EN 13205-1-2014 en Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1 General requirements《工作地暴露 悬浮颗粒浓度采样器性能评定 第1部分.pdf

上传人:twoload295 文档编号:707436 上传时间:2019-01-03 格式:PDF 页数:36 大小:1.40MB
下载 相关 举报
EN 13205-1-2014 en Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1 General requirements《工作地暴露 悬浮颗粒浓度采样器性能评定 第1部分.pdf_第1页
第1页 / 共36页
EN 13205-1-2014 en Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1 General requirements《工作地暴露 悬浮颗粒浓度采样器性能评定 第1部分.pdf_第2页
第2页 / 共36页
EN 13205-1-2014 en Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1 General requirements《工作地暴露 悬浮颗粒浓度采样器性能评定 第1部分.pdf_第3页
第3页 / 共36页
EN 13205-1-2014 en Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1 General requirements《工作地暴露 悬浮颗粒浓度采样器性能评定 第1部分.pdf_第4页
第4页 / 共36页
EN 13205-1-2014 en Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1 General requirements《工作地暴露 悬浮颗粒浓度采样器性能评定 第1部分.pdf_第5页
第5页 / 共36页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 13205-1:2014Workplace exposure Assessment of samplerperformance for measurementof airborne particleconcentrationsPart 1: General requirementsBS EN 13205-1:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13205-1:2014.Together w

2、ith BS EN 13205-2:2014, PD CEN/TR 13205-3, BS EN13205-4:2014, BS EN 13205-5:2014 and BS EN 13205-6:2014 itsupersedes BS EN 13205:2002, which will be withdrawn uponpublication of all parts of the series.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/2, Work place atm

3、ospheres.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by BSI

4、 StandardsLimited 2014ISBN 978 0 580 78058 5ICS 13.040.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June 2014.Amendments issued since publicationDate Text

5、affectedBS EN 13205-1:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13205-1 June 2014 ICS 13.040.30 Supersedes EN 13205:2001English Version Workplace exposure - Assessment of sampler performance for measurement of airborne particle concentrations - Part 1: General requirements Exposition

6、sur les lieux de travail - valuation des performances des dispositifs de prlvement pour le mesurage des concentrations de particules en suspension dans lair - Partie 1: Exigences gnrales Exposition am Arbeitsplatz - Beurteilung der Leistungsfhigkeit von Sammlern fr die Messung der Konzentration luft

7、getragener Partikel - Teil 1: Allgemeine Anforderungen This European Standard was approved by CEN on 7 May 2014. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any al

8、teration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language m

9、ade by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Est

10、onia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STA

11、NDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13205-1:2014 EBS EN 13205-1:2014EN 132

12、05-1:2014 (E) 2 Contents Page Foreword 3 Introduction . 5 1 Scope 6 2 Normative references 6 3 Terms and definitions . 7 3.1 Terms related to sampling and transportation . 7 3.2 Terms related to performance 11 4 Symbols and abbreviations 12 4.1 Symbols 12 4.1.1 Latin 12 4.1.2 Greek . 13 5 Requiremen

13、ts . 14 5.1 Summary of requirements 14 5.2 Expanded uncertainty for an aerosol sampler . 14 5.3 Expanded uncertainty for a measuring procedure 15 6 Test methods 16 6.1 General 16 6.2 Critical review in order to delimit the performance test 19 6.3 Overview of test methods . 20 7 Types of evaluation .

14、 21 7.1 Sampler evaluation 21 7.2 Evaluation of a measuring procedure . 21 8 Instructions for use . 21 9 Marking, quality control 22 9.1 Marking . 22 9.2 Quality control 22 Annex A (normative) Calculation of expanded uncertainty for a measuring procedure . 23 Bibliography 31 BS EN 13205-1:2014EN 132

15、05-1:2014 (E) 3 Foreword This document (EN 13205-1:2014) has been prepared by Technical Committee CEN/TC 137 “Assessment of workplace exposure to chemical and biological agents”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either

16、by publication of an identical text or by endorsement, at the latest by December 2014 and conflicting national standards shall be withdrawn at the latest by December 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or

17、 CENELEC shall not be held responsible for identifying any or all such patent rights. This document together with EN 13205-2, CEN/TR 13205-3, EN 13205-4, EN 13205-5 and EN 13205-6 will supersede EN 13205:2001. EN 13205, Workplace exposure Assessment of sampler performance for measurement of airborne

18、 particle concentrations, consists of the following parts: Part 1: General requirements (the present document); Part 2: Laboratory performance test based on determination of sampling efficiency; Part 3: Analysis of sampling efficiency data Technical Report; Part 4: Laboratory performance test based

19、on comparison of concentrations; Part 5: Aerosol sampler performance test and sampler comparison carried out at workplaces; Part 6: Transport and handling tests. Significant technical changes from the previous edition, EN 13205:2001: This part of EN 13205 is based on Clauses 1 to 8 of the previous e

20、dition, EN 13205:2001. The scope has been limited to aerosol samplers, and the current version of the standard is not (directly) applicable to other types of aerosol instruments. The list of definitions has been expanded and many definitions are now given in EN 1540, Workplace exposure Terminology.

21、The method of calculating the uncertainty of a sampler or a measuring procedure has been revised in order to comply with ENV 13005. The concept of “overall uncertainty” is no longer used, instead the concept of “expanded uncertainty” is used. The list of Requirements (Table 1) has been reformulated/

22、changed for some attributes. The current version of the standard envisages two different types of tests: A test of a candidate aerosol sampler and a test of a complete measuring method based on a candidate sampler, respectively. Two flow charts, one for each type of test, have been included to bette

23、r demonstrate the relation between the different parts of EN 13205. Annex A has been added on how to calculate the expanded uncertainty for a measuring procedure based on aerosol sampling but also consisting of several other stages. This is a complete revision and expansion of Annex E in the previou

24、s version. A clause on symbols has been included. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland,

25、Former Yugoslav Republic of Macedonia, France, Germany, Greece, BS EN 13205-1:2014EN 13205-1:2014 (E) 4 Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdo

26、m. BS EN 13205-1:2014EN 13205-1:2014 (E) 5 Introduction EN 481 defines sampling conventions for the particle size fractions to be collected from workplace atmospheres in order to assess their impact on human health. Conventions are defined for the inhalable, thoracic and respirable aerosol fractions

27、. These conventions represent target specifications for aerosol samplers, giving the ideal sampling efficiency as a function of particle aerodynamic diameter. In general, the sampling efficiency of real aerosol samplers will deviate from the target specification, and the aerosol mass collected will

28、therefore differ from that which an ideal sampler would collect. In addition, the behaviour of real samplers is influenced by many factors such as external wind speed. In many cases there is an interaction between the influence factors and fraction of the airborne particle size distribution of the e

29、nvironment in which the sampler is used. EN 482 contains general performance requirements for methods used for determining the concentrations of chemical agents in workplace atmospheres. These performance requirements include maximum values of expanded uncertainty (a combination of random and non-ra

30、ndom measurement uncertainty) achievable under prescribed laboratory conditions for the methods to be used. The requirements of EN 482 apply to a complete measuring procedure, a combination of the stages consisting of sampling, sample transport/storage and sample preparation/analysis. This part of E

31、N 13205 gives performance requirements for samplers for the inhalable, thoracic or respirable aerosol fractions. Requirements for the aerosol sampler and transport of loaded collection samplers are stated. Furthermore, the method for calculating the expanded uncertainty for a measuring procedure bas

32、ed on aerosol sampling is described. Different test procedures and types of evaluation are described in the other parts of EN 13205 in order to enable application of EN 13205 to a wide variety of instruments. In detail, three different performance tests for sampled concentration and a transport test

33、 of loaded collection substrates are described. The three tests differ in the amount of information obtained by the test and its corresponding cost. The first test method determines the sampling efficiency curve of a candidate sampler, the second compares concentrations sampled from three laboratory

34、 test atmospheres by a candidate sampler and a (previously) validated sampler, and the third method compares concentrations sampled from a specific workplace by a candidate sampler and a (previously) validated sampler. Additionally a method for determining equivalence between aerosol samplers at spe

35、cific workplaces and an alternative handling test are presented. EN 13205 (all parts) enables manufacturers and users of aerosol samplers to adopt a consistent approach to sampler validation, and provide a framework for the assessment of sampler performance with respect to EN 481 and EN 482. It is t

36、he responsibility of the manufacturer of aerosol samplers to inform the user of the sampler performance under the laboratory conditions1)specified in other parts of this European Standard. It is the responsibility of the user to ensure that the actual conditions of intended use are within what the m

37、anufacturer specifies as acceptable conditions according to the performance test. 1) The inhalable convention is undefined for particle sizes in excess of 100 m or for wind speeds greater than 4 m/s. The tests required to assess performance are therefore limited to these conditions. Should such larg

38、e particle sizes or wind speeds actually exist at the time of sampling, it is possible that different samplers meeting this part of EN 13205 give different results. BS EN 13205-1:2014EN 13205-1:2014 (E) 6 1 Scope This European Standard specifies performance requirements that are specific to aerosol

39、samplers, primarily inhalable, thoracic and respirable aerosol samplers. These performance requirements, which include conformity with the EN 481 sampling conventions, are applicable only to the process of sampling the airborne particles from the air, not to the process of analysing particles collec

40、ted by the process of sampling. Although analysis of samples collected in the course of testing is usually necessary in order to evaluate the sampler performance, the specified test methods ensure that analytical errors are kept very low during testing and do not contribute significantly to the end

41、result. This part of EN 13205 specifies how the performance of aerosol measuring procedures is assessed with respect to the general requirements of EN 482, through the combination of errors arising in the sampling, sample transportation/storage and sample preparation/analysis stages. This part of EN

42、 13205 is applicable to all samplers used for the health-related sampling of particles in workplace air. This part of EN 13205 is not applicable to the determination of analytical errors and factors related to them (for example the bias, precision and limit of detection of the analytical method). Wh

43、ere the aerosol sampler requires the use of an external (rather than integral) pump, the pump is not subject to the requirements of this part of EN 13205. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its ap

44、plication. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 481, Workplace atmospheres Size fraction definitions for measurement of airborne particles EN 482:2012, Workplace exposure Gen

45、eral requirements for the performance of procedures for the measurement of chemical agents EN 1540:2011, Workplace exposure Terminology EN 13205-2:2014, Workplace exposure Assessment of sampler performance for measurement of airborne particle concentrations Part 2: Laboratory performance test based

46、on determination of sampling efficiency CEN/TR 13205-3, Workplace exposure Assessment of sampler performance for measurement of airborne particle concentrations Part 3: Analysis of sampling efficiency data EN 13205-4:2014, Workplace exposure Assessment of sampler performance for measurement of airbo

47、rne particle concentrations Part 4: Laboratory performance test based on comparison of concentrations EN 13205-5:2014, Workplace exposure Assessment of sampler performance for measurement of airborne particle concentrations Part 5: Aerosol sampler performance test and sampler comparison carried out

48、at workplaces EN 13205-6:2014, Workplace exposure Assessment of sampler performance for measurement of airborne particle concentrations Part 6: Transport and handling tests EN 13890, Workplace exposure Procedures for measuring metals and metalloids in airborne particles Requirements and test methods

49、 BS EN 13205-1:2014EN 13205-1:2014 (E) 7 EN 14530, Workplace atmospheres Determination of diesel particulate matter General requirements EN ISO 13137, Workplace atmospheres Pumps for personal sampling of chemical and biological agents Requirements and test methods (ISO 13137) ISO 15767, Workplace atmospheres Controlling and characterizing uncertainty in weighing collected aerosols ISO 21438 (all parts), Workplace atmospheres Determination of inorganic acids by ion chromatography ISO 24095, Workplace air

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1