EN 1143-1-2012 en Secure storage units - Requirements classification and methods of test for resistance to burglary - Part 1 Safes ATM safes strongroom doors and strongroomsSecure .pdf

上传人:孙刚 文档编号:705635 上传时间:2019-01-03 格式:PDF 页数:46 大小:1.16MB
下载 相关 举报
EN 1143-1-2012 en Secure storage units - Requirements classification and methods of test for resistance to burglary - Part 1 Safes ATM safes strongroom doors and strongroomsSecure .pdf_第1页
第1页 / 共46页
EN 1143-1-2012 en Secure storage units - Requirements classification and methods of test for resistance to burglary - Part 1 Safes ATM safes strongroom doors and strongroomsSecure .pdf_第2页
第2页 / 共46页
EN 1143-1-2012 en Secure storage units - Requirements classification and methods of test for resistance to burglary - Part 1 Safes ATM safes strongroom doors and strongroomsSecure .pdf_第3页
第3页 / 共46页
EN 1143-1-2012 en Secure storage units - Requirements classification and methods of test for resistance to burglary - Part 1 Safes ATM safes strongroom doors and strongroomsSecure .pdf_第4页
第4页 / 共46页
EN 1143-1-2012 en Secure storage units - Requirements classification and methods of test for resistance to burglary - Part 1 Safes ATM safes strongroom doors and strongroomsSecure .pdf_第5页
第5页 / 共46页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 1143-1:2012Secure storage units Requirements, classificationand methods of test forresistance to burglaryPart 1: Safes, ATM safes, strongroom doorsand strongroomsBS EN 1143

2、-1:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1143-1:2012. Itsupersedes BS EN 1143-1:2005+A1:2009 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee GW/2, Secure storage of cash, valuables and data media.A li

3、st of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLim

4、ited 2012ISBN 978 0 580 76029 7ICS 13.310Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 May 2012.Amendments issued since publicationDate Text affectedBS EN 114

5、3-1:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1143-1 April 2012 ICS 13.310 Supersedes EN 1143-1:2005+A1:2009English Version Secure storage units - Requirements, classification and methods of test for resistance to burglary - Part 1: Safes, ATM safes, strongroom doors and strongrooms U

6、nits de stockage en lieux srs - Prescriptions, classification et mthodes de test pour la rsistance leffraction - Partie 1: Coffres forts, distributeurs automatiques de billets (DAB), portes fortes et chambres fortes Wertbehltnisse - Anforderungen, Klassifizierung und Methoden zur Prfung des Widersta

7、ndes gegen Einbruchdiebstahl - Teil 1: Wertschutzschrnke, Wertschutzschrnke fr Geldautomaten, Wertschutzraumtren und Wertschutzrume This European Standard was approved by CEN on 16 March 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions fo

8、r giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in thre

9、e official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bod

10、ies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and U

11、nited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1143-1:20

12、12: EBS EN 1143-1:2012EN 1143-1:2012 (E) 2 Contents Page Foreword 4Introduction . 51 Scope 62 Normative references 63 Terms and definitions . 64 Classification and requirements 84.1 Classification 84.2 General requirements 94.2.1 Safes, strongroom doors and strongrooms . 94.2.2 ATM safes . 94.2.3 Bo

13、ltwork cover plate . 94.2.4 Cable hole . 94.2.5 User instructions . 94.3 Additional requirements for EX designation 94.4 Additional requirements for GAS designation . 104.5 Additional requirements for CD designation 105 Technical documentation . 146 Test specimen 157 Tool attack test . 157.1 Princip

14、le 157.2 Testing team . 157.3 Apparatus . 167.3.1 Attack tools 167.3.2 Clock . 167.3.3 Test blocks . 167.4 Test criteria . 177.5 Testing programme . 177.5.1 Free-standing safes . 177.5.2 Built-in safes 187.5.3 Strongrooms 187.5.4 Grades I to VIII ATM safes . 187.5.5 Grade L ATM safes 197.6 Test cond

15、itions 207.7 Procedure . 217.8 Operating time measuring 227.9 Calculation of resistance values 237.10 Test record . 238 Anchoring strength test 238.1 Free-standing safes . 238.1.1 Principle 238.1.2 Loading equipment 238.1.3 Procedure . 248.1.4 Expression of test results . 258.1.5 Test criteria . 258

16、.2 ATM safes . 258.2.1 Principle 258.2.2 Loading equipment 25BS EN 1143-1:2012EN 1143-1:2012 (E) 3 8.2.3 Procedure . 258.2.4 Expression of results 278.2.5 Test criteria 279 Explosive test . 279.1 Principle 279.2 Test specimen 279.3 Explosives 279.4 Determination of explosive charge mass 289.5 Condit

17、ions for explosive attack test 289.5.1 Safes and ATM safes . 289.5.2 Strongroom doors and strongrooms 289.6 Calculation of resistance values for the post-detonation tool attack 289.7 Test record . 2910 GAS explosive test 2910.1 Principle 2910.2 Test specimen 2910.3 Gas 2910.4 Determination of gas ch

18、arge volume 3010.5 Test equipment for gas attack testing . 3010.6 Procedure for gas attack testing 3010.7 Calculation of resistance values for the post-detonation tool attack 3010.8 Test record . 3110.9 Marking . 3111 Core drilling test 3111.1 Principle 3111.2 Test specimen 3211.3 Apparatus . 3211.3

19、.1 Safes . 3211.3.2 Strongroom doors and strongrooms 3211.4 Test method . 3211.5 Calculation of resistance value 3211.6 Marking . 3312 Test report 3313 Marking . 34Annex A (normative) Attack tools . 35Bibliography 41BS EN 1143-1:2012EN 1143-1:2012 (E) 4 Foreword This document (EN 1143-1:2012) has be

20、en prepared by Technical Committee CEN/TC 263 “Secure stroage of cash, valuables and data media”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2

21、012, and conflicting national standards shall be withdrawn at the latest by October 2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent righ

22、ts. This European Standard supersedes EN 1143-1:2005+A1:2009. Compared with EN 1143-1:2005+A1:2009, the following changes were made: a) Addition of requirements and technical type testing criteria for the conduct of the additional gas test on ATM safes of resistance grades II to VIII (Table 2; Claus

23、es 4, 10 and sub-clause 12.4); b) Optimisation of the requirements and technical type testing criteria for the anchoring test on ATM safes (Table 2; 8.2) as a basis of the use of fixed and flexible ATM bases; c) Modification of the requirements for the resistance value for the post-detonation test i

24、n the conduct of the additional test with explosives (EX). The previous criterion of complete access was deleted and replaced with partial access (Tables 1 and 2 and sub-clauses 5.8e, 6.1, 7.5.4.4, 7.6.13, 7.7 and 9.5.1); d) Editorial clarifications in sub-clauses 3.12, 4.2.3 and 8.2.3.1. According

25、to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, L

26、atvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1143-1:2012EN 1143-1:2012 (E) 5 Introduction Tests are made, the results of which are used to classify the resistance to burglary.

27、 The resistance classification can also be used for designing security systems with the provision that, depending on the criminal, the conditions at the place of the crime and the availability of tools, considerably longer times are likely to occur in real burglary attacks than in a test. Manual tes

28、ts are included, whose results and repeatability is dependant on the skill of the testing team. Machine-related tests are under development and may be included when this European Standard is revised. BS EN 1143-1:2012EN 1143-1:2012 (E) 6 1 Scope This European Standard establishes the basis for testi

29、ng and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems. 2 Normati

30、ve references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) ap

31、plies. EN 1300, Secure storage units Classification for high security locks according to their resistance to unauthorized opening 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 safe storage unit which protects its contents against burglary a

32、nd when closed has at least one internal side 1 m Note 1 to entry: Strongrooms may be cast in-situ, constructed from pre-fabricated elements or a combination of both. 3.5 strongroom door door with lock(s), boltwork and frame intended for giving access to a strongroom 3.6 ATM safe safe forming part o

33、f an ATM system 3.7 ATM base integral part of an ATM system located between the ATM safe and the surface to which the safe is to be anchored BS EN 1143-1:2012EN 1143-1:2012 (E) 7 3.8 internal space part of the interior of an ATM safe which is bounded by the inside surfaces and the boltwork cover pla

34、te(s) of the door of the ATM safe body 3.9 ATM automatic teller machine means for holding and processing cash and/or valuables Note 1 to entry: For the purpose of this standard, automated teller machines, currency exchange machines, currency recycling machines and machines such as teller assist mach

35、ines are all considered types of ATM. 3.10 ATM-System assembly of sub-units which provides an ATM function and affords security to cash and/or valuables stored within the ATM safe Note 1 to entry: An example of an ATM system is shown in Figure 1. Figure 1 Example of an ATM system Note 2 to entry: Of

36、 the sub-units shown in Figure 1, the ATM mechanism and the ATM control unit are not tested according to this European Standard. 3.11 accessories installations/devices which are part of the structure or which pass through the structure of the strongroom or strongroom door(s) for ventilation or for d

37、eposit of cash and valuables Note 1 to entry: Accessories may be always open, usually open (but can be closed in case of emergency), or closed (but can be opened if necessary). 3.12 operating time time during which a tool is used attempting to create a change in the test specimen Note 1 to entry: In

38、 the context of this standard, there are also operating times considered during which no visible modifications/changes are caused to the test specimen. 3.13 resistance unit RU burglary resistance which results from one minutes use of a tool carrying the coefficient 1 and the basic value 0 BS EN 1143

39、-1:2012EN 1143-1:2012 (E) 8 3.14 resistance grade classification designation for burglary resistance 3.15 resistance value numerical value in resistance units calculated for each test 3.16 basic value BV number in resistance units allocated to a particular tool Note 1 to entry: The basic value repre

40、sents problems in obtaining, transporting, using and operating the relevant tool at the site in question, and the necessary knowledge and experience for its efficient use. 3.17 tool coefficient number in resistance units per minute allocated to a group of tools Note 1 to entry: The tool coefficient

41、represents factors such as noise, smoke, fumes and other effects, which increase the likelihood of a burglary attack being detected. 3.18 boltwork mechanism by which a closed door is held such that, until it is in the withdrawn position, the door cannot be opened 3.19 lock device able to recognize a

42、 coded input and which performs a blocking function on the boltwork or the door 3.20 relocking device system comprising blocking and detecting elements which will prevent the boltwork from being withdrawn if a burglary attack is detected Note 1 to entry: A relocking device can be part of the locking

43、 mechanism (e.g. active or live relocker) or an independent unit (e.g. passive relocker). 3.21 to close to move the door so it becomes possible to bolt it 3.22 to bolt to throw the boltwork or the bolt of the lock (if there is no boltwork) to a position where it fixes the door in closed position 3.2

44、3 to lock to block a thrown boltwork by action of a lock 4 Classification and requirements 4.1 Classification Safes are classified to a resistance grade according to Table 1. BS EN 1143-1:2012EN 1143-1:2012 (E) 9 ATM safes are classified to a resistance grade according to Table 2. Strongroom doors a

45、nd strongrooms (with or without a door) are classified to a resistance grade according to Table 3. All products shall meet general requirements (4.2) and products with EX, GAS and CD designation shall meet additional requirements (4.3, 4.4 and 4.5). 4.2 General requirements 4.2.1 Safes, strongroom d

46、oors and strongrooms There shall be no holes through the protection material other than those necessary for locks, cables or anchoring, nor for the fitting of accessories to strongroom doors and strongrooms. Cable openings in safes, strongroom doors and strongrooms (with or without a door) shall not

47、 exceed 100 mm2. Unused cable entry openings shall be obstructed or plugged by the manufacturer by a means of which cannot be removed from the outside without leaving visible traces. Free-standing safes with a mass of less than 1 000 kg shall have at least one hole by which they can be anchored. The

48、 anchoring assembly for each anchoring hole shall sustain the force given in Table 1. 4.2.2 ATM safes ATM safes shall have means for plugging unused openings. These means shall be impossible to remove from the outside without leaving visible traces. NOTE 1 Openings through the protection material for ATM functioning are permitted in ATM safes. NOTE 2 Cable entry openings in ATM safes may be larger than 100 mm2. ATM safes, including optional ATM bases, shall have a fixing capability by which they can be anchored, and which shall sustain th