EN 14177-2003 en Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid liquid partition clean-up《食品 澄清和浑浊苹果汁和果泥中棒曲霉素的测定 液体 液体分溶提纯的高效.pdf

上传人:吴艺期 文档编号:708773 上传时间:2019-01-03 格式:PDF 页数:18 大小:185.97KB
下载 相关 举报
EN 14177-2003 en Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid liquid partition clean-up《食品 澄清和浑浊苹果汁和果泥中棒曲霉素的测定 液体 液体分溶提纯的高效.pdf_第1页
第1页 / 共18页
EN 14177-2003 en Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid liquid partition clean-up《食品 澄清和浑浊苹果汁和果泥中棒曲霉素的测定 液体 液体分溶提纯的高效.pdf_第2页
第2页 / 共18页
EN 14177-2003 en Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid liquid partition clean-up《食品 澄清和浑浊苹果汁和果泥中棒曲霉素的测定 液体 液体分溶提纯的高效.pdf_第3页
第3页 / 共18页
EN 14177-2003 en Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid liquid partition clean-up《食品 澄清和浑浊苹果汁和果泥中棒曲霉素的测定 液体 液体分溶提纯的高效.pdf_第4页
第4页 / 共18页
EN 14177-2003 en Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid liquid partition clean-up《食品 澄清和浑浊苹果汁和果泥中棒曲霉素的测定 液体 液体分溶提纯的高效.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 14177:2003 Foodstuffs Determination of patulin in clear and cloudy apple juice and puree HPLC method with liquid/liquid partition clean-up The European Standard EN 14177:2003 has the status of a British Standard ICS 67.080.10; 67.160.20 BS EN 14177:2003 This British Standard w

2、as published under the authority of the Standards Policy and Strategy Committee on 13 January 2004 BSI 13 January 2004 ISBN 0 580 43217 3 National foreword This British Standard is the official English language version of EN 14177:2003. The UK participation in its preparation was entrusted to Techni

3、cal Committee AW/-/3, Horizontal analysis, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document ma

4、y be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users

5、are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, a

6、nd keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 15 and a back cover. The BSI copyright notice displayed in this docum

7、ent indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN14177 December2003 ICS67.080.10;67.160.20 Englishversion FoodstuffsDeterminationofpatulininclearandcloudyapple juiceandpureeHPLCmethodwithliquid

8、/liquidpartitionclean up ProduitsalimentairesDterminationdelateneuren patulinedanslejusdepommesetdanslacompotede pommes,limpidesettroublesMthodepar chromatographieenphaseliquidehauteperformance avecpurificationparpartageliquide/liquide LebensmittelBestimmungvonPatulininklaremund trbemApfelsaftundApf

9、elpreeHPLCVerfahrenmit ReinigungdurchFlssig/FlssigVerteilung ThisEuropeanStandardwasapprovedbyCENon3November2003. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsand

10、bibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheManagementCentreortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnoti

11、fiedtotheManagementCentrehasthesamestatusasthe official versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,France,Germany,Greece, Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal,Slovakia,Spain,Sweden,SwitzerlandandUn ited Kingd

12、om. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2003CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN14177:2003EEN14177:2003(E) 2 Contents Page Foreword. 4

13、 1 Scope . 5 2 Normativereferences . 5 3 Principle. 5 4 Reagents 5 4.1 General. 5 4.2 Sodiumcarbonatesolution,massconcentration rr (Na 2 CO 3 ) 15g/l 5 4.3 Aceticacid,volumeconcentration jj (CH 3 COOH) 98% 5 4.4 Sodiumsulfateanhydrous . 5 4.5 pH4water 5 4.6 Absoluteethanol, jj (CH 3 CH 2 OH) 99,7%.

14、6 4.7 Ethylacetate. . 6 4.8 Perchloricacid, jj (HClO 4 )=60%. 6 4.9 Acetonitrile 6 4.10 Endogalacturonaseenzymesolution,typicalactivity1400U/g . 6 4.11 HPLCmobilephase 6 4.12 Patulinstocksolution. 6 4.13 Patulinstandardsolution . 6 4.14 Patulinstandardsolutionforcalibration 7 5 Apparatus 7 5.1 Gener

15、al. 7 5.2 Displacementpipettesof5ml,1ml,200 m land50 m lcapacitywithappropriatepipette tips 7 5.3 Analyticalbalance . 7 5.4 UVspectrophotometer,doublebeamandrecordingsuitableformeasurementat250nm to350nm . 7 5.5 Quartzcells,ofopticalpathlength1cm. . 7 5.6 Centrifuge,capableofoperatingat4500 g . 7 5.

16、7 Centrifugetubesof50mlcapacitywithscrewcaplids . 7 5.8 Rotaryevaporator,withwaterbathsetat40C . . 7 5.9 Filterpaper,withporesize20mto25m . 7 5.10 Disposablesyringefilters,of0,2 m mporesize(optional) 7 5.11 HPLCapparatus,comprisingthefollowing . 7 5.12 Roundbottomflasks,of250mlcapacitywithgroundglas

17、sjoint. . 8 6 Procedure 8 6.1 Preparationoftestsamples. 8 6.2 Extractionofpatulin . 8 6.3 Removalofinterferingacidiccompounds . 8 6.4 Preparationofthesampletestsolution . 9 7 Spikingprocedure . . 9 7.1 Clearapplejuice. . 9 7.2 Cloudyapplejuice 9 7.3 Applepuree . 9 8 HPLCdetermination . 9 8.1 Calibra

18、tiongraph . . 9 8.2 HPLCoperatingconditions. . 10 9 Calculation. 10EN14177:2003(E) 3 10 Precision.10 10.1 Interlaboratorytest. .10 10.2 Repeatability 11 10.3 Reproducibility.11 10.4 Testreport 12 AnnexA (informative) Precisiondata .13 Bibliography15EN14177:2003(E) 4 Foreword Thisdocument(EN14177:200

19、3)hasbeenpreparedbyTechnicalCommitteeCEN/TC275“Foodanalysis Horizontalmethods”,thesecretariatofwhichisheldbyDIN. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherbypublicationofanidentical textorbyendorsement,atthelatestbyJune2004,andconflictingnationalstandardsshallbewithdrawnat t

20、helatestbyJune2004. AnnexAisinformative. WARNINGTheuseofthisstandardcaninvolvehazardousmaterials,operationsandequipment. Thisstandarddoesnotpurporttoaddressallthesafetyproblemsassociatedwithitsuse.Itisthe responsibilityoftheuserofthisstandardtoestablishappropriatesafetyandhealthpracticesand determin

21、etheapplicabilityofregulatorylimitationspriortouse. AccordingtotheCEN/CENELECInternalRegulations,thenationalstandardsorganizationsofthefollowing countriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,CzechRepublic,Denmark, Finland,France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Luxembo

22、urg,Malta,Netherlands, Norway,Portugal,Slovakia,Spain,Sweden,SwitzerlandandtheUnitedKingdom.EN14177:2003(E) 5 1Scope ThisEuropeanStandardspecifiesamethodforthedeterminationofpatulininapplejuicesandapplepuree usinghighperformanceliquidchromatography(HPLC).Themethodhasbeenvalidatedforthedetermination

23、ofpatulinviatheanalysisofnaturallycontaminatedandspikedsamplesinclearapplejuiceatlevelsranging from26 m g/lupto128 m g/l,incloudyapplejuiceatlevelsrangingfrom26 m g/lupto106 m g/landinapple pureeatlevelsrangingfrom23 m g/kgupto121 m g/kg. 2 Normativereferences ThisEuropeanStandardincorporatesbydated

24、orundatedreference,provisionfromotherpublications.These normativereferencesarecitedattheappropriateplacesinthetextandthepublicationsarelistedhereafter. Fordatedreferences,subsequentamendmentstoorrevisionsofanyofthesepublicationsapplytothis EuropeanStandardonlywhenincorporatedinitbyamendmentorrevisio

25、n.Forundatedreferencesthelatest editionofthepublicationreferredtoapplies(includingamendments). ENISO3696, WaterforanalyticallaboratoryuseSpecificationandtestmethods(ISO3696:1987) 3Principle Cloudyapplejuiceandapplepureearetreatedwithapectinaseenzyme.Patulinisextractedfromapplejuice orenzymetreatedpu

26、reewithethylacetate.Thesolventextractiscleanedupbyliquidliquidextractionwith aqueoussodiumcarbonatesolution.Theethylacetateextractisdriedwithanhydroussodiumsulfate.After evaporationofethylacetate,patulinisquantitativelydeterminedbyhighperformanceliquidchromatography (HPLC)withultraviolet(UV)detectio

27、n. 4Reagents 4.1General Duringtheanalysis,unlessotherwisestated,useonlyreagentsofrecognizedanalyticalgradeandonly distilledwaterorwaterofgrade1asdefinedinENISO3696.SolventsshallbeofqualityforHPLCanalysis. 4.2 Sodiumcarbonatesolution,massconcentration rr (Na 2 CO 3 ) 15g/l Dissolve1,5gofsodiumcarbona

28、tein100mlofwater. 4.3 Aceticacid,volumeconcentration jj (CH 3 COOH) 98% 4.4 Sodiumsulfateanhydrous 4.5 pH4water AdjustwatertopH4withaceticacid.EN14177:2003(E) 6 4.6 Absoluteethanol, jj (CH 3 CH 2 OH) 99,7% 4.7Ethyl acetate 4.8 Perchloricacid, jj (HClO 4 )=60% 4.9Acetonitrile 4.10 Endogalacturonaseen

29、zymesolution,typicalactivity1400U/g Unitdefinitiontheamountofenzymewhichcatalysesthedecreaseinviscosityofa1%pectinsolutionby 20%in5minatapH3,4andat25 C. NOTE Packagevolumesof100mlto200mlarepractical. 4.11 HPLCmobilephase Mix95partspervolumeofwaterwith5partspervolumeofacetonitrile(4.9)and0,095partspe

30、rvolumeof perchloricacid(4.8),anddegas. 4.12 Patulinstocksolution WARNINGPatulinisasuspectmutagenandhasbeenreportedtohaveimmunotoxicandneurotoxic properties. Glovesandsafety glassesshouldbewornatalltimesandallstandardandsample preparationstagesshouldbecarriedoutinafumecupboard. Dissolve5mgofpatulino

31、rthecontentsof1ampoule(ifpatulinhasbeenobtainedasafilm)inethylacetate (4.7).Transferthesolutiontoa25mlvolumetricflaskanddilutevolumewithethylacetatetoproducea solutioncontainingapproximately200 m g/mlofpatulin.Storethestocksolutioninafreezeratlessthan0 C. 4.13 Patulinstandardsolution Evaporate1000 m

32、 lofthestocksolution(4.12)todrynessundernitrogenandthenimmediatelydissolveitin 20mlofethanol(4.6)toobtainamassconcentrationofapproximately10 m g/mlofpatulin. Todeterminetheexactconcentration,recordtheabsorptioncurvebetween250nmand350nmina1cm quartzcellwithethanolasreference.Identifythewavelengthform

33、aximumabsorption.Calculatethemass concentrationofpatulin, r pat ,inmicrogramspermillilitreusingequation1: d e r = 100 max M A pat (1) where: A max istheabsorbancedeterminedatthemaximumoftheabsorptioncurve(here:atapproximately 276nm); M istherelativemolecularmassofpatulin(M=154,12g/mol); e istherelat

34、ivemolarabsorptioncoefficientofpatulininethanol,(here:1460m 2 /mol,asgivenin AOACOfficialMethods,1995,NaturalToxins,Patulin,49.6.01.C(d); d isthepathlengthofthequartzcellincentimetres.EN14177:2003(E) 7 Storethestandardsolutioninafreezeratlessthan0 C.Solutionsstoredthiswayarestablefor2months. Ensuret

35、hestandardsolutionisallowedtoreachroomtemperaturebeforeusetoavoidincorporationofwater bycondensation. 4.14 Patulinstandardsolutionforcalibration Evaporatetodryness500lofthestandardsolution(4.13)oranaliquotwhichisequivalenttoanabsolute amountof5gofpatulin,dissolvein5mlofpH4water(4.5)toobtainamassconc

36、entrationof1 m g/mlof patulin. Thissolutioncanbestoredinarefrigeratorat4 C.Asolutionstoredinthiswayisstableforatleast8weeks. 5Apparatus 5.1 General Usuallaboratoryequipmentand,inparticular,thefollowing: 5.2 Displacementpipettesof5ml,1ml,200 m land50 m lcapacitywithappropriatepipette tips 5.3 Analyti

37、calbalance 5.4 UVspectrophotometer,doublebeamandrecordingsuitableformeasurementat250nm to350nm 5.5 Quartzcells,ofopticalpathlength1cm 5.6 Centrifuge,capableofoperatingat4500 g 5.7 Centrifugetubesof50mlcapacitywithscrewcaplids 5.8 Rotaryevaporator,withwaterbathsetat40C 5.9 Filterpaper,withporesize20m

38、to25m 5.10 Disposablesyringefilters,of0,2 m mporesize(optional) Testeachbatchbeforeusetoensurethatpatulinisnotadsorbedontothefilter. 5.11 HPLCapparatus,comprisingthefollowing 5.11.1 Injectionsystem,avalveinjectionsystemwitha50 m linjectionloop 5.11.2 Pump,isocratic,pulsefree,capableofmaintainingavol

39、umeflowrateof1ml/min 5.11.3 UVdetector,fittedwithananalyticalflowcellandsetat276nm 5.11.4 AnalyticalreversephaseHPLCcolumn,forexampleC 18 octyldecylsilane(ODS)(fullyorsuperend cappedwithacarbonloadingof12%to17%hasbeenfoundsuitable)whichensuresresolutionofpatulin fromallotherpeaks.Themaximumheightofo

40、verlappingpeakshouldersshallbelessthan10%ofthe maximumpeakheight(itcouldbenecessarytoadjustthemobilephaseforsufficientbaselineresolution).A suitableprecolumnshouldbeused.EN14177:2003(E) 8 5.11.5 Datasystem 5.11.6 SwitchingvalveorsecondHPLCpump,optional,toallowwashingofanalyticalcolumnbetween injecti

41、ons 5.12 Roundbottomflasks,of250mlcapacitywithgroundglassjoint 6Procedure 6.1 Preparationoftestsamples 6.1.1 Clearapplejuice Nopreparationisrequired.Proceedasdescribedin6.2to6.4. 6.1.2Cloudy apple juice Transfer20ml+0,1mlofcloudyjuicetoacentrifugetube(5.7)andadd150 m lofenzymesolution(4.10). Coverwi

42、ththescrewcapandshakewelltomix.Leaveovernightatroomtemperatureorfor2hat40C,after whichcentrifugeat4500 gfor5min. 6.1.3Apple puree Weigh,tothenearest0,1g,a10gtestportionofthepureeintoacentrifugetube(5.7),add150 m lofenzyme solution(4.10)followedby10mlofwater.Coverwiththescrewcapandshakewell,withhomog

43、enizer dependingonthesample,tomix.Leaveovernightatroomtemperatureorfor2hat40C,afterwhich centrifugeat4500 gfor5min. 6.2 Extractionofpatulin Pipette10mlofclearjuiceorcloudyjuiceaspreparedin6.1.2intoa100mlseparatingfunnel.Forapple pureepipette10mlofapplepureeaspreparedin6.1.3intoa100mlseparatingfunnel.Thisisequivalentto 5gapplepuree.Add20mlofethylacetate(4.7)andshakefor1min.Allowthelayerstoseparatethendrain themintotwoseparateconicalflasks.Transfertheaqueousla

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1