EN 1366-3-2009 en Fire resistance tests for service installations - Part 3 Penetration seals《服务设施的防火试验 第3部分 渗透密封件》.pdf

上传人:feelhesitate105 文档编号:708141 上传时间:2019-01-03 格式:PDF 页数:108 大小:1.60MB
下载 相关 举报
EN 1366-3-2009 en Fire resistance tests for service installations - Part 3 Penetration seals《服务设施的防火试验 第3部分 渗透密封件》.pdf_第1页
第1页 / 共108页
EN 1366-3-2009 en Fire resistance tests for service installations - Part 3 Penetration seals《服务设施的防火试验 第3部分 渗透密封件》.pdf_第2页
第2页 / 共108页
EN 1366-3-2009 en Fire resistance tests for service installations - Part 3 Penetration seals《服务设施的防火试验 第3部分 渗透密封件》.pdf_第3页
第3页 / 共108页
EN 1366-3-2009 en Fire resistance tests for service installations - Part 3 Penetration seals《服务设施的防火试验 第3部分 渗透密封件》.pdf_第4页
第4页 / 共108页
EN 1366-3-2009 en Fire resistance tests for service installations - Part 3 Penetration seals《服务设施的防火试验 第3部分 渗透密封件》.pdf_第5页
第5页 / 共108页
点击查看更多>>
资源描述

1、BS EN 1366-3:2009ICS 13.220.50NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFire resistance tests for service installationsPart 3: Penetration sealsIncorporating corrigendum November 2009This British Standard was published under the authority of the Standards

2、Policy and Strategy Committee on 31 March 2009 BSI 2009ISBN 978 0 580 69607 7Amendments/corrigenda issued since publicationDate CommentsBS EN 1366-3:2009National forewordThis British Standard is the UK implementation of EN 1366-3:2009. Itsupersedes BS EN 1366-3:2004 which is withdrawn.The UK partici

3、pation in its preparation was entrusted to TechnicalCommittee FSH/22/3, Test procedures for fire penetration and seals.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contra

4、ct. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunityfrom legal obligations.30 November 2009 Replacement of core text with CEN corrected versionEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 1366-3February 2009ICS 13.220.50 Supersedes EN

5、1366-3:2004 English VersionFire resistance tests for service installations - Part 3: PenetrationsealsEssais de rsistance au feu des installations techniques -Partie 3 : Calfeutrements de trmiesFeuerwiderstandsprfungen fr Installationen - Teil 3:AbschottungenThis European Standard was approved by CEN

6、 on 3 January 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may

7、 be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN

8、Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, N

9、orway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form an

10、d by any means reservedworldwide for CEN national Members.Ref. No. EN 1366-3:2009: EEN 1366:2009 (E) 2 Contents Page Foreword . 4Introduction 51 Scope 62 Normative references . 63 Terms and definitions . 84 Test equipment 115 Test conditions 115.1 Heating conditions 115.2 Pressure conditions 116 Tes

11、t specimen . 126.1 Size and distances 126.2 Number . 126.3 Design 126.4 Construction 156.5 Verification . 157 Installation of test specimen 157.1 General . 157.2 Supporting construction 157.3 Installation of service(s) . 177.4 Installation of penetration seal 177.5 Multiple penetration seals in one

12、test specimen . 178 Conditioning 179 Application of instrumentation 179.1 Thermocouples . 179.2 Integrity measurement 199.3 Pressure . 1910 Test procedure 1910.1 General . 1910.2 Integrity 1910.3 Other observations . 1911 Performance criteria . 2011.1 Integrity 2011.2 Insulation . 2011.3 Multiple pe

13、netrations 2012 Test report . 2013 Field of direct application of test results 2013.1 Orientation . 2013.2 Supporting construction 2113.3 Services . 2113.4 Service support construction 2213.5 Seal size and distances 22Annex A (normative) Standard configuration for large cable penetration seals . 26A

14、.1 Structure of specimens 26A.2 Non-standard configuration . 28BS EN 1366-3:2009EN 1366-3:2009 (E) 3 A.3 Field of direct application 28Annex B (normative) Standard configuration for small cable penetration seals 42B.1 Structure of specimens 42B.2 Field of direct application 43B.3 Non-standard config

15、uration . 44Annex C (normative) Standard configuration and field of direct application for modular systems and cable boxes . 49C.1 Modular Systems 49C.2 Cable boxes . 51C.3 Non-standard configuration . 52Annex D (normative) Specimen design and field of direct application for bus bars 56D.1 Structure

16、 of specimens 56D.2 Field of direct application 56D.3 Non-standard configuration . 56Annex E (normative) Standard configuration and field of direct application for pipe penetration seals . 58E.1 Standard configuration for penetration seals for pipes according to 6.3.2 a) “metal pipes“ . 58E.2 Standa

17、rd configuration for penetration seals for pipes according to 6.3.2 d) “plastic pipes“ . 61E.3 Trunking and conduits . 65E.4 Standard configuration for floor penetrations ending at floor level (e.g. floor drain) . 66Annex F (normative) Standard configuration and field of direct application for large

18、 mixed penetration seals . 74F.1 General . 74F.2 Standard Mixed Module 74F.3 Standard configuration for combinations of type a) according to F.1.2 . 76F.4 Standard configuration for combinations of type b), c) and d) according to F.1.2 76F.5 Field of direct application 77Annex G (normative) Critical

19、 pipe/cable approach . 84G.1 General . 84G.2 Definition of “critical“ . 84G.3 Procedure selecting critical pipes from previous test data 84G.4 Procedure selecting critical cables from previous test data 85Annex H (informative) Explanatory notes 87H.1 General . 87H.2 Notes on the scope and applicatio

20、n of test results . 87H.3 Notes on test conditions 92H.4 Notes on test construction 92H.5 Notes on test procedure . 102H.6 Notes on test criteria 102H.7 Notes on validity of test results (field of application) . 102H.8 Notes on test report 103Bibliography . 104BS EN 1366-3:2009EN 1366:2009 (E) 4 For

21、eword This document (EN 1366:2009) has been prepared by Technical Committee CEN/TC 127 “”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2009, and

22、 conflicting national standards shall be withdrawn at the latest by August 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This

23、document supersedes EN 1366-3:2004. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. Annexes A to G are normative. Annex H is informative. EN 1366, Fire resistance tests for service installations consists of the followin

24、g: Part 1: Ducts Part 2: Fire dampers Part 3: Penetration seals Part 4: Linear joint seals Part 5: Service ducts and shafts Part 6: Raised access floors and hollow floors Part 7: Conveyors systems and their closures Part 8: Smoke extraction ducts Part 9: Single compartment smoke extraction ducts Par

25、t 10: Smoke control dampers (in course of preparation) Part 11: Protective systems for essential services (in course of preparation) According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austr

26、ia, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 1366

27、-3:2009EN 1366-3:2009 (E) 5 Introduction This part of this European Standard has been prepared to provide a method of test for assessing the contribution of a penetration seal to the fire resistance of separating elements when they have been penetrated by a service or services. CAUTION The attention

28、 of all persons concerned with managing and carrying out this fire resistance test is drawn to the fact that fire testing may be hazardous and that there is a possibility that toxic and/or harmful smoke and gases may be evolved during the test. Mechanical and operational hazards may also arise durin

29、g the construction of the test elements or structures, their testing and disposal of test residues. An assessment of all potential hazards and risks to health should be made and safety precautions should be identified and provided. Written safety instructions should be issued. Appropriate training s

30、hould be given to relevant personnel. Laboratory personnel should ensure that they follow written safety instructions at all times. BS EN 1366-3:2009EN 1366:2009 (E) 6 1 Scope This Part of EN 1366 specifies a method of test and criteria for the evaluation (including field of application rules) of th

31、e ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service. Penetration seals used to seal gaps around chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke

32、 extraction ducts are excluded from this standard except for mixed penetration seals. The fire resistance of those services itself cannot be assessed with the methods described in this standard. Supporting constructions are used in this standard to represent separating elements such as walls or floo

33、rs. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice. This European Standard is used in conjunction with EN 1363-1. The purpose of this test described in this standard is to assess: a) the effect of such

34、penetrations on the integrity and insulation performance of the separating element concerned; b) the integrity and insulation performance of the penetration seal; c) the insulation performance of the penetrating service or services, and where necessary, the integrity failure of a service. No informa

35、tion can be implied by the test concerning the influence of the inclusion of such penetrations and sealing systems on the loadbearing capacity of the separating element. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on th

36、e transmission or generation of fumes. Such phenomena are only to be noted in describing the general behaviour of test specimens during the test. This test is not intended to supply any information on the ability of the penetration seal to withstand stress caused by movements or displacements of the

37、 penetrating services. The risk of spread of fire downwards caused by burning material, which drips through a pipe downwards to floors below, cannot be assessed with this test. Explanatory notes to this test method are given in Annex H. All dimensions given without tolerances are nominal ones unless

38、 otherwise stated. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 520,

39、 Gypsum plasterboards Definitions, requirements and test methods EN 1329-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure Unplasticized poly(vinyl chloride) (PVC-U) Part 1: Specifications for pipes, fittings and the system EN 1363-1:199

40、9, Fire resistance tests Part 1: General requirements BS EN 1366-3:2009EN 1366-3:2009 (E) 7 EN 1363-2, Fire resistance tests Part 2: Alternative and additional procedures EN 1452-1, Plastics piping systems for water supply Unplasticized poly(vinyl chloride) (PVC-U) Part 1: General EN 1453-1, Plastic

41、s piping systems with structured wall-pipes for soil and waste discharge (low and high temperature) inside buildings Unplasticized poly(vinyl chloride) (PVC-U) Part 1: Specifications for pipes and the system EN 1455-1, Plastics piping systems for soil and waste discharge (low and high temperature) w

42、ithin the building structure Acrylonitrile-butadiene-styrene (ABS) Part 1: Requirements for pipes, fittings and the system EN 1519-1, Plastics piping systems for soil and waste discharge (low and high temperature) within the building structure Polyethylene (PE) Part 1: Specifications for pipes, fitt

43、ings and the system EN 1565-1, Plastics piping systems with structured-wall pipes for soil and waste discharge (low and high temperature) inside buildings Styrene copolymer blends (SAN+PVC) Part 1: Specifications for pipes, fittings and the system EN 1566-1, Plastics piping systems for soil and wast

44、e discharge (low and high temperature) within the building structure Chlorinated poly(vinyl chloride) (PVC-C) Part 1: Specifications for pipes, fittings and the system EN 1992-1-2, Eurocode 2 Design of concrete structures Part 1-2: General rules Structural fire design EN 1996-1-2, Eurocode 6 Design

45、of masonry structures Part 1-2: General rules Structural fire design EN 10305-4, Steel tubes for precision applications Technical delivery conditions Part 4: Seamless cold drawn tubes for hydraulic and pneumatic power systems EN 10305-6, Steel tubes for precision applications Technical delivery cond

46、itions Part 6: Welded cold drawn tubes for hydraulic and pneumatic power systems EN 12201-2, Plastics piping systems for water supply Polyethylene (PE) - Part 2: Pipes EN 12449, Copper and copper alloys Seamless, round tubes for general purposes EN 12666-1, Plastics piping systems for non-pressure u

47、nderground drainage and sewerage Polyethylene (PE) Part 1: Specifications for pipes, fittings and the system EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using test data from reaction to fire tests EN 13501-2, Fire classification of constructi

48、on products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services EN 13600, Copper and copper alloys Seamless copper tubes for electrical purposes EN ISO 13943:2000, Fire safety Vocabulary (ISO 13943:2000) EN 61386-21, Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems (IEC 61386-21:2002) HD 21.3, Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V Part 3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1