EN 13126-19-2011 en Building hardware - Requirements and test methods for windows and door height windows - Part 19 Sliding Closing Devices《建筑五金 窗户和门上窗的要求和试验方法 推拉关闭装置》.pdf

上传人:fuellot230 文档编号:707278 上传时间:2019-01-03 格式:PDF 页数:18 大小:1.23MB
下载 相关 举报
EN 13126-19-2011 en Building hardware - Requirements and test methods for windows and door height windows - Part 19 Sliding Closing Devices《建筑五金 窗户和门上窗的要求和试验方法 推拉关闭装置》.pdf_第1页
第1页 / 共18页
EN 13126-19-2011 en Building hardware - Requirements and test methods for windows and door height windows - Part 19 Sliding Closing Devices《建筑五金 窗户和门上窗的要求和试验方法 推拉关闭装置》.pdf_第2页
第2页 / 共18页
EN 13126-19-2011 en Building hardware - Requirements and test methods for windows and door height windows - Part 19 Sliding Closing Devices《建筑五金 窗户和门上窗的要求和试验方法 推拉关闭装置》.pdf_第3页
第3页 / 共18页
EN 13126-19-2011 en Building hardware - Requirements and test methods for windows and door height windows - Part 19 Sliding Closing Devices《建筑五金 窗户和门上窗的要求和试验方法 推拉关闭装置》.pdf_第4页
第4页 / 共18页
EN 13126-19-2011 en Building hardware - Requirements and test methods for windows and door height windows - Part 19 Sliding Closing Devices《建筑五金 窗户和门上窗的要求和试验方法 推拉关闭装置》.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 13126-19:2011Building hardware Requirements and testmethods for windows anddoor height windowsPart 19: Sliding Closing DevicesBS EN 13126-19:2011 BRITISH STANDARDNational f

2、orewordThis British Standard is the UK implementation of EN 13126-19:2011.The UK participation in its preparation was entrusted to TechnicalCommittee B/538/4, Building hardware.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not

3、purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 63822 0ICS 91.190Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStanda

4、rds Policy and Strategy Committee on 28 February 2011.Amendments issued since publicationDate Text affectedBS EN 13126-19:2011EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13126-19 February 2011 ICS 91.190 English Version Building hardware - Requirements and test methods for windows and door

5、height windows - Part 19: Sliding Closing Devices Quincaillerie pour le btiment - Exigences et mthodes dessai des ferrures de fentres et portes-fentres - Partie 19: Dispositifs de verrouillage pour ouvrants coulissants (SCD) Baubeschlge - Beschlge fr Fenster und Fenstertren - Anforderungen und Prfve

6、rfahren - Teil 19: Schiebeverschlsse (SCD) This European Standard was approved by CEN on 8 January 2011. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration

7、. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by t

8、ranslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Fi

9、nland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES

10、 KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13126-19:2011: EBS EN 13126-19:2011EN 13126-19:2011 (E) 2 Contents Page Foreword 31 Scope 42 Normative re

11、ferences 43 Terms and definitions . 44 Classification . 44.1 General 44.2 Category of use (1 first digit) . 54.3 Durability (2 second digit) 54.4 Mass (3 third digit) 54.5 Fire resistance (4 fourth digit) . 54.6 Safety in use (5 fifth digit) 54.7 Corrosion resistance (6 sixth digit) 54.8 Security (7

12、 seventh digit) . 54.9 Applicable part (8 eighth digit) 54.10 Test sizes Size limitations (9 ninth digit) 54.11 Example of classification for sliding closing devices . 65 Requirements . 65.1 General 65.2 Additional tests 65.2.1 Mechanical resistance . 65.2.2 Durability 65.2.3 Static load test . 76 T

13、est equipment 77 Test procedures (methods) 77.1 Samples 77.2 Durability test procedure 77.2.1 General 77.2.2 Implementation test for SCD manual action . 87.2.3 Implementation test for SCD Automatic action 87.2.4 Acceptance criteria 87.3 Static load test . 97.4 Corrosion resistance . 9Annex A (inform

14、ative) Test assembly . 11Annex B (Informative) SCDs and operating forces 13Annex C (Normative) Flow chart of test procedure . 14BS EN 13126-19:2011EN 13126-19:2011 (E) 3 Foreword This document (EN 13126-19:2011) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building h

15、ardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2011, and conflicting national standards shall be withdrawn at the l

16、atest by August 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. A full contribution to the preparation of this European Standard

17、 has been made by the European manufacturers organization ARGE and national standards bodies. This European Standard is one of a series of European Standards for building hardware products. It is divided into several parts incorporating all types of windows and balcony doors. According to the CEN/CE

18、NELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithua

19、nia, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 13126-19:2011EN 13126-19:2011 (E) 4 1 Scope This part of EN 13126 specifies requirements and test methods for durability, strength, security and functi

20、onality of Sliding Closing Devices (SCDs) for windows and door height windows. This European Standard does not specifically cover the handles used in handle-operated SCDs or the sash fasteners used in cam-operated SCDs, requirements and test methods for which are given in EN 13126-3 and EN 13126-14,

21、 respectively. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1670, Bu

22、ilding hardware Corrosion resistance Requirements and test methods EN 12519:2004, Windows and pedestrian doors Terminology EN 13126-1:2006, Building hardware Requirements and test methods for windows and doors height windows Part 1: Requirements common to all types of hardware ISO 4520, Chromate con

23、version coatings on electroplated zinc and cadmium coatings 3 Terms and definitions For the purposes of this document the definitions given in EN 13126-1:2006 and EN 12519:2004 and the following apply. 3.1 sliding Closing Device (SCD) device allowing the users to open and lock sliding windows and ba

24、lcony doors 3.2 SCD Manually action sliding closing device is actuated under the “finger operated” or “hand operated” action 3.3 SCD Automatic action SCD lock the sash when the sash is closed without any action more 3.4 PRD Position of Reference for Distance between sash and frame see Annex A, Figur

25、e A.2 4 Classification 4.1 General Sliding closing devices shall be classified in accordance with EN 13126-1:2006, Clause 4. BS EN 13126-19:2011EN 13126-19:2011 (E) 5 4.2 Category of use (1 first digit) The category of use shall be classified in accordance with EN 13126-1:2006, 4.2, with no marking.

26、 4.3 Durability (2 second digit) Durability shall be classified in accordance with EN 13126-1:2006, 4.3. 4.4 Mass (3 third digit) Mass shall be classified in accordance with EN 13126-1:2006, 4.4. 4.5 Fire resistance (4 fourth digit) One grade of fire resistance shall be identified in accordance with

27、 EN 13126-1:2006, 4.5: grade 0: no requirements. 4.6 Safety in use (5 fifth digit) One grade of safety in use shall be identified in accordance with EN 13126-1:2006, 4.6: grade 1: The hardware shall conform to this European Standard EN 13126-19. 4.7 Corrosion resistance (6 sixth digit) The corrosion

28、 resistance shall be classified in accordance with EN 13126-1:2006, 4.7. 4.8 Security (7 seventh digit) The security shall be classified in accordance with EN 13126-1:2006, 4.8, with no marking. 4.9 Applicable part (8 eighth digit) The eighth digit shall indicate the applicable part of the standard

29、that was used for testing the SCD, in accordance with EN 13126-1:2006, 4.9. One of two grades shall be allocated: grade 19/1: for use as SCD manually action; grade 19/2: for use as SCD automatic action. 4.10 Test sizes Size limitations (9 ninth digit) The ninth digit shall indicate the test size in

30、accordance with EN 13126-1:2006, 4.10 for example as follows: S.R.W.1) in mm / S.R.H.2) in mm tolerance 5 mm. EXAMPLE S.R.W =700/S.R.H=1200 NOTE 1 No test size is required for this category (Window type N). The specimen size shall be identified in the test, to full fill the ninth digit. NOTE 2 The s

31、pecified sizes are test sizes only. They do not relate to the maximum or minimum sizes to which a window could be fabricated. BS EN 13126-19:2011EN 13126-19:2011 (E) 6 NOTE 3 The manufacturers product-documentation should advise that in daily use windows smaller or larger than those tested should no

32、t be subjected to stronger forces than those for the specified test size. 1) S.R.W: Sash Rebate Width 2) S.R.H: Sash Rebate Height 4.11 Example of classification for sliding closing devices 1 2 3 4 5 6 7 8 9 - 3 40 0 1 2 - 19/2. S.R.W =700/ S.R.H=1200 This denotes sliding closing devices, which has:

33、 Digit 1 category of use - (no requirements) Digit 2 durability grade 3 (10 000 cycles) Digit 3 mass 40 Kg Digit 4 fire resistance grade 0 (no requirements) Digit 5 safety in use grade 1 Digit 6 corrosion resistance grade 2 Digit 7 security - (no requirements) Digit 8 applicable part 19/2 means SCD

34、Automatic action Digit 9 test sizes S.R.W =700/ S.R.H=1200 5 Requirements 5.1 General Sliding closing devices shall conform to Clause 5 of EN 13126-1:2006. 5.2 Additional tests 5.2.1 Mechanical resistance There shall be no breakage or deformation of any part during the test sufficient to prevent nor

35、mal operation of the sliding closing device. 5.2.2 Durability Grades shall conform to EN 13126-1:2006, 4.3. Before the durability test: The force/torque F1/M1 to operate the SCD shall be 20N / 2Nm when it is operated by finger or 30 N / 5Nm if it is operated by hand. The SCD shall function correctly

36、. After the durability test: The force/torque F1/M1 to operate the SCD shall be 20N / 2Nm when it is operated by finger or 30N / 5Nm if it is operated by hand. BS EN 13126-19:2011EN 13126-19:2011 (E) 7 The SCD shall continue to function correctly. The position of reference for Distance between sash

37、and frame (PRD) shall not vary by more than 2 mm, in accordance with 7.2. 5.2.3 Static load test On completion of the static load test in accordance with 7.3, the SCD shall continue to function correctly. 6 Test equipment The sliding closing devices shall be fitted to a test rig as specified in EN 1

38、3126-1:2006, Clause 6, using a simulated casement or sash in accordance with the manufacturers fixing instructions (see Annex A, Figure A.1), with a minimum mass of 15 kg. If there is no fitting location in the manufacturers fixing instructions, mount the sample sliding closing device and keep it to

39、 the centre of the vertical rail of casement or sash. Gaskets, brush or others elements shall not be applied to the specimen, in order to assure the free movement of the sash. 7 Test procedures (methods) 7.1 Samples According to the Annex C, three test samples shall be used for testing, as follows:

40、sample A performance tests (complete set) sample B corrosion tests (fitting set) sample C retained for reference control (fitting set) NOTE Sample B should only be necessary if no test report can be supplied by the manufacturer regarding the testing of the hardware component or set in accordance wit

41、h EN 1670. 7.2 Durability test procedure 7.2.1 General The test shall be carried out according to the following instructions: Before the durability test shall be applied, firstly record the force F1/ torque M1 necessary to operate the sliding closing device and check the correct functioning (see Tab

42、le 1). Secondly shall be applied the force F2 (see Figure A.2) and measure and record the PRD (Position Reference Distance). The durability test shall be implemented according to 7.2.2 or 7.2.3. After the durability test, the force F1/ torque M1 necessary to operate the sliding closing device shall

43、be applied again, this force shall be recorded and the correct functioning shall be checked (see Table 1). BS EN 13126-19:2011EN 13126-19:2011 (E) 8 Force F2 (see Annex A, Figure A.2) shall be applied again and measure and record the position reference distance (PRD). The SCD shall be lubricated in

44、accordance with the manufacturers installation and maintenance instructions unless the hardware is claimed to be maintenance-free. 7.2.2 Implementation test for SCD manual action NOTE For the realization of this test, it will not be necessary for the displacement (movement) of the sash, for what the

45、 test will only validate the correct operation of the mechanism of SCD. The SCD shall be operated for lock and unlock for the cycles number according the grade to test at a rate of 250 cycles /h 250+cycles / h. 7.2.3 Implementation test for SCD Automatic action For the realization of this test it wi

46、ll be necessary the displacement (movement) of the sash, a distance of 200 mm with a rate of 250 cycles /h 250+cycles / h. The test cycles on the test specimen shall consist of the following movements: initially, the sash shall be in the closed position (SCD locked); the SCD shall be unlocked; the s

47、ash shall be moved into the open position (200 mm); the SCD shall set free; the fall of the test mass shall be the cause of the displacement of the sash to the closed position (SCD shall be in the locked position). The test mass shall be connected by a cable to the test specimen near the window SCD.

48、 The cable length shall be selected so that the test mass comes to a halt 20 mm before the sash reaches its final position and locks the hook into the keeper. 7.2.4 Acceptance criteria Some marking of the SCD as a result of the falling test mass shall be deemed to be acceptable. After the durability

49、 test the SCD shall function correctly, according to the following criteria: The force F1 / torque M1 to operate the SCD shall be 20 N. / 2 Nm when it is operated by finger or 30N / 5Nm if it is operated by hand. The variation on PRD before and after the durability test shall be 2 mm. BS EN 13126-19:2011EN 13126-19:2011 (E) 9 7.3 Static load test Apply static load F3= n x 200 N 100+for 60 s 100+(see

展开阅读全文
相关资源
猜你喜欢
  • ASTM D4798 D4798M-2010 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method).pdf ASTM D4798 D4798M-2010 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method).pdf
  • ASTM D4798 D4798M-2011 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)《沥青材料的加速老化试验条件和程序的标准操作规程(氙弧法)》.pdf ASTM D4798 D4798M-2011 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)《沥青材料的加速老化试验条件和程序的标准操作规程(氙弧法)》.pdf
  • ASTM D4798 D4798M-2011(2016) Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)《沥青材料加速老化试验条件和程序的标准实施规程 (氙弧法)》.pdf ASTM D4798 D4798M-2011(2016) Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)《沥青材料加速老化试验条件和程序的标准实施规程 (氙弧法)》.pdf
  • ASTM D4798-2004 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)《沥青材料的加速老化试验条件和程序的标准规程(氙弧法)》.pdf ASTM D4798-2004 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)《沥青材料的加速老化试验条件和程序的标准规程(氙弧法)》.pdf
  • ASTM D4798-2008 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method).pdf ASTM D4798-2008 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method).pdf
  • ASTM D4799 D4799M-2008(2013)e1 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Met.pdf ASTM D4799 D4799M-2008(2013)e1 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Met.pdf
  • ASTM D4799 D4799M-2017 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Method)《沥青材.pdf ASTM D4799 D4799M-2017 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Method)《沥青材.pdf
  • ASTM D4799-2003 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Method)《沥青材料加速风化试验.pdf ASTM D4799-2003 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Method)《沥青材料加速风化试验.pdf
  • ASTM D4799-2008 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Method)《沥青材料加速风化试验.pdf ASTM D4799-2008 Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV Water Spray and Condensation Method)《沥青材料加速风化试验.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1