EN 1634-1-2014 en Fire resistance and smoke control tests for door and shutter assemblies openable windows and elements of building hardware - Part 1 Fire resistance test for door .pdf

上传人:twoload295 文档编号:709150 上传时间:2019-01-02 格式:PDF 页数:78 大小:3.81MB
下载 相关 举报
EN 1634-1-2014 en Fire resistance and smoke control tests for door and shutter assemblies openable windows and elements of building hardware - Part 1 Fire resistance test for door .pdf_第1页
第1页 / 共78页
EN 1634-1-2014 en Fire resistance and smoke control tests for door and shutter assemblies openable windows and elements of building hardware - Part 1 Fire resistance test for door .pdf_第2页
第2页 / 共78页
EN 1634-1-2014 en Fire resistance and smoke control tests for door and shutter assemblies openable windows and elements of building hardware - Part 1 Fire resistance test for door .pdf_第3页
第3页 / 共78页
EN 1634-1-2014 en Fire resistance and smoke control tests for door and shutter assemblies openable windows and elements of building hardware - Part 1 Fire resistance test for door .pdf_第4页
第4页 / 共78页
EN 1634-1-2014 en Fire resistance and smoke control tests for door and shutter assemblies openable windows and elements of building hardware - Part 1 Fire resistance test for door .pdf_第5页
第5页 / 共78页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 1634-1:2014Fire resistance and smokecontrol tests for door andshutter assemblies, openablewindows and elements ofbuilding hardwarePart 1: Fire resistance test for door andshutter assemblies and openable windowsBS EN 1634-1:2014 BRITISH STANDARDNational forewordThis Bri

2、tish Standard is the UK implementation of EN 1634-1:2014. Itsupersedes BS EN 1634-1:2008 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee FSH/22/-/5, Fire resistance tests for doors.A list of organizations represented on this committee can beobtained on

3、request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 77466 9ICS 13.220.50; 91.060.50Compliance wi

4、th a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2014.Amendments issued since publicationDate Text affectedBS EN 1634-1:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISC

5、HE NORM EN 1634-1 January 2014 ICS 13.220.50; 91.060.50 Supersedes EN 1634-1:2008English Version Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable win

6、dows Essais de rsistance au feu et dtanchit aux fumes des portes, fermetures, fentres et lments de quincailleries - Partie 1: Essais de rsistance au feu des portes, fermetures et fentres Feuerwiderstandsprfungen und Rauchschutzprfungen fr Tren, Tore, Abschlsse, Fenster und Baubeschlge - Teil 1: Feue

7、rwiderstandsprfungen fr Tren, Tore, Abschlsse und Fenster This European Standard was approved by CEN on 29 December 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard witho

8、ut any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other l

9、anguage made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Den

10、mark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTE

11、E FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1634-1:2014 EBS EN 1634-1:201

12、4EN 1634-1:2014 (E) 2 Contents Page Foreword 4 Introduction .5 1 Scope 6 2 Normative references 6 3 Terms and definitions .7 4 Test equipment 8 5 Test conditions 9 6 Test specimen 9 6.1 General 9 6.2 Size 9 6.3 Number .9 6.4 Design .9 6.5 Construction .9 6.6 Verification .9 6.7 Building hardware. 10

13、 7 Installation of test specimen . 10 7.1 General . 10 7.2 Supporting construction 10 7.3 Gaps . 11 8 Conditioning 12 8.1 Moisture content . 12 8.2 Mechanical . 12 9 Application of instrumentation 12 9.1 Thermocouples . 12 9.2 Pressure . 18 9.3 Deflection . 18 9.4 Radiation 18 10 Test procedure 18 1

14、0.1 Pre-test examination and preparation 18 10.2 Fire resistance test . 19 11 Performance criteria . 20 11.1 Integrity 20 11.2 Insulation . 20 11.3 Radiation 20 12 Test report . 21 13 Field of direct application of test results . 22 13.1 General . 22 13.2 Materials and construction 22 13.3 Permissib

15、le size variations 24 13.4 Asymmetrical assemblies 27 13.5 Supporting constructions 29 13.6 Associated supporting constructions 30 BS EN 1634-1:2014EN 1634-1:2014 (E) 3 Annex A (normative) Conditioning requirements 65 A.1 General . 65 A.2 Requirements . 65 Annex B (normative) Field of direct applica

16、tion limits of permitted size variations 66 Annex C (informative) Background to field of direct application statements for asymmetric constructions and supporting constructions. 68 C.1 General . 68 C.2 Hinged doorsets 68 C.3 Pivot hung doorsets 71 C.4 Rolling shutter doorsets . 72 C.5 Sliding/foldin

17、g doorsets . 73 Bibliography 74 BS EN 1634-1:2014EN 1634-1:2014 (E) 4 Foreword This document (EN 1634-1:2014) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standa

18、rd, either by publication of an identical text or by endorsement, at the latest by July 2014, and conflicting national standards shall be withdrawn at the latest by July 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN an

19、d/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1634-1:2008. The following changes have been made since the previous edition (not exhaustive): definitions updated to include Operable fabric curtain; removal of requirement for spon

20、sor declaration on gap values; changes to gap measuring requirements in Clause 7; increased reference to Extended Application; modifications to unexposed face thermocouples in Clause 9; redefined temperature measurement requirements in Clause 11 for the normal procedure; inclusion of openable window

21、s and operable fabric curtains in Direct Application; changes to extended application for gaps in Direct Application; changes to figures. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. EN 1634, “Fire resistance and smo

22、ke control tests for door and shutter assemblies, openable windows and elements of building hardware“ consists of the following parts: Part 1: Fire resistance test for door and shutter assemblies and openable windows (the present document); Part 2: Fire resistance characterisation test for elements

23、of building hardware; Part 3: Smoke control test for door and shutter assemblies. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Repub

24、lic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN

25、 1634-1:2014EN 1634-1:2014 (E) 5 Introduction Caution The attention of all persons concerned with managing and carrying out this fire resistance test is drawn to the fact that fire testing may be hazardous and that there is a possibility that toxic and/or harmful smoke and gases may be evolved durin

26、g the test. Mechanical and operational hazards may also arise during the construction of the test elements or structures, their testing and disposal of test residues. It is imperative that an assessment of all potential hazards and risks to health is made and that safety precautions are identified a

27、nd provided. Written safety instructions need to be issued. Appropriate training should be given to relevant personnel. Laboratory personnel should ensure that they follow written safety instructions at all times. BS EN 1634-1:2014EN 1634-1:2014 (E) 6 1 Scope This European Standard specifies a metho

28、d for determining the fire resistance of door and shutter assemblies and openable windows designed for installation within openings incorporated in vertical separating elements, such as: a) hinged and pivoted doors; b) horizontally sliding and vertically sliding doors including articulated sliding d

29、oors and sectional doors; c) folding doors, sliding folding doors /shutters; d) tilting doors; e) rolling shutter doors; f) openable windows; g) operable fabric curtains. This European Standard is used in conjunction with EN 1363-1. The testing of fire dampers is covered by EN 1366-2. The testing of

30、 closures for conveyor systems is covered by EN 1366-7. By prior agreement with the test sponsor, additional information may be gained for individual elements of building hardware in order to fulfil the performance criteria identified in EN 1634-2. Based on the observations recorded during the test,

31、 the results may be presented in a separate report which should be in accordance with the requirements of EN 1634-2. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only

32、the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1363-1:2012, Fire resistance tests - Part 1: General Requirements EN 1363-2, Fire resistance tests - Part 2: Alternative and additional procedures EN 12519:2004, Wi

33、ndows and pedestrian doors - Terminology EN 13501-2, Fire classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services EN 14600, Doorsets and openable windows with fire resisting and/or smoke control charac

34、teristics - Requirements and classification EN 15269 (all parts), Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware EN ISO 13943:2010, Fire safety - Vocabulary (ISO 13943:2008)

35、 BS EN 1634-1:2014EN 1634-1:2014 (E) 7 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1363-1:2012, EN 12519:2004, EN ISO 13943:2010 and the following apply. 3.1 door or shutter assembly doorset pedestrian doorset or industrial type doorset including

36、any frame or guide, door leaf or leaves, rolling or folding curtain, etc., which is provided to give a fire resisting capability when used for the closing of permanent openings in fire resisting separating elements, which includes any side panel(s), flush over panel(s), transom panel(s) and/or glazi

37、ng together with the building hardware and any seals (whether provided for the purpose of fire resistance or smoke control or for other purposes such as draught or acoustics) which form the assembly 3.2 openable (for windows only) applying to windows with one or more moveable leaf or leaves includin

38、g any side or over panel(s), perimeter frame and any elements of building hardware 3.3 building hardware hinges, handles, locks, exit devices, escutcheons, letter plates, kick plates, sliding gear, closing devices, electrical components, wiring, etc., which are, or can be, used in the doorset 3.4 si

39、ngle action action of a door leaf of a (single or double leaf) doorset which only opens in one direction 3.5 double action action of a door leaf of a (single or double leaf) doorset which opens in both directions 3.6 floor upper surface of the horizontal element on which the doorset is mounted and w

40、hich extends from the exposed face to the unexposed face of the doorset 3.7 sill member which connects two frame jambs together at the base which may or may not be set into the floor and remains visible 3.8 gap clearance between two nominally adjacent surfaces and/or edges (primary gaps are between

41、the edge of the leaf and the reveal of the frame, between the face of the leaf and the frame stop and between adjacent leaves) Note 1 to entry: This does not refer to the integrity failure gap for which the gap gauges are referenced in 10.2.2. 3.9 through component or connection internal spacer or f

42、ixing that either penetrates through the door or shutter construction from one face to another or directly connects the faces one to the other BS EN 1634-1:2014EN 1634-1:2014 (E) 8 3.10 standard supporting construction form of construction used to close off the furnace and to support the doorset or

43、openable window being evaluated and which has a quantifiable influence on both the thermal heat transfer between the construction and the test specimen and provides known resistance to thermal distortion Note 1 to entry: Supporting constructions which are considered to be standard supporting constru

44、ctions are those listed in EN 13631. 3.11 associated supporting construction specific construction in which the doorset or openable window is to be installed in practice and which is used to close off the furnace and provide the levels of restraint and thermal heat transfer to be experienced in norm

45、al use 3.12 test specimen doorset or openable window which is to be installed in a standard or associated supporting construction to allow it to be evaluated 3.13 transom horizontal member fitted between vertical frame members to create an aperture above into which a panel, glazing etc. might be fit

46、ted 3.14 over panel panel which is incorporated within a doorset or openable window and fitted above the leaf or leaves and can be a transom panel or a flush over panel 3.15 transom panel panel which is incorporated within a doorset or openable window and fitted above the leaf or leaves and is bound

47、ed on all edges by the frame head, the jambs and the transom 3.16 flush over panel panel which is incorporated within a doorset or openable window and fitted above the leaf or leaves within the frame head and the jambs and with no transom 3.17 side panel panel which is incorporated within a doorset

48、or openable window and fitted at one side of a leaf and is bounded on all edges by the perimeter frame, the jambs and the transom (when applicable) 3.18 operable fabric curtain doorset with a leaf constructed from woven material combined with other materials in one or more sections Note 1 to entry:

49、The complete assembly includes any frames and/or guides. 4 Test equipment The test equipment specified in EN 1363-1, and if applicable EN 1363-2, shall be used. BS EN 1634-1:2014EN 1634-1:2014 (E) 9 5 Test conditions Appropriate mechanical pre-test conditioning shall be completed in accordance with the requirements in EN 14600. The heating and pressure conditions and the furnace atmosphere shall conform to those given in EN 1363-1 or, if applicable, EN 1363-2 except for openable windows where the pressure at the top of the test speci