1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 13126-9:2013Building hardware Requirements and testmethods for windows anddoor height windowsPart 9: Hardware for horizontal and verticalpivot windowsBS EN 13126-9:2013 BRI
2、TISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13126-9:2013.It supersedes DD CEN/TS 13126-9:2004 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/538/4, Building hardware.A list of organizations represented on this c
3、ommittee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 75389 3ICS 91.190
4、Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 28 February 2013.Amendments issued since publicationDate Text affectedBS EN 13126-9:2013EUROPEAN STANDARD NORME EUR
5、OPENNE EUROPISCHE NORM EN 13126-9 February 2013 ICS 91.190 Supersedes CEN/TS 13126-9:2004English Version Building hardware - Requirements and test methods for windows and door height windows - Part 9: Hardware for horizontal and vertical pivot windows Quincaillerie pour le btiment - Exigences et met
6、hodes dessai des ferrures de fentres et portes-fentres - Partie 9: Ferrures pour fentres basculantes et pivotantes Baubeschlge - Anforderungen und Prfverfahren fr Fenster und Fenstertren - Teil 9: Beschlge fr Schwing- und Wendefenster This European Standard was approved by CEN on 14 December 2012. C
7、EN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on ap
8、plication to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
9、Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, L
10、atvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-
11、1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13126-9:2013: EBS EN 13126-9:2013EN 13126-9:2013 (E) 2 Contents Page Foreword . 4 1 Scope 6 2 Normative references . 6 3 Terms and definitions 6 4 Classification 7
12、4.1 General . 7 4.2 Category of use (1 first digit) 7 4.3 Durability (2 second digit) . 7 4.4 Mass (3 third digit) 7 4.5 Fire resistance (4 fourth digit) 7 4.6 Safety in use (5 fifth digit) . 7 4.7 Corrosion resistance (6 sixth digit) 7 4.8 Security (7 seventh digit) 7 4.9 Application (8 eighth digi
13、t) 8 4.10 Test sizes (9 - ninth digit). 8 4.10.1 Window size for horizontal pivot windows . 8 4.10.2 Window size for vertical pivot windows 8 4.11 Example of classification for horizontal and vertical pivot windows 8 5 Requirements . 9 5.1 General . 9 5.2 Durability 9 5.3 Locking point variable tole
14、rance . 9 5.4 Handle operation tolerance . 10 5.5 Balance test for pivot hinges with integrated braking function . 10 5.6 Resistance to static load 10 5.7 Resistance to free fall test for horizontal pivot windows . 10 5.8 Resistance to rebate hindrance test for vertical pivot windows 10 5.9 Minimum
15、closing devices resistance 10 5.10 Corrosion test 10 6 Test equipment . 11 7 Test methods 11 7.1 Samples 11 7.2 Test order . 11 7.3 Durability test . 12 7.3.1 Durability test of normal opening 12 7.3.2 Reversed position durability test 13 7.4 Balance tests 14 7.5 Static Tests . 14 7.5.1 Ventilation
16、position static test on horizontal pivot windows . 14 7.5.2 Ventilation position static test on vertical pivot windows 15 7.5.3 Reversed position static test on horizontal pivot windows . 16 7.5.4 Reversed position static test on vertical pivot windows 17 7.6 Free fall test for horizontal pivot wind
17、ows 18 7.7 Rebate hindrance test for vertical pivot windows 18 7.8 Minimum closing device resistance test . 19 7.9 Corrosion resistance . 19 Annex A (informative) Test equipment . 21 BS EN 13126-9:2013EN 13126-9:2013 (E) 3 Annex B (normative) Flowchart of test procedures . 22 Bibliography 24 BS EN 1
18、3126-9:2013EN 13126-9:2013 (E) 4 Foreword This document (EN 13126-9:2013) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling - Building hardware”, the secretariat of which is held by AFNOR. This European Standard shall be given the sta
19、tus of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2013, and conflicting national standards shall be withdrawn at the latest by August 2013. Attention is drawn to the possibility that some of the elements of this document may be the subj
20、ect of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes CEN/TS 13126-9:2004. EN 13126 is composed of the following parts: EN 13126-1, Building hardware Hardware for windows and door height windows Requirements and
21、 test methods Part 1: Requirements common to all types of hardware; EN 13126-2, Building hardware Requirements and test methods for windows and doors height windows Part 2: Window fastener handles; EN 13126-3, Building hardware Hardware for windows and door-height windows Requirements and test metho
22、ds Part 3: Handles, primarily for Tilt EN 13126-4, Building hardware Requirements and test methods for windows and doors height windows Part 4: Espagnolettes; EN 13126-5, Building hardware Hardware for windows and door height windows Requirements and test methods Part 5: Devices that restrict the op
23、ening of windows and door height windows; EN 13126-6, Building hardware Requirements and test methods for windows and doors height windows Part 6: Variable geometry stay hinges (with or without a friction stay); EN 13126-7, Building hardware Requirements and test methods for windows and door height
24、windows Part 7: Finger catches; EN 13126-8, Building hardware Requirements and test methods for windows and doors height windows Part 8: Tilt EN 13126-9, Building hardware Hardware for windows and door height windows Part 9: Hardware for horizontal and vertical pivot windows (the present document);
25、EN 13126-10, Building hardware Requirements and test methods for windows and doors height windows Part 10: Arm-balancing systems; EN 13126-11, Building hardware Requirements and test methods for windows and doors height windows Part 11: Top hung projecting reversible hardware; EN 13126-12, Building
26、hardware Requirements and test methods for windows and doors height windows Part 12: Side hung projecting reversible hardware; BS EN 13126-9:2013EN 13126-9:2013 (E) 5 EN 13126-13, Building hardware Hardware for windows and balcony doors Requirements and test methods Part 13: Sash balances; EN 13126-
27、14, Building hardware Hardware for windows and balcony doors Requirements and test methods Part 14: Sash fasteners; EN 13126-15, Building hardware Requirements and test methods for windows and doors height windows Part 15: Rollers for horizontal sliding and sliding folding windows and doors; EN 1312
28、6-16, Building hardware Requirements and test methods for windows and doors height windows Part 16: Hardware for Lift EN 13126-17, Building hardware Requirements and test methods for windows and doors height windows Part 17: Hardware for Tilt prEN 13126-18, Building hardware Specifications for the f
29、ittings for the operation of windows and door height windows Part 18: Requirements and test procedures for durability, strength, security and functionality of Fan light openers for windows and door height windows EN 13126-19, Building hardware Requirements and test methods for windows and door heigh
30、t windows Part 19: Sliding Closing Devices. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former
31、 Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 13126-9:2013EN 13126-9:2013 (E) 6 1 S
32、cope This European Standard specifies the requirements and test methods for durability and strength of hardware for vertical and horizontal pivot windows and door height windows (including pivot hinges and central locking systems). If the hardware manufacturer would like to classify an integrated re
33、strictor function, the pivot hinges may be tested in accordance with EN 13126-5. This European Standard does not apply to manoeuvring devices which are covered in EN 13126-2, EN 13126-3, EN 13126-7, EN 13126-14 and prEN 13126-18. 2 Normative references The following documents, in whole or in part, a
34、re normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1670, Building hardware Corrosion resistance Requir
35、ements and test methods EN 12519:2004, Windows and pedestrian doors Terminology EN 13126-1, Building hardware Hardware for windows and door height windows Requirements and test methods Part 1: Requirements common to all types of fittings 3 Terms and definitions For the purposes of this document, the
36、 terms and definitions given in EN 12519:2004 and the following apply. 3.1 fastened closed position position in which the active sash rests against the frame or compresses the gaskets on all sides, and the central locking system is fully engaged 3.2 closed position position in which the active sash
37、rests against the frame or compresses the gaskets on all sides, and the central locking system is not engaged 3.3 opened position position in which the active sash is at a predefined opening angle (normally 45) or the maximum opening travel of the operated window 3.4 reversed position position in wh
38、ich the active sash has been rotated past the opening position until the internal and external faces of the active sash are inverted 3.5 limiting restrictor device equipped with a maximum opening stop, intended to limit the movement of a sash to a predetermined position BS EN 13126-9:2013EN 13126-9:
39、2013 (E) 7 3.6 rest time time, in seconds, of a stationary period either: between two changes of direction of movement; between the completion of a movement of the active sash and the subsequent operation of the central locking system; between the completion of an operation of the central locking sy
40、stem and the subsequent movement of the active sash; between two cycles 3.7 central locking system hardware used all round or only partially to fasten the active sash 4 Classification 4.1 General The hardware classification shall be in accordance with the requirements in EN 13126-1. 4.2 Category of
41、use (1 first digit) No marking is required for the category of use. 4.3 Durability (2 second digit) Grades shall be in accordance with EN 13126-1. 4.4 Mass (3 third digit) Grades shall be in accordance with EN 13126-1. 4.5 Fire resistance (4 fourth digit) Grades shall be in accordance with EN 13126-
42、1. 4.6 Safety in use (5 fifth digit) Grades shall be in accordance with EN 13126-1. 4.7 Corrosion resistance (6 sixth digit) Grades shall be in accordance with EN 13126-1. 4.8 Security (7 seventh digit) Grades shall be in accordance with EN 13126-1. BS EN 13126-9:2013EN 13126-9:2013 (E) 8 4.9 Applic
43、ation (8 eighth digit) Three grades are identified: 9/1: hardware for horizontal pivot windows, with braking function; 9/2: hardware for horizontal pivot windows, without braking function; 9/3: hardware for vertical pivot windows. 4.10 Test sizes (9 - ninth digit) 4.10.1 Window size for horizontal p
44、ivot windows The window size for horizontal pivot windows is SRW1)1 600 mm X SRH2)1 400 mm or SRD3) 1 400 mm. In the case of not being capable of manufacturing the specified test size due to the fact that the hardware field of application is smaller than this specified test size, a smaller test size
45、 shall be used. In this case the window shall be tested in accordance with the largest possible SRW (or SRH) as specified by the hardware manufacturers appropriate documentation and a SRH (or SRW) in a ratio of 8:7. 4.10.2 Window size for vertical pivot windows The window size for vertical pivot win
46、dows is SRW1)1 400 mm x SRH2)1 600 mm or SRD3) 1 400 mm. In the case of not being capable of manufacturing the specified test size due to the fact that the hardware field of application is smaller than this specified test size, a smaller test size shall be used. In this case the window shall be test
47、ed in accordance with the largest possible SRW (or SRH) as specified by the hardware manufacturers appropriate documentation and a SRH (or SRW) in a ratio of 7:8. 4.11 Example of classification for horizontal and vertical pivot windows 1 2 3 4 5 6 7 8 9 - 4 120 0 1 4 - 9/1 1 600/1 400 This denotes h
48、ardware for horizontal and vertical pivot windows, which have: Digit 1 category of use - (no requirements) Digit 2 durability grade 4 (15 000 cycles) Digit 3 mass 120 kg Digit 4 fire resistance grade 0 (no requirements) Digit 5 safety in use grade 1 1) SRW = Sash Rebate Width. 2) SRH = Sash Rebate H
49、eight. 3) SRD = Sash Rebate Diameter. BS EN 13126-9:2013EN 13126-9:2013 (E) 9 Digit 6 corrosion resistance grade 4 Digit 7 security - (no requirements) Digit 8 applicable part grade 9/1 (hardware for horizontal pivot windows with braking function) Digit 9 test sizes SRW4)= 1 600 mm, SRH5)= 1 400 mm 5 Requirements 5.1 General The hardware requirements shall be in accord