittee B/525/9, Structural use of aluminium.A list of organizations represented on this committee can be obtaine

3、d on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 87844 2 ICS 91.080.13; 91.080.17 Comp

4、liance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2017.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 1090-5:2017EUROPEAN STA

5、NDARD NORME EUROPENNE EUROPISCHE NORM EN 1090-5 March 2017 ICS 91.080.13; 91.080.17 English Version Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall appli

6、cations Excution des structures en acier et des structures en aluminium - Partie 5 : Exigences techniques pour lments en aluminium forms froid et structures formes froid pour applications en toiture, plafond, paroi verticale et plancher Ausfhrung von Stahltragwerken und Aluminiumtragwerken - Teil 5:

7、 Technische Anforderungen an tragende, kaltgeformte Bauelemente aus Aluminium und tragende, kaltgeformte Bauteile fr Dach-, Decken-, Boden- und Wandanwendungen This European Standard was approved by CEN on 6 February 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations whi

8、ch stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This Eu

9、ropean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members

10、are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,

11、Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any

12、 form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1090-5:2017 EBS EN 1090-5:2017EN 1090-5:2017 (E) 2 Contents Page European foreword 6 1 Scope . 7 2 Normative references . 8 3 Terms, definitions, symbols and abbreviations 9 3.1 Terms, definitions 9 3.2 Symbols and abbre

13、viations . 11 4 Specifications and documentation 12 4.1 Execution Specification . 12 4.1.1 General 12 4.1.2 Execution classes . 13 4.1.3 Layout drawings 13 4.1.4 Geometrical tolerances . 14 4.2 Installers documentation 14 4.2.1 General 14 4.2.2 Quality documentation . 14 4.2.3 Safety of the erection

14、 works 15 4.3 Detailed traceability documentation . 15 4.4 Execution documentation 15 5 Constituent products . 15 5.1 General 15 5.2 Identification, inspection documents and traceability . 15 5.3 Materials . 16 5.4 Thickness tolerances . 17 5.5 Minimum nominal sheet thicknesses 17 5.5.1 Profiled she

15、ets 17 5.5.2 Linear structural elements 17 5.6 Geometrical tolerances . 17 5.7 Mechanical fasteners . 17 5.7.1 General 17 5.7.2 Materials . 18 5.7.3 Verification of suitability 18 5.8 Accessories 18 5.9 Surface protection. 18 5.10 External fire performance for roofing elements 18 5.10.1 Products dee

16、med to satisfy the requirements for external fire performance 18 5.10.2 Products classified without the need for further testing (CWFT option) . 19 5.10.3 Other products . 19 5.11 Reaction to fire . 19 5.12 Resistance to fire . 19 5.13 Release of dangerous substances 19 5.14 Lightning protection 19

17、6 Manufacturing 19 6.1 General 19 6.2 Identification 19 6.3 Cold forming 19 BS EN 1090-5:2017EN 1090-5:2017 (E) 3 6.4 Cutting 20 6.5 Punching . 20 7 Welding at the construction site 20 8 Mechanical Fastening . 20 8.1 General 20 8.2 Use of self-tapping and self-drilling screws . 21 8.3 Use of blind r

18、ivets 22 8.4 Attachment of cold formed structural elements to the supporting member. 22 8.4.1 Types of connections and attachments 22 8.4.2 Attachment of profiled sheets to the supporting member transverse to the direction of span 22 8.4.3 Attachment of profiled sheets to the supporting member paral

19、lel to the direction of span . 24 8.4.4 Supporting member made of metal 24 8.4.5 Supporting member made of timber or other wood-based materials . 24 8.4.6 Supporting member made of concrete or masonry 25 8.5 Connecting profiled sheets . 25 8.6 Edge and field spacings of fasteners for structural elem

20、ents 26 8.6.1 General 26 8.6.2 Edge spacings of webs of trapezoidal sheeting and liner tray profiles 26 9 Erection . 26 9.1 General 26 9.2 Site conditions 26 9.3 Training / instruction of installation personnel 27 9.4 Inspection of preceding works . 27 9.5 Layout drawing . 27 9.6 Tools required 27 9

21、.7 Safety on site 27 9.8 Inspection of packaging and contents 28 9.9 Storage . 28 9.10 Damaged structural elements and connecting devices . 28 9.11 Unloading, lifting gear / slings / straps . 28 9.12 Laying . 28 9.13 Direction of lay of structural aluminium components . 29 9.14 Maintaining the cover

22、 width / adherence to tolerances . 29 9.15 Condition after installation (swarf from drilling, fouling of surface, protective film wrap) 29 9.16 Inspection after installation 29 9.17 Diaphragms and moment-resisting connections in the envelope . 29 9.18 Protection against lightning 30 10 Surface prote

23、ction . 30 10.1 Corrosion protection 30 10.2 Cleaning and maintenance . 30 11 Geometrical tolerances 31 11.1 General 31 11.2 Tolerance types 31 11.3 Essential tolerances 32 11.3.1 General 32 11.3.2 Manufacturing tolerances. 32 11.3.3 Erection tolerances . 32 11.4 Functional tolerances . 32 BS EN 109

24、0-5:2017EN 1090-5:2017 (E) 4 11.4.1 General 32 11.4.2 Tabulated values . 32 12 Inspection, testing and correction 32 12.1 General 32 12.2 Structural elements 33 12.2.1 General 33 12.2.2 Non-conforming products 33 12.3 Manufacturing: geometrical dimensions of manufactured structural elements . 33 12.

25、3.1 General 33 12.3.2 Profiled sheets 33 12.4 Welding at the construction site 34 12.5 Inspection of fastening 34 12.5.1 Self-tapping and self-drilling screws 34 12.5.2 Blind rivets 34 Annex A (normative) Basic requirements for profiled sheeting . 35 A.1 General 35 A.2 Supporting members . 35 A.3 Ed

26、ges of laying area 35 A.3.1 Longitudinal edge stiffeners . 35 A.3.2 Weakening of the cross section 36 A.3.3 Avoidance of ice damming . 36 A.4 Building physics requirements 37 A.4.1 General 37 A.4.2 Water permeability 37 A.4.3 Thermal insulation . 37 A.4.4 Avoidance of condensation 37 A.4.4.1 General

27、 37 A.4.4.2 Measures against convection 37 A.4.5 Airborne sound insulation . 38 A.4.6 Sound absorption 38 A.4.7 Protection against lightning 38 A.5 Roof drainage . 38 Annex B (normative) Additional design requirements for profiled sheeting 40 B.1 General 40 B.2 Serviceability 40 B.3 Dimensions, widt

28、hs of supports 40 B.3.1 General 40 B.3.2 Supporting members made of metal (steel / aluminium) 41 B.3.3 Supporting members made of timber 41 B.3.4 Supports made of concrete or masonry 41 BS EN 1090-5:2017EN 1090-5:2017 (E) 5 B.3.5 Shear forces / fixed points 43 B.4 Eccentric attachments 43 B.5 Stiffe

29、ning of liner trays 44 B.6 Walkability . 45 B.6.1 Walkability during installation 45 B.6.2 Walkability and access after installation 45 B.6.3 Test “Walkability” 45 B.7 Rotational restraint 47 B.8 Stressed skin design (diaphragms) . 47 B.9 Cantilevers . 47 B.10 Openings in laying areas . 48 Annex C (

30、informative) Documentation . 51 Annex D (normative) Geometrical tolerances 52 D.1 General 52 D.2 Essential and functional manufacturing tolerances Cold formed profiled sheets 52 Annex E (normative) Galvanic corrosion . 55 Annex F (normative) Additional information. 56 F.1 List of required additional

31、 information 56 F.2 List of additional information if not otherwise specified . 56 Bibliography 58 BS EN 1090-5:2017EN 1090-5:2017 (E) 6 European foreword This document (EN 1090-5:2017) has been prepared by Technical Committee CEN/TC 135 “Execution of steel structures and aluminium structures”, the

32、secretariat of which is held by SN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2017, and conflicting national standards shall be withdrawn at the latest by September 2017. Attention

33、 is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document is part of the EN 1090 series, which comprises the following parts: EN 1090-1, Execution of stee

34、l structures and aluminium structures - Part 1: Assessment and verification of constancy of performance for structural components EN 1090-2, Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures EN 1090-3, Execution of steel structures and alumi

35、nium structures - Part 3: Technical requirements for aluminium structures EN 1090-4, Execution of steel structures and aluminium structures - Part 4: Technical requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor and wall applications EN 1090-5,

36、Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications According to the CEN-CENELEC Internal Regulations, the national standards organizations of t

37、he following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Nether

38、lands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1090-5:2017EN 1090-5:2017 (E) 7 1 Scope This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed stru

39、ctural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.

40、 Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part. Welded sections are excluded from this part and a

41、re covered by EN 1090-3 except seal welding in low-stress areas. This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments

42、 of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements. A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case,

43、 EN 1090-4 and this document apply. Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE The structures covered in this standard can be for

44、 example single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements; single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or bo

45、th consist of structural elements; or suspended ceilings for interior fitting. BS EN 1090-5:2017EN 1090-5:2017 (E) 8 Figure 1 Examples of profiled sheets 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its app

46、lication. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 508-2, Roofing products from metal sheet Specification for self-supporting products of steel, aluminium or stainless steel shee

47、t Part 2: Aluminium EN 1090-1, Execution of steel structures and aluminium structures Part 1: Requirements for conformity assessment of structural elements EN 1090-3, Execution of steel structures and aluminium structures Part 3: Technical requirements for aluminium structures CEN/TS 1187, Test meth

48、ods for external fire exposure to roofs EN 1995-1 (all parts), Eurocode 5: Design of timber structures Part 1-1: General Common rules and rules for buildings EN 1999-1-1, Eurocode 9: Design of aluminium structures Part 1-1: General structural rules EN 1999-1-4, Eurocode 9 Design of aluminium structu

49、res Part 1-4: Cold-formed structural sheeting EN 10204, Metallic products Types of inspection documents BS EN 1090-5:2017EN 1090-5:2017 (E) 9 EN 13501-5, Fire classification of construction products and building elements Part 5: Classification using data from external fire exposure to roofs tests EN 62305-3:2011, Protection against lightning Part 3: Physical damage to structures and life hazard (IEC 62305-3:2010) EN ISO 376, Metallic materials Calibration of force-proving instruments used for the verification of uniaxial test

展开阅读全文
相关资源
猜你喜欢
  • BS PD ISO TS 28560-4-2014 Information and documentation RFID in libraries Encoding of data elements based on rules from ISO IEC 15962 in an RFID tag with partitioned memory《信息与文献 图书馆中应用的无线射频识别技术.pdf BS PD ISO TS 28560-4-2014 Information and documentation RFID in libraries Encoding of data elements based on rules from ISO IEC 15962 in an RFID tag with partitioned memory《信息与文献 图书馆中应用的无线射频识别技术.pdf
  • BS S 150-1975 Specification for chromium-molybdenum-vanadium-niobium heat-resisting steel billets bars forgings and parts (930-1080 MPa) (Cr 10 5 Mo 0 6 V 0 2 Nb 0 3)《铬-钼-钒-铌-耐热钢坯、棒材、锻件及零件规范(930-.pdf BS S 150-1975 Specification for chromium-molybdenum-vanadium-niobium heat-resisting steel billets bars forgings and parts (930-1080 MPa) (Cr 10 5 Mo 0 6 V 0 2 Nb 0 3)《铬-钼-钒-铌-耐热钢坯、棒材、锻件及零件规范(930-.pdf
  • BS PD ISO IEC TR 20000-12-2016 Information technology Service management Guidance on the relationship between ISO IEC 20000-1 2011 and service management frameworks CMMI-SVC 《信息技术 .pdf BS PD ISO IEC TR 20000-12-2016 Information technology Service management Guidance on the relationship between ISO IEC 20000-1 2011 and service management frameworks CMMI-SVC 《信息技术 .pdf
  • BS PD ISO IEC TR 20007-2014 Information technology Cultural and linguistic interoperability Definitions and relationship between symbols icons animated icons pictograms characters .pdf BS PD ISO IEC TR 20007-2014 Information technology Cultural and linguistic interoperability Definitions and relationship between symbols icons animated icons pictograms characters .pdf
  • BS PD ISO IEC TR 29110-5-1-3-2017 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Software engineering Management and engineering guide Generic p.pdf BS PD ISO IEC TR 29110-5-1-3-2017 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Software engineering Management and engineering guide Generic p.pdf
  • BS PD ISO IEC TR 29110-5-6-1-2015 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Systems engineering Management and engineering guide Generic pr.pdf BS PD ISO IEC TR 29110-5-6-1-2015 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Systems engineering Management and engineering guide Generic pr.pdf
  • BS PD ISO IEC TR 29110-5-6-2-2014 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Systems engineering Management and engineering guide Generic pr.pdf BS PD ISO IEC TR 29110-5-6-2-2014 Systems and software engineering Lifecycle profiles for Very Small Entities (VSEs) Systems engineering Management and engineering guide Generic pr.pdf
  • BS PD ISO IEC TS 17021-5-2014 Conformity assessment Requirements for bodies providing audit and certification of management systems Competence requirements for auditing and certifi.pdf BS PD ISO IEC TS 17021-5-2014 Conformity assessment Requirements for bodies providing audit and certification of management systems Competence requirements for auditing and certifi.pdf
  • BS PD ISO IEC TS 17021-6-2014 Conformity assessment Requirements for bodies providing audit and certification of management systems Competence requirements for auditing and certifi.pdf BS PD ISO IEC TS 17021-6-2014 Conformity assessment Requirements for bodies providing audit and certification of management systems Competence requirements for auditing and certifi.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1