1、BS EN 1401-1:2009ICS 23.040.20; 93.030NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDPlastic piping systems for non-pressure underground drainageand sewerage Unplasticized poly(vinyl chloride) (PVC-U)Part 1: Specifications for pipes, fittings and the systemInco
2、rporating corrigendumOctober 2009 BS EN 1401-1:2009This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2009 BSI 2009ISBN 978 0 580 68805 8National forewordThis British Standard is the UK implementation of EN 1401-1:2009. It supersedes BS
3、EN 1401-1:1998 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee PRI/88, Plastics piping systems and components, to Subcom-mittee PRI/88/1, Thermoplastics piping systems and components for non-pressure applications.A list of organizations represented on
4、 this subcommittee can be obtained on request to its secretary.The responsible UK technical committee offers the following information in respect of the contents of this standard.1. Selection and application of stiffness classesBS EN 1401-1:2009 specifies three classes of pipes and fittings of diffe
5、ring stiffness, designated SN 2, SN 4 and SN 8 (see Table 4 and Table 6).From the viewpoint of installation, the SN 8 or SN 4 classes have to be used if the system is to be installed in accordance with BS EN 1610 or BS 5955-6, in order to achieve the intended resistance to long-term deformation.If i
6、t is intended to use the other, less stiff (SN 2), class of pipe or fitting, the installation should first be subject to a structural design soil load calculation and the installation technique modified to suit the results of that calculation. The appropriate calculation method is given in the Natio
7、nal Annex for BS EN 1295-1. The E modulus for the material should be taken as 3,000 MPa and 1,500 MPa for the short-term and long-term values respectively.Amendments/corrigenda issued since publicationDate Comments 31 October 2009 National foreword revisedReference material and further guidance on p
8、rocedures for selecting materials for sewers and pumping mains can be found in Materials selection manual for sewers, pumping mains and manholes (reference WSA/FWR-04)1Additional informationFor swept bends and branches, the dimensional characteristics should also conform to the relevant parts of BS
9、4514 and in addition the Building Regulations 2000 (amended 2002) Approved Document H1 (Diagram 2 and Clauses 1.17 and 1.26). When pipe conforming to EN 1401 is perforated for drainage applications, the perforations should additionally meet the requirements for UPVC in accordance with BS 4660, given
10、 in the DETR Manual of Contract Documents for Highway Works (Volume 1) Specification for Highway Works Series 500.This British Standard does not necessarily detail all the precautions necessary to meet the requirements of the Health and Safety at Work etc Act 1974. Attention should be paid to any ap
11、propriate safety precautions and the test methods in this standard should be operated only by trained personnel.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer
12、immunity from legal obligations.1Published by the Foundation for Water Research, Allen House, The Listons, Liston Road, Marlow, Bucks SL7 1FDBS EN 1401-1:2009iThis page deliberately set blankBS EN 1401-1:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 1401-1March 2009ICS 93.030 Supersedes EN 1
13、401-1:1998 English VersionPlastics piping systems for non-pressure underground drainageand sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part1: Specifications for pipes, fittings and the systemSystmes de canalisations en plastique pour lesbranchements et les collecteurs dassainissement ent
14、errssans pression - Poly(chlorure de vinyle) non plastifi (PVC-U) - Partie 1 : Spcifications pour tubes, raccords et lesystmeKunststoff-Rohrleitungssysteme fr erdverlegte druckloseAbwasserkanle und-leitungen - WeichmacherfreiesPolyvinylchlorid (PVC-U) - Teil 1: Anforderungen an Rohre,Formstcke und d
15、as RohrleitungssystemThis European Standard was approved by CEN on 10 January 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and
16、bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibilit
17、y of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Irel
18、and, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-
19、1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1401-1:2009: EEN 1401-1:2009 (E) 2 Contents Page Foreword 4 1 Scope 6 2 Normative references . 6 3 Terms, definitions, symbols and abbreviations 7 3.1 Terms and defin
20、itions . 7 3.2 Symbols . 9 3.3 Abbreviations . 10 4 Material . 10 4.1 Raw material 10 4.2 Pipe material 11 4.3 Fitting material 11 4.4 Utilisation of non-virgin materials . 12 4.5 Sealing ring retaining means . 12 5 General characteristics 12 5.1 Appearance 12 5.2 Colour . 12 6 Geometrical character
21、istics . 12 6.1 General 12 6.2 Dimensions of pipes . 12 6.3 Dimensions of fittings . 15 6.4 Dimensions of sockets and spigots 16 6.5 Types of fittings 20 7 Mechanical characteristics 23 7.1 Mechanical characteristics of pipes . 23 7.2 Mechanical characteristics of fittings . 24 8 Physical characteri
22、stics . 24 8.1 Physical characteristics of pipes 24 8.2 Physical characteristics of fittings 25 9 Performance requirements 26 10 Sealing rings 27 11 Adhesives 27 12 Marking. 27 12.1 General 27 12.2 Minimum required marking of pipes . 28 12.3 Minimum required marking of fittings . 29 12.4 Additional
23、marking . 29 Annex A (normative) Utilisation of non-virgin material . 30 A.1 Material definitions . 30 A.2 Own reprocessable material 30 A.3 External reprocessable and recyclable materials with agreed specification . 31 A.4 External reprocessable and recyclable materials not covered by an agreed spe
24、cification . 33 BS EN 1401-1:2009EN 1401-1:2009 (E) 3 A.5 Summary of use of non-virgin material . 33 Annex B (informative) General characteristics of PVC-U pipes and fittings . 34 B.1 General . 34 B.2 Compound characteristics 34 B.3 Ring stiffness 34 B.4 Creep ratio 34 B.5 Chemical resistance . 35 B
25、.6 Abrasion resistance 35 B.7 Hydraulic roughness . 35 B.8 Diametric deflection 35 Annex C (informative) Product standards . 36 Bibliography . 37 BS EN 1401-1:2009EN 1401-1:2009 (E) 4 Foreword This document (EN 1401-1:2009) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems
26、 and ducting systems”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2009, and conflicting national standards shall be withdrawn at the latest
27、by September 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1401-1:1998. The main changes with resp
28、ect to the previous edition are listed below: a) addition of a definition for solid wall pipes and fittings (3.1.13); b) updating of the references in Clause 2, Annex C and Bibliography; c) raw material (4.1); d) Cmaxof sockets (Table 5); e) the SN series is extended with the sizes DN 710 (non-prefe
29、rred) and DN 800 (Table 4); f) O-ring type sockets (6.4); g) solvent cement sockets (6.4.2.1); h) additional mechanical requirements of pipes (7.1.2); i) physical characteristics of pipes (Table 12 and note); j) performance requirements (Table 15 first row); k) deletion of Long Term Performance of T
30、PE seals (Table 15 and 10.3); l) reformulated material (A.1.5 and A.3.3); m) reprocessable and recyclable material from PVC-U products other than pipes and fittings (A.3.2 and Table A.2); n) summary of use of non-virgin material (A.5, Table A.3); o) compound characteristics (B.2). This European Stan
31、dard is a Part of a System Standard for plastics piping systems of a particular material for a specified application. There are a number of such System Standards. System Standards are based on the results of the work undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of
32、fluids“, which is a Technical Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test methods to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirem
33、ents and on recommended practice for installation. EN 1401 consists of the following Parts, under the general title Plastics piping systems for non-pressure underground drainage and sewerage Unplasticized poly(vinyl chloride) (PVC-U) Part 1: Specifications for pipes, fittings and the system (the pre
34、sent standard) Part 2: Guidance for assessment of conformity (under revision) BS EN 1401-1:2009EN 1401-1:2009 (E) 5 Part 3: Guidance for installation (ENV) According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this E
35、uropean Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the Uni
36、ted Kingdom. BS EN 1401-1:2009EN 1401-1:2009 (E) 6 1 Scope This Part of EN 1401 specifies the requirements for solid wall pipes, fittings and the system of unplasticized poly(vinyl chloride) (PVC-U) piping systems in the field of non-pressure underground drainage and sewerage: a) outside the buildin
37、g structure (application area code “U“) and b) both buried in ground within the building structure (application area code “D“) and outside the building. This is reflected in the marking of products by “U“ and “UD“. It also specifies the test parameters for the test methods referred to in this Europe
38、an Standard. This European Standard covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects,
39、 taking into account their particular requirements and any relevant national regulations and installation practices or codes. In conjunction with prCEN/TS 1401-2 1 and ENV 1401-3 2 it is applicable to PVC-U pipes and fittings, their joints and to joints with components of other plastics and non-plas
40、tics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage. This European Standard is applicable to non foamed PVC-U pipes without a socket as well as pipes with an integral socket. The fittings can be manufactured by injection-moulding or be fabr
41、icated from pipes and/or mouldings. Requirements and limiting values for application area code “D“ are given in Table 4, Table 6, Table 13 and Table 15. NOTE 2 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittin
42、gs conforming to this European Standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 15. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only
43、the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 580, Plastics piping systems Unplasticized poly(vinyl chloride)(PVC-U) pipes Test method for the resistance to dichloromethane at a specified temperature (DCMT) EN
44、681-1, Elastomeric seals Materials requirements for pipe joint seals used in water and drainage applications Part 1: Vulcanized rubber EN 681-2, Elastomeric seals Materials requirements for pipe joint seals used in water and drainage applications Part 2: Thermoplastic elastomers EN 727, Plastics pip
45、ing and ducting systems Thermoplastics pipes and fittings Determination of Vicat softening temperature (VST) EN 744:1995, Plastics piping and ducting systems Thermoplastics pipes Test method for resistance to external blows by the round-the-clock method BS EN 1401-1:2009EN 1401-1:2009 (E) 7 EN 922,
46、Plastics piping and ducting systems Pipes and fittings of unplasticized poly(vinyl chloride) (PVC-U) Specimen preparation for determination of the viscosity number and calculation of the K-value EN 1053, Plastics piping systems Thermoplastics piping systems for non-pressure applications Test method
47、for watertightness EN 1055, Plastics piping systems Thermoplastics piping systems for soil and waste discharge inside buildings Test method for resistance to elevated temperature cycling EN 1277, Plastics piping systems Thermoplastics piping systems for buried non-pressure applications Test method f
48、or leaktightness of elastomeric sealing ring type joints EN 1411:1996, Plastics piping and ducting systems Thermoplastics pipes Determination of resistance to external blows by the staircase method EN 1905, Plastics piping systems Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and materi
49、al Method for assessment of the PVC content based on total chlorine content EN 10204:2004, Metallic products Types of inspection documents EN 12061, Plastics piping systems Thermoplastics fittings Test method for impact resistance EN 12256, Plastics piping systems Thermoplastics fittings Test method for mechanical strength or flexibility of fabricated fittings EN ISO 472:2001, Plastics Vocabulary (ISO 472:1999) EN ISO 580, Plastics piping and ducting systems Injection-moulded thermoplastics fittings