EN 12427-2000 en Industrial Commercial and Garage Doors and Gates - Air Permeability - Test Method《工业 商业用汽车库门 大门透气性的试验方法》.pdf

上传人:sofeeling205 文档编号:706283 上传时间:2019-01-03 格式:PDF 页数:10 大小:404.46KB
下载 相关 举报
EN 12427-2000 en Industrial Commercial and Garage Doors and Gates - Air Permeability - Test Method《工业 商业用汽车库门 大门透气性的试验方法》.pdf_第1页
第1页 / 共10页
EN 12427-2000 en Industrial Commercial and Garage Doors and Gates - Air Permeability - Test Method《工业 商业用汽车库门 大门透气性的试验方法》.pdf_第2页
第2页 / 共10页
EN 12427-2000 en Industrial Commercial and Garage Doors and Gates - Air Permeability - Test Method《工业 商业用汽车库门 大门透气性的试验方法》.pdf_第3页
第3页 / 共10页
EN 12427-2000 en Industrial Commercial and Garage Doors and Gates - Air Permeability - Test Method《工业 商业用汽车库门 大门透气性的试验方法》.pdf_第4页
第4页 / 共10页
EN 12427-2000 en Industrial Commercial and Garage Doors and Gates - Air Permeability - Test Method《工业 商业用汽车库门 大门透气性的试验方法》.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、STD-BSI BS EN 12427-ENGL 2000 Lb2LibbS 08753LiO 50b BRITISH STANDARD BS EN 12427:2000 Industrial, commercial and garage doors and gates - Air permeability - Test method The European Standard EN 1242F2000 has the status of a British Standard ICs 91.060.50 NO COPYING WiTHOT BSI PERMISSION EXCEPT AS PE

2、RMITTED BY COPYRIGJ LAW STD-BSI BS EN 32427-ENGL 2000 = Lb24bb9 0875343 442 BS EN 1242R2000 direction of the Sector Committee for Buiidirig and Chil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 October 2000 Amd. No. O BSI 10-2000 National fore

3、word Date Comments This British Standard is the official English language version of EN 124272000. The UK participation in its preparation was entxusted by Technical Committee B38, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B3W5, Industriai, commercial and garage doors a

4、nd gates, which has the responsibility to: - aid enquirers to understand the te*, - present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related international and European developments and promulgate

5、 them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement internationai or European publications referred to in this document may be found in the BSI Standards Catalogue under the sect

6、ion entitled “International Standards Correspondence Index“, or by using the “Find“ facility of the BSI Stan doors on lifts; doors on vehicles; armoured doors; doors mainly for the retention of animals; theatre textile curtains: horizontally moving doors less than 2,5 m wide and 6,25 m2 area, design

7、ed principally for pedestrian use; revolving doors of any size; doors outside the reach of people (such as crane gantry fences); railway barriers; barriers used solely for vehicles. Normative References This European Standard incorporates by dated or undated reference, provisions from other publicat

8、ions. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references subsequent amendments to or revi- sions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision.

9、 For undated references the latest edition of the publication re- ferred to applies. EN 12 433-1 EN 12 433-2 EN 12 426 Industrial, commercial and garage doors and gates - Terminology - Part 1 : Types of doors Industrial, commercial and garage doors and gates - Terminology - Part 2: Parts of doors In

10、dustrial, commercial and garage doors and gates - Air permeability - Classification Page 4 EN 12427:2000 prEN 13 241 : 1998 Industrial, commercial and garage doors and gates - Product standard 3 Terms and definitions For the purpose of this standard the terms and definitions in EN 12 433-1 and EN 12

11、 433-2 apply. In addition the following definitions also apply: 3.1 Air permeability: ability of a test specimen in relation to the overall area, when in closed position, to allow air flow, expressed in m3/m2 h. 3.2 Overall area: the area of the structural opening of the specimen, expressed in squar

12、e meters (m2). 4 Principle of test Application of air pressure (positive or negative) on the external or internal surface of the test specimen whilst a measurement of the airflow is made with a device according to 5 c). 5 Apparatus The basic test apparatus shall include: a) an opening to which the t

13、est specimen can be fitted, to simulate the structural open- ing of the product on site. b) device( to provide controlled air pressure, above atmospheric air pressure, to the exposed surface of the specimen. c) device) to measure the amount of airflow with an accuracy of +. 5%. It shall be Cali- bra

14、ted so as to give airflow in normal conditions (20C, 1 O1 kPa). d) device) for measuring air pressure with an accuracy of 5%. e) a means of sealing all joints of the specimen when required. NOTE The test rig should not be designed to increase the performance of the specimen. The test rig shall be pr

15、epared so that it is able to withstand the pressures applied during the test, without deflecting to an extent likely to impair jointing or to impose bending stresses. 6 Preparation of test specimen a) The test specimen shall be installed in accordance with the manufacturers standard or published ins

16、tallation instructions. b) The test specimen shall consist of parts, which in detail conform to the production level of quality. Whenever possible the test specimen should be newly made. Doors and parts in stock are to be regarded as newly made if they fully comply with the specification of the runn

17、ing production. STD=BSI BS EN l12427-ENGL 2000 lb29bb9 0875346 T24 Commercial and garage doors Industrial doors Page 5 EN 12427:2000 Width: 2 O00 mm Height: 2 O00 mm Width: 3 500 mm Height: 3 O00 mm c) The test specimen shall be clean and the surfaces dry. d) Any ventilation, drainage or “weep holes

18、“ shall be taped up or left open according to the purpose of test and this purpose and state shall be noted and recorded. In most cases, air can pass through both fixed and opening joints. Minimum dimensions of specimen see table 1. e) Table 1 - Minimum dimensions of specimen 7 Test procedure 7.1 Pr

19、eliminaries The test specimen shall be conditioned for at least 4 h within the range 10C to 30C and 25% to 75% relative humidities immediately before testing. Temperature shall be measured within reference to this standard; name of the approved laboratory, if applicable; all necessary references to

20、identify the specimen; all relevant details concerning the dimensions of the specimen, its materials, design, con- struction and manufacture and its finished surface and fittings and also its method of de- livery; drawings of details of the specimen shall be of a suitable scale; identification of th

21、e test equipment; test method; test procedures, including storage and conditioning prior to test and mounting the speci- men ready for test; test climates used; location of air leakage, if detectable; take the overall area (m) into account when to calculate the specific airflow in m3/ m2h (see 3.2);

22、 air permeability result; summary with observations; determine the classification according to EN 12 426; signature of the responsible person. STD-BSI BS EN LZi27-ENGL 2000 I Lb24bb7 08753V8 BT7 I Page 7 EN 12427:2000 Annex A (normative) Air pressure sequence for test rig -i Opening and closing oper

23、ation Stabilized pressure BS EN 12427:2000 BSI 389 Chiswick High Road London w4 4AL BSI - British Standards Institution BSI is the independent national body responsible for preparing British Stanhds. It presents the UK view on stanhds in Europe and at the international level. It is incorporated by R

24、oyal Charter. Revisions British Standars are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendmens or editions. it is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an

25、inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel 020 8996 9OoO. Fax: 020 8996 7400. BSI offers members an individual updating service called PLUS which ensure

26、s that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001. In response to orders for international standards, it is

27、BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters

28、Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel 020 8996 7111. Fax: 020 8996 7048. Subscribing members of BSI are kept up to date with standards developments and receive substantial disco

29、unts on the purchase price of stanhds. For details of these and other benefits contact Membership Administsati on Tel 020 8996 7002. Fax: 020 8996 7001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the Publications of the intedonal standardization

30、 bodies. Except as permitted under the Copynght, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or tmmmitted in any form or by any means - electronic, photocopying, recordhg or otherwise - without prior written permission from BSI. Ihis does not preclude the

31、free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. permission is granted, the terms may include royaity payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. re1 020 8996 7070.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1