1、BS EN 1253-5:2017Gullies for buildingsPart 5: Gullies with light liquids closureBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 1253-5:2017 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1253-5:2017. Itsupersedes BS EN 125

2、3-5:2003 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/505/11, Waste Fittings For Sanitary Appliances.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all t

3、he necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2017. Published by BSI Standards Limited 2017ISBN 978 0 580 90753 1ICS 91.140.80Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Stand

4、ard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2017.Amendments/Corrigenda issued since publicationDate Text affectedBS EN 1253-5:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1253-5 February 2017 ICS 91.140.80 Supersedes EN 1253-5:2003En

5、glish Version Gullies for buildings - Part 5: Gullies with light liquids closure Avaloirs et siphons pour btiments - Partie 5 : Siphons avec obturateur pour liquides lgers Ablufe fr Gebude - Teil 5: Ablufe mit Leichtflssigkeitssperren This European Standard was approved by CEN on 14 December 2016. C

6、EN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on ap

7、plication to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC

8、Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, L

9、atvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre:

10、Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1253-5:2017 EBS EN 1253-5:2017EN 1253-5:2017 (E) 2 Contents Page European foreword . 3 1 Scope 4 2 Normative references 4 3 Terms and definition

11、s . 4 4 Types 4 5 Materials . 4 6 Requirements . 5 6.1 General 5 6.2 Inflow . 5 6.3 Security height . 5 6.4 Tightness 5 6.5 Maintenance 6 6.6 Flow rates . 6 7 Test methods 7 7.1 General 7 7.2 Closing ability and tightness . 7 7.3 Security height . 7 8 Marking . 7 9 Evaluation of conformity 8 Bibliog

12、raphy 9 BS EN 1253-5:2017EN 1253-5:2017 (E) 3 European foreword This document (EN 1253-5:2017) has been prepared by Technical Committee CEN/TC 165 “Wastewater engineering”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by pub

13、lication of an identical text or by endorsement, at the latest by August 2017, and conflicting national standards shall be withdrawn at the latest by August 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be he

14、ld responsible for identifying any or all such patent rights. This document supersedes EN 1253-5:2003. This is the fifth part in EN 1253, a series of standards relating to different types of floor gullies, roof drains and access covers for drainage systems inside buildings. The EN 1253 series under

15、the main title Gullies for buildings actually consists of the following parts: Part 1: Trapped floor gullies with a depth water seal of at least 50 mm; Part 2: Roof drains and floor gullies without trap; Part 3: Evaluation of conformity; Part 4: Access covers; Part 5: Gullies with light liquids clos

16、ure. Since the latest versions of EN 1253-5 the most significant technical changes are the following: a) introduction of the new standards on trapped floor gullies with a depth of water seal of at least 50 mm (EN 1253-1) and evaluation of conformity (EN 1253-3); b) amendment of scope, classification

17、, requirements as well as methods of marking. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Form

18、er Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1253-5:2017EN 1253-5:2017 (

19、E) 4 1 Scope This European Standard specifies requirements for the design, construction, performance, application and marking as well as test methods of factory made gullies with a light liquid closure for buildings. Light liquid closures for buildings are applied to avoid uncontrolled discharge of

20、light liquids into drainage systems in case of emergency. This European Standard does not apply to installations for separation of light liquids covered by EN 858-1. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable

21、 for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1253-1:2015, Gullies for buildings - Part 1: Trapped floor gullies with a depth water seal of at least 50 mm EN 125

22、3-3, Gullies for buildings - Part 3: Evaluation of conformity 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1253-1:2015 and the following apply. 3.1 gully with a light liquid closure trapped floor gully with closure device which prevents the light l

23、iquid from entering the drainage system 3.2 light liquid closure device which automatically closes the gully outlet when a certain level of light liquid is present 3.3 light liquid liquid with a density not greater than 0,95 g/cm3which is actually or practically insoluble in water and unsaponifiable

24、 Note 1 to entry: Such liquids are, e.g. petrol, diesel fuel, fuel oil. 4 Types Type A: Gully with an integrated light liquid closure with a flow rate in accordance with Table 1 for the unlimited use in gravity drainage systems. Type B: Gully with light liquid closure which is incorporated as an acc

25、essory, with a minimum flow rate given in Table 1, which may be reduced up to 30 % for use in gravity drainage systems. 5 Materials All material in contact with the light liquid and the wastewater shall be resistant to light liquids and to wastewater. BS EN 1253-5:2017EN 1253-5:2017 (E) 5 6 Requirem

26、ents 6.1 General A gully with light liquid closure shall fulfil all requirements given in EN 1253-1, except for flow rates, and the following requirements given in 6.2 to 6.6. The manufacturer shall supply all the appropriate information concerning the use of the trapped gully with a light liquid cl

27、osure, e.g. handling, transport, temporary storage and instructions for installation, operation and maintenance. 6.2 Inflow The inflow shall be through the grating on the top of the gully. Inlets under the grating and behind the light liquid closure are not allowed. The light liquid closure shall be

28、 sufficiently protected against dust, dirt, inflow and others which could impair functioning. 6.3 Security height When the light liquid closure has closed the gully, there shall be a security distance between the sealing and the separating line between water and light liquid of 30 mm. Dimensions in

29、millimetres Key 1 grating 4 sealing level 7 static water level 2 light liquid layer 5 float 3 parting line light liquid water 6 float guiding device Figure 1 Gully with light liquid closure 6.4 Tightness When tested in accordance with 7.2, the leakage shall be less than 0,1 l/h. BS EN 1253-5:2017EN

30、1253-5:2017 (E) 6 6.5 Maintenance Closure devices shall be easily removable for servicing. 6.6 Flow rates Where a gully with a light liquid closure device is designed, the gully flow rate shall be as given in Table 1. Table 1 Minimum flow rates Nominal size of outletaFloor gullies (qgrate) DN/OD DN/

31、ID Minimum flow rate l/s Head of water h mm 32 0,4 20 30 0,4 40 0,6 40 0,6 50 0,8 50 0,8 63 0,8 75 0,8 70 0,8 75 0,8 90 0,8 100 1,4 100 1,4 110 1,4 125 2,8 125 2,8 150 4,0 160 4,0 aAll dimensions not mentioned in this table shall be tested with the next higher dimension. BS EN 1253-5:2017EN 1253-5:2

32、017 (E) 7 7 Test methods 7.1 General The gully shall, by means of the test methods in EN 1253-1, demonstrate the fulfilling the requirements given in EN 1253-1 and the following. 7.2 Closing ability and tightness After the flow rate test in accordance with EN 1253-1 add light liquid with a density c

33、orresponding to that indicated by the manufacturer 0,015 g/cm3at 12 C, slowly (0,1 l/s) into the gully, until the closure device closes, but at least up to the top of the grating. Place a container under the pipe outlet, and determine after 1 h the amount of water and light liquid in the container.

34、7.3 Security height When the closure device has closed (see 7.2), measure by suitable methods the distance between the sealing and the separating line between water and light liquid. 8 Marking Gullies with a light liquid closure device and their components shall bear the following clear and durable

35、markings, for example, cast on, by engraving, painting, stamping or labelling (including electronic recognition labelling) as indicated in Table 2: a) EN 1253-5; b) name and/or mark of the manufacturer; c) period of manufacture (coded or not); d) identification of independent certification body, whe

36、re applicable; e) identification of DN, load class and type. BS EN 1253-5:2017EN 1253-5:2017 (E) 8 Table 2 Location of marking of gullies with a light liquid closure device ItemsdGully body Grating Float device Components Package EN 12535 X XaXaXaX Manufacturers name or mark X XaX Period of manufact

37、ure X Independent certification bodybX Load class XcX DN XaX TypeeXa X aIf possible. bWhere applicable. cFor the classes H and K the marking is optional. dFurther marking may be added (e.g. for application). The marking shall be visible where possible, after the unit has been installed. eOnly for co

38、ndition as specified in Clause 4, Type B. Where the application of the marking would be detrimental to the production and/or functioning of the product, the marking shall be included on the packaging. 9 Evaluation of conformity The evaluation of conformity shall be provided as given in EN 1253-3. BS

39、 EN 1253-5:2017EN 1253-5:2017 (E) 9 Bibliography 1 EN 858-1, Separator systems for light liquids (e.g. oil and petrol) - Part 1: Principles of product design, performance and testing, marking and quality control This page deliberately left blankThis page deliberately left blankBSI is the national bo

40、dy responsible for preparing British Standards and other standards-related publications, information and services.BSI is incorporated by Royal Charter. British Standards and other standardization products are published by BSI Standards Limited.British Standards Institution (BSI)About usWe bring toge

41、ther business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions.The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process. Organi

42、zations of all sizes and across all sectors choose standards to help them achieve their goals.Information on standardsWe can provide you with the knowledge that your organization needs to succeed. Find out more about British Standards by visiting our website at or contacting our Customer Services t

43、eam or Knowledge Centre.Buying standardsYou can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at where hard copies can also be purchased. If you need international and foreign standards from other Standards

44、 Development Organizations, hard copies can be ordered from our Customer Services team.Copyright in BSI publicationsAll the content in BSI publications, including British Standards, is the property of and copyrighted by BSI or some person or entity that owns copyright in the information used (such a

45、s the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use.Save for the provisions below, you may not transfer, share or disseminate any portion of the standard to any other person. You may not adapt, distribute, commercially expl

46、oit, or publicly display the standard or any portion thereof in any manner whatsoever without BSIs prior written consent.Storing and using standardsStandards purchased in soft copy format: A British Standard purchased in soft copy format is licensed to a sole named user for personal or internal comp

47、any use only. The standard may be stored on more than 1 device provided that it is accessible by the sole named user only and that only 1 copy is accessed at any one time. A single paper copy may be printed for personal or internal company use only.Standards purchased in hard copy format: A British

48、Standard purchased in hard copy format is for personal or internal company use only. It may not be further reproduced in any format to create an additional copy. This includes scanning of the document.If you need more than 1 copy of the document, or if you wish to share the document on an internal n

49、etwork, you can save money by choosing a subscription product (see Subscriptions).Reproducing extractsFor permission to reproduce content from BSI publications contact the BSI Copyright & Licensing team.SubscriptionsOur range of subscription services are designed to make using standards easier for you. For further information on our subscription products go to British Standards Online (BSOL) youll have instant access to over 55,000 British and ado

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1