EN 1363-1-2012 en Fire resistance tests - Part 1 General Requirements《耐火试验 一般要求》.pdf

上传人:towelfact221 文档编号:708071 上传时间:2019-01-03 格式:PDF 页数:56 大小:1.41MB
下载 相关 举报
EN 1363-1-2012 en Fire resistance tests - Part 1 General Requirements《耐火试验 一般要求》.pdf_第1页
第1页 / 共56页
EN 1363-1-2012 en Fire resistance tests - Part 1 General Requirements《耐火试验 一般要求》.pdf_第2页
第2页 / 共56页
EN 1363-1-2012 en Fire resistance tests - Part 1 General Requirements《耐火试验 一般要求》.pdf_第3页
第3页 / 共56页
EN 1363-1-2012 en Fire resistance tests - Part 1 General Requirements《耐火试验 一般要求》.pdf_第4页
第4页 / 共56页
EN 1363-1-2012 en Fire resistance tests - Part 1 General Requirements《耐火试验 一般要求》.pdf_第5页
第5页 / 共56页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 1363-1:2012Fire resistance testsPart 1: General RequirementsBS EN 1363-1:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1363-1:2

2、012. It supersedes BS EN 1363-1:1999, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee FSH/22/-/7, Non loadbearing separating elements.A list of organizations represented on this committee can be obtained on request to its secretary.This publication doe

3、s not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 76353 3 ICS 13.220.50 Compliance with a British Standard cannot confer immunity from leg

4、al obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2012.Amendments issued since publicationDate T e x t a f f e c t e dBS EN 1363-1:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1363-1 July 2012 ICS 13.220.50

5、Supersedes EN 1363-1:1999English Version Fire resistance tests - Part 1: General Requirements Essais de rsistance au feu - Partie 1: Exigences gnrales Feuerwiderstandsprfungen - Teil 1: Allgemeine Anforderungen This European Standard was approved by CEN on 9 June 2012. CEN members are bound to compl

6、y with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC

7、Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the sam

8、e status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,

9、 Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All ri

10、ghts of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1363-1:2012: EBS EN 1363-1:2012EN 1363-1:2012 (E) 2 Contents Page Foreword 5Introduction .61 Scope 72 Normative references 73 Terms, definitions, symbols and designations 83.1 Terms and definit

11、ions .83.2 Symbols and designations 104 Test equipment . 104.1 General . 104.2 Furnace 114.3 Loading equipment . 114.4 Test frames 114.5 Instrumentation . 124.5.1 Temperature 124.5.2 Pressure . 134.5.3 Load . 134.5.4 Deflection . 134.5.5 Integrity 134.6 Precision of measuring equipment . 145 Test co

12、nditions . 145.1 Furnace temperature 145.1.1 Heating curve 145.1.2 Tolerances . 145.2 Furnace pressure 155.2.1 General . 155.2.2 Establishing the neutral pressure plane 165.3 Furnace atmosphere 165.4 Loading 165.5 Restraint/boundary conditions 165.6 Ambient temperature conditions 175.7 Deviation fro

13、m required test conditions 176 Test specimen(s). 176.1 Size . 176.2 Number 176.2.1 Separating elements . 176.2.2 Non-separating elements . 176.3 Design 176.4 Construction 186.5 Verification 187 Installation of test specimen . 187.1 General . 187.2 Supporting constructions 187.2.1 General . 187.2.2 S

14、tandard supporting constructions 197.2.3 Non-standard supporting constructions 218 Conditioning 218.1 Test specimen . 21BS EN 1363-1:2012EN 1363-1:2012 (E) 3 8.2 Supporting constructions 219 Application of instrumentation 219.1 Thermocouples 219.1.1 Furnace thermocouples (plate thermometers) . 219.1

15、.2 Unexposed surface thermocouples 229.1.3 Internal thermocouples . 239.2 Pressure . 239.2.1 General . 239.2.2 Furnaces for vertical elements 239.2.3 Furnaces for horizontal elements 239.3 Deflection . 2310 Test procedure . 2410.1 Restraint application . 2410.2 Load application 2410.3 Commencement o

16、f test . 2410.4 Measurements and observations 2410.4.1 General . 2410.4.2 Temperatures . 2410.4.3 Furnace pressure 2510.4.4 Deflection . 2510.4.5 Integrity 2510.4.6 Load and restraints . 2610.4.7 General behaviour . 2610.5 Termination of test 2611 Performance criteria 2711.1 Loadbearing capacity 271

17、1.2 Integrity 2711.3 Insulation 2811.4 Consequential effects of failing certain performance criteria 2811.4.1 Insulation and integrity versus loadbearing capacity . 2811.4.2 Insulation versus integrity 2812 Test report 2812.1 Test report 2812.2 Expression of test results in the test report . 30Annex

18、 A (informative) Field of application of test results 39A.1 General . 39A.2 Field of direct application . 39A.3 Extended application 39Annex B (informative) The role of supporting constructions . 40B.1 General . 40B.2 Standard supporting constructions 40B.3 Non-standard supporting constructions 40An

19、nex C (informative) General information on thermocouples . 42C.1 Furnace thermocouples (plate thermometers) . 42C.1.1 Maintenance . 42C.1.2 Positioning . 42C.2 Internal thermocouples . 42C.2.1 General . 42C.2.2 Specification 42C.2.3 Fixing methods and positioning 42C.3 Unexposed face thermocouples 4

20、3C.3.1 General . 43C.3.2 Positioning . 43C.3.3 Fixing to specific materials 44Annex D (informative) Guidance on the basis for selection of the test load 46BS EN 1363-1:2012EN 1363-1:2012 (E) 4 D.1 General . 46D.2 Options for selecting the test load 46Annex E (informative) Boundary and support condit

21、ions . 47Annex F (informative) Guidance on conditioning . 48F.1 General . 48F.2 Guidance on procedures for conditioning . 48F.3 Guidance on measurement techniques . 49F.3.1 Direct reading moisture meter . 49F.3.2 Oven drying techniques . 49Annex G (informative) Guidance on deflection measurements of

22、 vertical separating elements using a fixed datum 50G.1 General . 50G.2 Apparatus 50G.3 Procedure 50G.4 Reporting . 51Bibliography . 52BS EN 1363-1:2012EN 1363-1:2012 (E) 5 Foreword This document (EN 1363-1:2012) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the sec

23、retariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2013, and conflicting national standards shall be withdrawn at the latest by January 2013. Attention is dr

24、awn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1363-1:1999. The main changes compared to EN 1363-1:1999 are: a) a tolera

25、nce is specified for the thickness of the thermocouple wire in the furnace thermocouple; b) a small variation to the layout of the unexposed surface thermocouples; c) a tolerance to the maximum pressure is specified; d) a redefinition of standard supporting constructions; e) a change to the required

26、 distance of thermocouples to a discontinuity from 15 mm into 20 mm; f) a redefinition of the commencement of the fire test; g) a redefinition for the load bearing capacity criterion; h) specifications for the short form test report are removed. This document has been prepared under a mandate given

27、to CEN by the European Commission and the European Free Trade Association. This European Standard is technically related to ISO 834-1 prepared by ISO/TC92/SC2 “Fire resistance tests“. EN 1363, Fire resistance tests, consists of the following parts: Part 1: General requirements (this European Standar

28、d); Part 2: Alternative and additional procedures; Part 3: Verification of furnace performance (published as an ENV). According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bu

29、lgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,

30、Turkey and the United Kingdom. BS EN 1363-1:2012EN 1363-1:2012 (E) 6 Introduction The objective of determining fire resistance is to assess the behaviour of a specimen of an element of building construction when subjected to defined heating and pressure conditions. The method provides a means of qua

31、ntifying the ability of an element to withstand exposure to high temperatures. It does so by setting criteria against which the loadbearing capacity, the fire containment (integrity) and the thermal transmittance (insulation) functions amongst other characteristics can be evaluated. A representative

32、 sample of the element is exposed to a specified regime of heating and the performance of the test specimen is monitored on the basis of criteria described in the standard. Fire resistance of the test element is expressed as the time for which the appropriate criteria have been satisfied. The times

33、so obtained are a measure of the adequacy of the construction in a fire; but they have no direct relationship with the duration time of a real fire. Caution The attention of all persons concerned with managing and carrying out fire resistance testing is drawn to the fact that fire testing might be h

34、azardous and that there is a possibility that toxic and/or harmful smoke and gases will be emitted during the test. Mechanical and operational hazards might also arise during the construction of the test elements or structures, their testing and disposal of test residues. An assessment of all potent

35、ial hazards and risks to health needs to be made and safety precautions need to be identified and provided. Written safety instructions will be issued. Appropriate training will be given to relevant personnel. Laboratory personnel will ensure that they follow written safety instructions at all times

36、. Uncertainty of measurement of fire resistance There are many factors which can affect the result of a fire resistance test. Those concerned with the variability of the specimen including its materials, manufacture and installation are not related to the uncertainty of measurement. Of the remainder

37、, some, such as the different thermal dose provided by different furnaces, are much more significant than others such as the accuracy of calibration of the data logging system. Because of the very labour intensive nature of the test, many of the factors that have a bearing on the result are operator

38、-dependent. The training, experience and attitude of the operator is thus crucial to eliminate such variables which can significantly affect the degree of uncertainty of measurement. Unfortunately, it is not possible to numerically quantify these factors and therefore any attempt to determine uncert

39、ainty of measurement that does not take into account operator-dependent variables is of limited value. BS EN 1363-1:2012EN 1363-1:2012 (E) 7 1 Scope This European Standard establishes the general principles for determining the fire resistance of various elements of construction when subjected to sta

40、ndard fire exposure conditions. Alternative and additional procedures to meet special requirements are given in EN 1363-2. The principle that has been embodied within all European Standards relating to fire resistance testing is that where aspects and procedures of testing are common to all specific

41、 test methods e.g. the temperature/time curve, then they are specified in this test method. Where a general principle is common to many specific test methods but the details vary according to the element being tested (e.g. the measurement of unexposed face temperature), then the principle is given i

42、n this document, but the details are given in the specific test method. Where certain aspects of testing are unique to a particular specific test method (e.g. the air leakage test for fire dampers), then no details are included in this document. The test results obtained might be directly applicable

43、 to other similar elements, or variations of the element tested. The extent to which this application is permitted depends upon the field of direct application of the test result. This is restricted by the provision of rules which limit the variation from the tested specimen without further evaluati

44、on. The rules for determining the permitted variations are given in each specific test method. Variations outside those permitted by direct application are covered under extended application of test results. This results from an in-depth review of the design and performance of a particular product i

45、n test(s) by a recognised authority. Further consideration on direct and extended application is given in Annex A. The duration for which the tested element, as modified by its direct or extended field of application, satisfies specific criteria will permit subsequent classification. All values give

46、n in this Standard are nominal unless otherwise specified. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the lat

47、est edition of the referenced document (including any amendments) applies. EN 520, Gypsum plasterboards Definitions, requirements and test methods EN 1363-2, Fire resistance tests Part 2: Alternative and additional procedures EN 13501-1, Fire classification of construction products and building elem

48、ents Part 1: Classification using data from reaction to fire tests EN ISO 13943:2010, Fire safety Vocabulary (ISO 13943:2008) EN 60584-1, Thermocouples Part 1: Reference tables (IEC 60584-1) EN 60584-2, Thermocouples Part 2: Tolerances (IEC 60584-2) BS EN 1363-1:2012EN 1363-1:2012 (E) 8 3 Terms, def

49、initions, symbols and designations 3.1 Terms and definitions For the purposes of document, the terms and definitions given in EN ISO 13943:2010 and the following apply. 3.1.1 actual material properties properties of a material determined from representative samples taken from the test specimen for the fire test according to the re