1、BSI Standards PublicationBS EN 1303:2015Building hardware Cylindersfor locks Requirements andtest methodsBS EN 1303:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1303:2015. It supersedes BS EN 1303:2005 which is withdrawn.The UK participation in its prepa

2、ration was entrusted to Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users a

3、re responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 79117 8 ICS 91.190 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the

4、Standards Policy and Strategy Committee on 30 June 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1303 June 2015 ICS 91.190 Supersedes EN 1303:2005English Version Building hardware - Cylinders for locks - Requiremen

5、ts and test methods Quincaillerie pour le btiment - Cylindres de serrures - Exigences et mthodes dessai Schlsser und Baubeschlge - Schliezylinder fr Schlsser - Anforderungen und Prfverfahren This European Standard was approved by CEN on 19 March 2015. CEN members are bound to comply with the CEN/CEN

6、ELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre

7、or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the of

8、ficial versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherland

9、s, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights o

10、f exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1303:2015 EBS EN 1303:2015Contents Page Foreword . 4 Introduction 5 1 Scope 6 2 Normative references . 6 3 Terms and definitions . 7 4 Requirements 8 4.1 General . 8 4.2 Category of use Key strength

11、. 8 4.3 Durability 8 4.4 Door mass 8 4.5 Suitability for use on fire resistant / smoke control doors . 8 4.6 Safety 8 4.7 Corrosion resistance and operation at extreme temperatures 8 4.7.1 Corrosion resistance 8 4.7.2 Operation at extreme temperatures 9 4.8 Key related security 9 4.8.1 Minimum numbe

12、r of effective differs 9 4.8.2 Minimum number of movable detainers . 9 4.8.3 Maximum number of identical steps . 9 4.8.4 Direct coding on key . 9 4.8.5 Operation of security mechanism (inter-passing) . 9 4.8.6 Torque resistance of plug/cylinder relevant to key related security . 10 4.9 Attack resist

13、ance 10 4.9.1 General . 10 4.9.2 Resistance to attack by drilling . 10 4.9.3 Resistance to attack by chisel . 11 4.9.4 Resistance to attack by twisting . 11 4.9.5 Resistance to attack by plug / cylinder extraction 11 4.9.6 Torque resistance of plug/cylinder relevant to attack resistance . 11 5 Test

14、General and test apparatus 12 5.1 General . 12 5.2 Test rigs and apparatus 13 6 Test methods procedures . 13 6.1 General . 13 6.2 Key strength 13 6.3 Durability tests Standard test cycles . 14 6.4 Door mass 16 6.5 Suitable for use on fire resistance / smoke control doors . 16 6.6 Safety 16 6.7 Corro

15、sion resistance and test of operation at extreme temperatures 16 6.7.1 Corrosion resistance 16 6.7.2 Test of operation at extreme temperatures 16 6.8 Key related Security 16 6.8.1 Minimum numbers of effective differs 16 6.8.2 Minimum number of movable detainer . 17 6.8.3 Maximum number of identical

16、steps . 17 EN 1303:2015 (E)BS EN 1303:20156.8.4 Direct coding on key . 17 6.8.5 Operation of the security mechanism. 17 6.8.6 Torque resistance of plug and/or cylinder . 17 6.9 Attack resistance 17 6.9.1 Resistance to drilling 17 6.9.2 Resistance to attack by chisel . 18 6.9.3 Resistance to attack b

17、y twisting . 19 6.9.4 Resistance to attack by plug/cylinder extraction 20 6.9.5 Torque resistance of plug/cylinder relevant to attack resistance . 24 7 Classification . 25 7.1 General . 25 7.2 Category of use (1st digit) 25 7.3 Durability (2nd digit) . 25 7.4 Door mass (3rd digit) 25 7.5 Suitable fo

18、r use on fire resistant / smoke control doors (4th digit) . 25 7.6 Safety (5th digit) 25 7.7 Corrosion resistance and temperature (6th digit) . 25 7.8 Key related security (7th digit) 26 7.9 Attack resistance (8th digit) . 26 8 Marking 26 Annex A (normative) Cylinders suitable for use on fire resist

19、ant / smoke control doors . 27 Annex B (informative) Tables of test sequence . 28 Annex C (informative) Product information . 29 Annex D (informative) Manufacturers declaration of compliance 30 Annex E (informative) Comparison table between EN 1303:2005 and EN 1303:2015 32 Bibliography . 33 EN 1303:

20、2015 (E) BS EN 1303:2015Foreword This document (EN 1303:2015) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, eith

21、er by publication of an identical text or by endorsement, at the latest by December 2015, and conflicting national standards shall be withdrawn at the latest by December 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN an

22、d/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1303:2005. The European Federation of Associations of Lock and Builders Hardware Manufacturers, ARGE, collaborated in the drafting of this European Standard. The main changes from th

23、e previous edition are to be found as follows: a) Definition 3.7: New definition for “movable detainer“; b) Subclause 4.7.2: Temperature change from 20 C and + 80 C to 25 C and + 65 C; c) Subclause 4.9.5: Plug extraction, two Grades A and B without extraction added; Grade C with 10 kN replaces grade

24、 1; Grade D replaces grade 2; d) Clause 5: Added headline: Test - General and test apparatus; e) Subclause 6.9.4: Plug extraction test method developed; f) Subclause 7.5: Grade 1 replaced with grade A and grade B (see Annex A); g) Subclause 7.9: Additional grades for attack resistance introduced; h)

25、 Subclause 7.9: New grading for attack resistance (0, A to D), see new Annex E; i) Annex A: Suitability for use on fire/smoke resistant doors (normative); j) Annex A: Grade A for smoke added. Grade 1 replaced with Grade B; k) Annex B: Tables of test sequence (informative); l) Annex C: Product inform

26、ation (informative); m) Annex D: Manufacturers declaration (informative); n) Annex E: Comparison table between EN 1303:2005 and EN 1303:2015 (informative). According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this E

27、uropean Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia,

28、Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. EN 1303:2015 (E)BS EN 1303:2015Introduction The aim of the test methods described in this standard is to keep human influence on the test results to a minimum, thus improving reproducibility. The suitability of cylinders for use on

29、 fire or smoke-door assemblies is determined by fire performance tests conducted in addition to the performance testing required by this standard. Since suitability for use on fire doors is not essential in every situation the manufacturer has the option to state if the cylinder conforms to these ad

30、ditional requirements or not. If so claimed, cylinders will comply with the requirements in Annex A. EN 1303:2015 (E) BS EN 1303:20151 Scope This European Standard applies to cylinders and their keys for such locks as are normally used in buildings and are designed to be used with cylinders, where t

31、he locks have an operational torque of maximum 1,2 Nm. This European Standard specifies performance and other requirements for the strength, security, durability, performance and corrosion resistance of cylinders and their original keys. It establishes one category of use, three grades of durability

32、, three grades for fire and four grades corrosion resistance all based on performance tests as well as six grades of key related security based on design requirements and five grades on performance tests that simulate attack. This European Standard includes tests of satisfactory operation at a range

33、 of temperatures. It specifies test methods to be used on cylinders and their protective measures linked with these cylinders and recommended by the manufacturer. Corrosion resistance is specified by reference to the requirements of EN 1670 on corrosion resistance of building hardware. The suitabili

34、ty of cylinders for use on fire or smoke-door assemblies is determined by fire performance tests conducted in addition to the performance testing required by this standard. Since suitability for use on fire doors is not essential in every situation the manufacturer has the option to state if the cyl

35、inder conforms to these additional requirements or not. If so claimed, cylinders will comply with the requirements in Annex A. On occasions there may be a need for additional functions within the design of the cylinder. Purchasers should satisfy themselves that the products are suitable for their in

36、tended use. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includi

37、ng any amendments) applies. EN 636, Plywood Specifications EN 1634-1, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows EN 1634-2, Fire resist

38、ance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and e

39、lements of building hardware - Part 3: Smoke control test for door and shutter assemblies EN 1670, Building hardware - Corrosion resistance - Requirements and test methods EN 1906:2012, Building hardware - Lever handles and knob furniture - Requirements and test methods EN ISO 10666, Drilling screws

40、 with tapping screw thread - Mechanical and functional properties (ISO 10666) EN ISO 15480, Hexagon washer head drilling screws with tapping screw thread (ISO 15480) EN 1303:2015 (E)BS EN 1303:2015EN ISO 15481, Cross recessed pan head drilling screws with tapping screw thread (ISO 15481) EN ISO 1548

41、2, Cross recessed countersunk head drilling screws with tapping screw thread (ISO 15482) EN ISO 15483, Cross recessed raised countersunk head drilling screws with tapping screw thread (ISO 15483) ISO 10899, High-speed steel two-flute twist drills Technical specifications 3 Terms and definitions For

42、the purpose of this document, the following terms and definitions apply. 3.1 cylinder device, usually distinct from its associated lock or latch, operated by a key 3.2 cam component of the cylinder to provide the movement to effect locking 3.3 effective differ difference between cylinders of similar

43、 design, achieved only by the movable detainer, which allows each cylinder to be operated only by its own key 3.4 direct code marking on the key where the key steps can be determined without reference to another data source 3.5 key separate device corresponding to the cylinder, which can mechanicall

44、y operate the cylinder 3.6 keyway aperture extending along the whole or part of the length of the plug into which the key is inserted 3.7 movable detainer permutable part of the mechanism of a cylinder which should first be moved by the key into a pre-determined position before the key and/or plug c

45、an move 3.8 plug part of a cylinder that can be moved when the proper key is used 3.9 steps characteristics of a key which operates movable detainers EN 1303:2015 (E) BS EN 1303:20154 Requirements 4.1 General The structure of this clause reflects the classification in accordance with Clause 7. 4.2 C

46、ategory of use Key strength The key shall not break under the applied torque of 2,5 Nm. After the test, the key shall be capable of being removed from the cylinder and re-used to operate the same cylinder with a torque not exceeding 1,5 Nm. Tested in accordance with 6.2. 4.3 Durability It shall be p

47、ossible to operate the cylinders with a new original key the number of test cycles specified in Table 1. Tested in accordance with 6.3. Table 1 Number of cycles Durability Number of cycles Grade 4 25 000 Grade 5 50 000 Grade 6 100 000 4.4 Door mass There is no requirement on the cylinder related to

48、the door mass. 4.5 Suitability for use on fire resistant / smoke control doors The cylinder shall conform to the requirements of Annex A. Verified in accordance with 6.5. 4.6 Safety There is no requirement on the cylinder related to safety. 4.7 Corrosion resistance and operation at extreme temperatu

49、res 4.7.1 Corrosion resistance It shall be possible to operate the cylinder with its proper key using a maximum torque of 1,5 Nm after tested according to grade 3 of EN 1670. This corrosion test shall apply to the functionality only. No distinction is made between the inside and the outside of cylinder and/or door. EN 1303:2015 (E)BS EN 1303:2015Tested in accordance with 6.7.1. 4.7.2 Operation at extreme temperatures It shall be possible to operate the cylinder with its proper key using a maximum torque of 1,5 Nm at both 25 C and + 65 C. Tes