1、BRITISH STANDARDBS EN 13063-1:2005Incorporating amendment no. 1Chimneys System chimneys with clay/ceramic flue liners Part 1: Requirements and test methods for sootfire resistanceThe European Standard EN 13063-1:2005, incorporating amendment A1:2007, has the status of a British StandardICS 91.060.40
2、g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 13063-1:2005This British Standard was published under the authority of the Standards Policy an
3、d Strategy Committee on 22 February 2006 BSI 2007ISBN 978 0 580 60205 4National forewordThis British Standard is the UK implementation of EN 13063-1:2005, incorporating amendment A1:2007.The UK participation in its preparation was entrusted by Technical Committee B/506, Chimneys, to Subcommittee B/5
4、06/3, Chimneys and their components having inner linings of clay or ceramic.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its corr
5、ect application. Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date Comments17364 28 September 2007 Implementation of CEN amendment A1:2007EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13063-1:2005+A1 July 2007 ICS
6、 91.060.40 Supersedes EN 13063-1:2005 English Version Chimneys - System chimneys with clay/ceramic flue liners - Part 1: Requirements and test methods for sootfire resistance Conduits de fumes - Conduits-systmes avec conduit intrieur en terre cuite/cramique - Partie 1: Exigences et mthodes dessai re
7、latives la dtermination de la rsistance au feu de chemine Abgasanlagen - System-Abgasanlagen mit Keramik-Innenrohren - Teil 1: Anforderungen und Prfungen fr Rubrandbestndigkeit This European Standard was approved by CEN on 2 September 2005 and includes Amendment 1 approved by CEN on 14 June 2007. CE
8、N members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on app
9、lication to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre
10、 has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
11、 Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by an
12、y means reserved worldwide for CEN national Members. Ref. No. EN 13063-1:2005+A1:2007: EEN 13063-1:2005+A1:2007 (E) 2 Contents page Foreword4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Shapes, dimensions and tolerances8 4.1 Flue liners .8 4.2 Insulation 8 4.3 Outer wall elements
13、.9 4.4 Cleaning and inspection doors 9 5 Material requirements .9 5.1 General requirements for components .9 5.2 Safety in use.11 5.3 Hygiene, health and environment 12 5.4 Cleaning and inspection doors 12 5.5 Freeze/thaw resistance .13 5.6 Temperature classes .13 5.7 Pressure classes13 6 Replacemen
14、t of single components of the system chimney 13 6.1 Change of flue liner .13 6.2 Change of opening sections.13 6.3 Change of insulation .14 6.4 Change of jointing materials for inner liners 14 6.5 Change of outer wall elements.14 6.6 Change of cleaning and inspection doors 14 7 Designation 14 8 Prod
15、uct information.15 9 Marking and labelling 16 10 Evaluation of conformity.16 10.1 General16 10.2 Components.16 10.3 Initial type testing of soot fire resistant system chimneys .17 10.4 Exchange of components .17 10.5 Factory production control.18 EN 13063-1:2005+A1:2007 (E) 3 Annex A (normative) Tes
16、t methods19 Annex B (normative) Stainless steel outer walls 25 Annex C (normative) Thermal resistance of the system chimney 26 Annex D (normative) Sampling procedures for an AQL of 10 % and inspection level S227 Annex ZA (informative) Clauses of this European Standard addressing the provisions of th
17、e EU Construction Product Directive .31 Bibliography38 EN 13063-1:2005+A1:2007 (E) 4 Foreword This document (EN 13063-1:2005+A1:2007) has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by UNI. This document shall be given the status of a national standar
18、d, either by publication of an identical text or by endorsement, at the latest by January 2008 and conflicting national standards shall be withdrawn at the latest by April 2009. This document includes Amendment 1 approved by CEN on 2007-06-14. This document supersedes EN 13063-1:2005. The start and
19、finish of text introduced or altered by amendment is indicated in the text by tags ! “. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship w
20、ith EU Directive(s), see informative Annex ZA which is an integral part of this document. This standard is part 1 of a series of standards for system chimneys with clay/ceramic flue liners. Part 2 is for system chimneys working under wet conditions and part 3 is for system air flue chimneys. Accordi
21、ng to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
22、 Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 13063-1:2005+A1:2007 (E) 5 1 Scope This European Standard specifies the requirements and test methods for multiwall soot fire resistant system chimneys
23、, working under dry conditions, with corrosion resistance 3, with negative pressure (see EN 1443) in which the products of combustion are conveyed to the atmosphere through clay/ceramic flue liners. Marking and inspection are also covered by this standard. This standard does not apply to structurall
24、y independent (free standing or self-supporting) system chimneys. A soot fire resistant system chimney has the following items where appropriate: clay/ceramic flue liners; Insulation layer; outer walls; mortar for jointing flue liners; mortar for jointing outer walls; terminal; chimney base; claddin
25、g; opening section; cleaning and inspection door; distance piece; reinforcement. The soot fire resistant chimney covers a combination of compatible chimney components, obtained or specified from one manufacturing source with product responsibility for the whole chimney. 2 Normative references The fo
26、llowing referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 998-2:2003, Specification for mortar for masonry Par
27、t 2: Masonry mortar EN 1366-8, Fire resistance tests for service installations Part 8: Smoke extraction ducts EN 1443:2003, Chimneys General requirements EN 1457:1999, Chimneys Clay/ceramic flue liners Requirements and test methods !EN 1806:2006“, Chimneys Clay/ceramic flue blocks for single wall ch
28、imneys Requirements and test methods EN 13063-1:2005+A1:2007 (E) 6 EN 1859, Chimneys Metal chimneys Test methods EN 12446:2003, Chimneys Components Concrete outer wall elements EN 13069:2005, Chimneys Clay/ceramic outer walls for system chimneys Requirements and test methods EN 13162:2001, Thermal i
29、nsulation products for buildings Factory made mineral wool (MW) products Specification EN 13216-1:2004, Chimneys Test methods for system chimneys Part 1: General test methods EN 13384-1, Chimneys - Thermal and fluid dynamic calculation methods Part 1: Chimneys serving one appliance !EN 13501-2, Fire
30、 classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services“ EN 14297:2004, Chimneys Freeze-thaw resistance test method for chimney products EN ISO 1182, Reaction to fire tests for building products Non-c
31、ombustibility test (ISO 1182:2002) ISO 2859-1, Sampling procedures for inspection by attributes Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 1443:
32、2003 and EN 13216-1:2004 and the following apply. 3.1 soot fire resistant multiwall system chimney multiwall construction, consisting mainly of an outer wall, an insulation layer and a sootfire resistant inner clay/ceramic flue liner. The combination of these components forms a sootfire resistant sy
33、stem chimney (see Figure 1) EN 13063-1:2005+A1:2007 (E) 7 Key 1 Inner liner 2 !Insulation layer (insulation or air gap)“ 3 Outer wall 4 Cavities for back ventilation 5 Cavities for structural reinforcement Figure 1 Construction of a soot fire resistant system chimney 3.2 chimney base section of the
34、system chimney, situated at the bottom, which comprises an inspection opening with door 3.3 reinforced outer wall outer wall having reinforcement to assist handling (not for structural stability) 3.4 structural reinforcement additional strengthening for structural stability (in the outer wall) 3.5 f
35、reeze-thaw-resistance ability of the product to resist the effects of freezing and thawing 3.6 opening section flue liner which has an opening for cleaning and inspection or connection for another flue (junction) 3.7 cleaning and inspection door door in outer wall element to allow cleaning and inspe
36、ction of the chimney. There are two types of cleaning and inspection doors (see Figure 2): - a cleaning and inspection door combined with an opening section with inner door - a cleaning and inspection door combined with an opening section without inner door EN 13063-1:2005+A1:2007 (E) 8 Key 1 Cleani
37、ng and inspection door 2 Inner door of the opening section 3 Opening section 4 Insulation layer 5 Outer wall Figure 2 - Examples of cleaning and inspection doors and the opening sections 3.8 distance piece spacer to keep distance between outer wall element and insulation or inner liner 4 Shapes, dim
38、ensions and tolerances 4.1 Flue liners 4.1.1 General Flue liners shall meet the requirements on size and tolerance of dimensions given in 7.1, 7.2, 7.3, 7.4, 7.5, 7.6 and 7.7 of EN 1457:1999. 4.1.2 External dimensions of flue liner When tested in accordance with A.2.6, the external dimensions of flu
39、e liners measured on any cross section shall not deviate more than 3 % of the manufacturers stated nominal external dimensions. 4.2 Insulation The insulation layer shall meet the requirements on tolerance of dimensions given in 4.2.2 (length and width) and 4.2.3 (thickness class T3) of EN 13162:2001
40、. EN 13063-1:2005+A1:2007 (E) 9 4.3 Outer wall elements Outer wall elements shall fulfil the requirements on shapes and tolerances on dimensions given in: concrete outer wall elements: EN 12446:2003, Clause 7 clay/ceramic outer walls: EN 13069:2005, Clause 6 metal outer walls: Annex B 4.4 Cleaning a
41、nd inspection doors Dimensions and tolerances shall be declared by the manufacturer. 5 Material requirements 5.1 General requirements for components 5.1.1 General All components of soot fire resistant system chimneys shall be non combustible in accordance to EN ISO 1182. 5.1.2 Clay/ceramic flue line
42、rs Flue liners shall meet the requirements of EN 1457 clauses: 8.1 Straight flue liners (proof load); 8.3 Minimum load for inspection opening sections (proof load); 9.1 Initial test (gas tightness, thermal shock resistance and resistance to fire for straight flue liners); 9.2 Final gas tightness aft
43、er thermal shock testing; 10 Acid resistance; 11 Water absorption and bulk density; 12 Sweeping resistance. 5.1.3 Maximum compressive strength for opening sections When tested as described in A.2.3, components shall withstand a load of at least five times the manufacturers declared design load. F =
44、( H G)/100 (1) where F = minimum load (kN); = safety factor = 5; H = height of chimney (m); EN 13063-1:2005+A1:2007 (E) 10 G = Weight per metre (kg/m). NOTE The limiting factor of the maximum height of system chimneys is the compressive strength of the opening section. 5.1.4 Jointing material for fl
45、ue liners 5.1.4.1 Density The density of jointing material shall not vary more than 10 % of the manufacturer declared value when tested in accordance to A.2.2.2. 5.1.4.2 Compressive strength The compressive strength shall be at least 10 N/mmwhen tested according to A.2.2.3. 5.1.5 Insulation 5.1.5.1
46、General The insulation shall be to the manufacturers specifications and shall be prefabricated and have an independent permanent shape before and after being exposed to heat in operating conditions (e.g. blocks or bonded loose material). 5.1.5.2 Density The manufacturer shall declare the density of
47、the insulation and this shall not vary by more than 10 % of the declared value and shall be tested according to !EN 1806:2006“, 17.15. 5.1.5.3 Durability under soot fire conditions When tested in accordance to A.2.1 the change in the outside surface temperature of the test sample after the fourth cy
48、cle of heating shall not exceed 10 % of the maximum outside surface temperature of the sample of the first cycle. 5.1.6 Outer wall elements The outer wall elements shall fulfil EN 12446 for concrete outer wall elements, EN 13069 for clay/ceramic outer wall or Annex B for stainless steel metal outer
49、walls. 5.1.7 Jointing material for outer wall elements Jointing materials used for jointing outer walls, where supplied with the system chimney, shall comply with the system chimney manufacturers declared specification and shall be at least M2,5 according to EN 998-2:2003, 5.3.1, Table 1. 5.1.8 Wind load The free standing part of the chimney above the last lateral support of the soot fire resistant system chimney shall withstand a wind load of 1,5 kN/m2. The