EN 12094-12-2003 en Fixed firefighting systems - Components for gas extinguishing systems - Part 12 Requirements and test methods for pneumatic alarm devices《固定式消防系统 气体灭火系统的部件 第12部.pdf

上传人:medalangle361 文档编号:705832 上传时间:2019-01-03 格式:PDF 页数:26 大小:271.58KB
下载 相关 举报
EN 12094-12-2003 en Fixed firefighting systems - Components for gas extinguishing systems - Part 12 Requirements and test methods for pneumatic alarm devices《固定式消防系统 气体灭火系统的部件 第12部.pdf_第1页
第1页 / 共26页
EN 12094-12-2003 en Fixed firefighting systems - Components for gas extinguishing systems - Part 12 Requirements and test methods for pneumatic alarm devices《固定式消防系统 气体灭火系统的部件 第12部.pdf_第2页
第2页 / 共26页
EN 12094-12-2003 en Fixed firefighting systems - Components for gas extinguishing systems - Part 12 Requirements and test methods for pneumatic alarm devices《固定式消防系统 气体灭火系统的部件 第12部.pdf_第3页
第3页 / 共26页
EN 12094-12-2003 en Fixed firefighting systems - Components for gas extinguishing systems - Part 12 Requirements and test methods for pneumatic alarm devices《固定式消防系统 气体灭火系统的部件 第12部.pdf_第4页
第4页 / 共26页
EN 12094-12-2003 en Fixed firefighting systems - Components for gas extinguishing systems - Part 12 Requirements and test methods for pneumatic alarm devices《固定式消防系统 气体灭火系统的部件 第12部.pdf_第5页
第5页 / 共26页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 12094-12:2003 Fixed firefighting systems Components for gas extinguishing systems Part 12: Requirements and test methods for pneumatic alarm devices The European Standard EN 12094-12:2003 has the status of a British Standard ICS 13.220.20; 13.320 BS EN 12094-12:2003 This Briti

2、sh Standard, was published under the authority of the Standards Policy and Strategy Committee on 1 July 2003 BSI 1 July 2003 ISBN 0 580 42193 7 National foreword This British Standard is the official English language version of EN 12094-12:2003. This European Standard is the subject to transitional

3、arrangements agreed under a Commission mandate which is intended to lead to CE marking in support of the Construction Products Directive. In order to allow for any changes in national regulations, the Member States have agreed a transition period of 30 months before CE marking becomes effective. The

4、 UK participation in its preparation was entrusted by Technical Committee FSH/18, Fixed fire fighting systems, to Subcommittee FSH/18/6, Gaseous extinguishing systems, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretar

5、y. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue

6、 or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the t

7、ext; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front c

8、over, an inside front cover, the EN title page, pages 2 to 23 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN1209412 March2003

9、ICS13.220.20;13.320 Englishversion FixedfirefightingsystemsComponentsforgasextinguishing systemsPart12:Requirementsandtestmethodsfor pneumaticalarmdevices InstallationsfixesdeluttecontrelincendieElments constitutifspoursystmesdextinctiongazPartie12: Exigencesetmthodesdessaipourdispositifs pneumatiqu

10、esdalarme OrtsfesteBrandbekmpfungsanlagenBauteilefr LschanlagenmitgasfrmigenLschmittelnTeil12: AnforderungenundPrfverfahrenfrpneumatische Alarmgerte ThisEuropeanStandardwasapprovedbyCENon7November2002. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivin

11、gthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheManagementCentreortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyoth

12、erlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheManagementCentrehasthesamestatusasthe official versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Hungary,Iceland,Ireland,Italy,Luxemb

13、ourg,Malta,Netherlands,Norway,Portugal,Slovakia,Spain,Sweden,SwitzerlandandUn ited Kingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2003CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwi

14、deforCENnationalMembers. Ref.No.EN1209412:2003EEN1209412:2003(E) 2 Contents page Foreword. 3 Introduction 5 1 Scope 6 2 Normativereferences . 6 3 Termsanddefinitions. 6 4 Requirements 7 4.1 Compliance 7 4.2 Design 7 4.3 Functionatnormaltemperature 8 4.4 Functionathighandlowtemperature 8 4.5 Function

15、alreliability . 8 4.6 Operationalreliability . 8 4.7 Functionincoldandmoistatmosphere. 8 4.8 Corrosion . 8 4.9 Stresscorrosion 8 4.10 Vibration. 8 4.11 Impact. 9 4.12 Documentation 9 5 Testmethods . 9 5.1 Testconditions. . 9 5.2 Testsamplesandorderoftests. . 10 5.3 Compliance 10 5.4 Functionatnormal

16、temperature 10 5.5 Functionathighandlowtemperature 10 5.6 Functionalreliability . 11 5.7 Operationalreliability . 11 5.8 Functionincoldandmoistatmosphere. 11 5.9 Corrosion . 11 5.10 Stresscorrosion. . 12 5.11 Vibration(sinusoidal) . 12 5.12 Impact. 13 6 Marking. 15 7 Evaluationofconformity 16 7.1 Ge

17、neral . 16 7.2 Initialtypetesting 16 7.3 Factoryproductioncontrol(FPC) 17 AnnexZA (informative) ClausesofthisEuropeanStandardaddressingtheprovisionsoftheEU ConstructionProductsDirective . 20 Bibliography . 23EN1209412:2003(E) 3 Foreword Thisdocument(EN1209412:2003)hasbeenpreparedbyCEN/TC191“Fixedfir

18、efightingsystem“,thesecretariat ofwhichisheldbyBSI. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherbypublicationofanidenticaltextor byendorsement,atthelatestbySeptember2003,andconflictingnationalstandardsshallbewithdrawnatthe latestbySeptember2005. Thisdocumenthasbeenpreparedunde

19、ramandategiventoCENbytheEuropeanCommissionandtheEuropean FreeTradeAssociation,andsupportsessentialrequirementsofEUDirective(s). ForrelationshipwithEUDirective(s),seeinformativeAnnexZA,whichisanintegralpartofthisdocument. ThispartofEN12094isoneofanumberofEuropeanStandardspreparedbyCEN/TC191coveringco

20、mponents forgasextinguishingsystems. TheyareincludedinaseriesofEuropeanStandardsplannedtocover: gasextinguishingsystems(EN12094); sprinklersystems(EN12259:1999+A1andEN12845); powdersystems(EN12416); explosionprotectionsystems(EN26184); foamsystems(EN13565); hosesystems(EN671); smokeandheatcontrolsys

21、tems(EN12101); waterspraysystems 1) . ThisEuropeanStandardhasthegeneraltitle “FixedfirefightingsystemsComponentsforgasextinguishing systems“andwillconsistofthefollowingparts: Part1: Requirementsandtestmethodsforelectricalautomaticcontrolanddelaydevices Part2: Requirementsandtestmethodsfornonelectric

22、alautomaticcontrolanddelaydevices Part3: Requirementsandtestmethodsformanualtriggeringandstopdevices Part4: Requirementsandtestmethodsforhighpressurecontainervalveassembliesandtheiractuators Part5: RequirementsandtestmethodsforhighandlowpressureselectorvalvesandtheiractuatorsforCO 2 systems Part6: R

23、equirementsandtestmethodsfornonelectricaldisabledevicesforCO 2 systems 1) Underpreparation.EN1209412:2003(E) 4 Part7: RequirementsandtestmethodsfornozzlesforCO 2 systems Part8: RequirementsandtestmethodsforflexibleconnectorsforCO 2 systems Part9: Requirementsandtestmethodsforspecialfiredetectors Par

24、t10: Requirementsandtestmethodsforpressuregaugesandpressureswitches Part11: Requirementsandtestmethodsformechanicalweighingdevices Part12: Requirementsandtestmethodsforpneumaticalarmdevices Part13: Requirementsandtestmethodsforcheckvalvesandnonreturnvalves Part16: Requirementsandtestmethodsforodoriz

25、ingdevicesforCO 2 lowpressuresystems Part17: Pipehangers Part20: Requirementsandtestmethodsforthecompatibilityofcomponents AccordingtotheCEN/CENELECInternalRegulations,thenationalstandardsorganizationsofthefollowing countriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,CzechRepublic,Denma

26、rk,Finland, France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal, Slovakia,Spain,Sweden,SwitzerlandandtheUnitedKingdom.EN1209412:2003(E) 5 Introduction IthasbeenassumedinthepreparationofthisEuropeanStandardthattheexecutionofitsprovisionsisentrusted toappro

27、priatelyqualifiedandexperiencedpeople. AllpressuredatainthisEuropeanStandardaregivenasgaugepressuresinbar,unlessotherwisestated. NOTE 1bar=10 5 Nm 2 =100kPa.EN1209412:2003(E) 6 1Scope ThisEuropeanStandardspecifiesrequirementsandtestmethodsforsurfacemountedaudiblealarmdevices poweredbypneumaticenergy

28、(pneumaticalarmdevices)towarnpersonsinfloodingzonesofCO 2 ,InertGasor Halocarbongasfireextinguishingsystems. 2 Normativereferences ThisEuropeanStandardincorporatesbydatedorundatedreferences,provisionsfromotherpublications.These normativereferencesarecitedattheappropriateplacesinthetext,andthepublica

29、tionsarelistedhereafter.For datedreferences,subsequentamendmentstoorrevisionsofanyofthesepublicationsapplytothisEuropean Standardonlywhenincorporatedinitbyamendmentorrevision.Forundatedreferencesthelatesteditionofthe publicationreferredtoapplies(includingamendments). EN6006826:1995, Environmentaltes

30、tingPart2:TestsTestFc:Vibration(sinusoidal)(IEC6006826:1995+ Corrigendum1995). EN60651:1994, Soundlevelmeters(IEC60651:1993). ISO2091;WroughtaluminiumandaluminiumalloysChemicalcompositionandformsofproductsPart1: Chemicalcomposition 3 Termsanddefinitions ForthepurposesofthisEuropeanStandard,thefollow

31、ingtermsanddefinitionsapply: 3.1 Aweightedsoundlevel Soundpressure,expressedindB,whichis20timesthelogarithmtobasetenoftheratiooftheAweightedsound pressuretothereferencepressureof20Pa(20N/m 2 ).AweightingcharacteristicsaregiveninEN60651:1994 3.2 CO 2 highpressureinstallation fireextinguishinginstalla

32、tioninwhichtheCO 2 isstoredatambienttemperature.Forexample,thepressureofthe CO 2 instorageisp abs =58,6barat21C 3.3 CO 2 lowpressureinstallation fireextinguishinginstallationinwhichtheCO 2 isstoredatlowtemperature,normally19Cto21C 3.4 halocarbongas extinguishingagentthatcontainsasprimarycomponentson

33、eormoreorganiccompoundscontainingoneormore oftheelementsfluorine,chlorine,bromineoriodine 3.5 halocarbongasinstallation fireextinguishinginstallationinwhichthehalocarbongasisstoredatambienttemperatureEN1209412:2003(E) 7 3.6 inertgas nonliquefiedgasormixtureofgaseswhichextinguishthefiremainlybyreduci

34、ngtheoxygenconcentrationinthe protectedzone,e.g.Argon,NitrogenorCO 2 ormixturesofthesegases 3.7 inertgasinstallation fireextinguishinginstallationinwhichtheinertgasisstoredatambienttemperature 3.8 principalaxis linethroughthegeometricalcentreofthesoundradiationcone,perpendiculartothefrontsurfaceofth

35、eaudible alarmdevice 3.9 referencepoint pointwheretheprincipalaxisoftheaudiblealarmdeviceintersectsitsmountingsurface 4Requirements 4.1Compliance Thetestsampleshallcomplywiththedocumentation(drawings,partslists,descriptionoffunctions,operatingand installationinstructions)whenevaluatedinaccordancewit

36、h5.3. 4.2Design Componentswithpassagesinthegasflowwithfreeflowcrosssections 7mm 2 shallbepermanentlyequipped withafilter.Thefiltershallbemadeofcorrosionresistantmetal. Ifmeshfiltersareused,theunrestrictedfiltersurfaceareashallbeatleastfivetimesthesumofthegasflowareas inthecomponentandthemeshofthefil

37、tershallbebetween0,5timesand0,8timesthesmallestdimensionofany passageinthegasflow. Ifsinteredmetalfiltersareused,thesurfaceareaofthefilterinthegasflowdividedbytheporosityshallbeatleast fivetimesthesumofthegasflowareasinthecomponent. Themanufacturershallspecify: Aweightedsoundleveloverthepressurerang

38、e; pressurerange; typeofsupplygas; maximumflowrateofsupplygasinthespecifiedpressurerange; minimumoperatingtemperature:20Corlower; maximumoperatingtemperature:+50Corhigher. Wherethemanufacturerspecifiesextendedtemperatureranges,thesetemperaturesshallbeusedforthe requirementin4.4andthetestin5.5.EN1209

39、412:2003(E) 8 4.3 Functionatnormaltemperature ThecomponentsshallgenerateanAweightedsoundlevelbetween90dB(A)and120dB(A)atadistanceof1m, foratleast30min,whentestedinaccordancewith5.4. Inthistesttheflowrateshallnotexceedthevaluegivenbythemanufacturer. 4.4 Functionathighandlowtemperature Componentsshall

40、generateanAweightedsoundlevelnotmorethan15dB(A)differentfromtheirsoundlevelat normaltemperature,whentestedinaccordancewith5.5attheminimumandmaximumspecifiedoperating temperatures. Inthistesttheflowrateshallnotexceedthevaluegivenbythemanufacturer. 4.5Functional reliability ComponentsshallgenerateanAw

41、eightedsoundlevelbetween90dB(A)and120dB(A)atadistanceof1m, whentestedinaccordancewith5.6withtheminimumandmaximumspecifiedsupplypressure Inthistesttheflowrateshallnotexceedthevaluegivenbythemanufacturer. 4.6 Operationalreliability Thesoundlevelofthecomponentsshallvarynotmorethan6dB(A),whentestedfor10

42、0hinaccordancewith 5.7. 4.7 Functionincoldandmoistatmosphere ComponentsshallgenerateanAweightedsoundlevelnotmorethan15dB(A)differentfromtheirsoundlevelat normaltemperature,whentestedinaccordancewith5.8. 4.8Corrosion ComponentsshallgenerateanAweightedsoundlevelbetween90dB(A)and120dB(A)atadistanceof1m

43、,for atleast5min,whentestedinaccordancewith5.4afterbeingsubjectedtocorrosiveatmosphereinaccordance with5.9. 4.9Stress corrosion Anycopperalloypartusedinthecomponentshallnotcrack,whentestedasdescribedin5.10. 4.10Vibration ThecomponentsshallshownosignofdamageandshallgenerateanAweightedsoundlevelbetween90dB(A) and120dB(A)atadistanceof1m,foratleast5min,whentestedinaccordancewith5.4afterbeingsubjectedto vibrationinaccordancewith5.11. Duringvibrationthecomponentsshallgen