1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 1648-2:2012Leisure accommodationvehicles 12 V direct currentextra low voltage electricalinstallationsPart 2: Motor caravansBS EN 1648-2:2012 BRITISH STANDARDNational forewo
2、rdThis British Standard is the UK implementation of EN 1648-2:2012. Itsupersedes BS EN 1648-2:2005 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/511, Buildings mobile and temporary.A list of organizations represented on this committee can beobtained
3、 on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 73872 2ICS 43.040.10; 43.100Compliance w
4、ith a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2012.Amendments issued since publicationDate Text affectedBS EN 1648-2:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE
5、 NORM EN 1648-2 July 2012 ICS 43.040.10; 43.100 Supersedes EN 1648-2:2004English Version Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations - Part 2: Motor caravans Vhicules habitables de loisirs - Installations lectriques trs basse tension de 12 V en cou
6、rant continu - Partie 2: Autocaravanes Bewohnbare Freizeitfahrzeuge - Elektrische Anlagen fr DC12 V - Teil 2: Motorcaravans This European Standard was approved by CEN on 16 June 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving
7、this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three officia
8、l versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Au
9、stria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swe
10、den, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national
11、Members. Ref. No. EN 1648-2:2012: EBS EN 1648-2:2012EN 1648-2:2012 (E) 2 Contents Page Foreword 4Introduction . 51 Scope 62 Normative references 63 Terms and definitions . 64 Power supply 64.1 General 64.2 Auxiliary batteries 74.2.1 General 74.2.2 Type of battery . 74.2.3 Capacity 74.2.4 Terminals 7
12、4.2.5 Location 74.2.6 Auxiliary battery compartment . 74.2.7 Warning notice . 84.3 Other sources of supply . 84.3.1 Generators and transformer/rectifiers unit . 84.3.2 Regenerative sources . 84.4 Protective measures 95 Wiring 95.1 Cable and fixed wiring cross-sectional areas . 95.2 Fixed wiring 95.2
13、.1 Cables . 95.2.2 Type of cable 95.2.3 Cable installation . 95.2.4 Supporting of cables . 95.2.5 Connections . 95.2.6 Auxiliary battery cables 95.2.7 Prohibited cable runs and LPG installations 96 Overcurrent protection 106.1 Protection of positive conductors . 106.2 Types of device 106.3 Installat
14、ion of fuses . 106.4 Prohibited locations 107 Installation of appliances 107.1 General 107.2 Selection and connection of appliances . 117.3 Socket outlets 117.4 Battery charger 117.5 External luminaires 117.6 Voltage drop . 118 Users Handbook . 11Annex A (informative) Relation of cable cross-section
15、al area, current flow and cable length for fixed wiring installations 13A.1 General 13A.2 Graphs for obtaining minimum cross-sectional areas 13A.3 Calculation of the minimum cross-sectional areas 14Bibliography 15BS EN 1648-2:2012EN 1648-2:2012 (E) 3 Page Figures Figure 1 Overview of relevant Europe
16、an Standards applying to leisure accommodation vehicles . 5 Figure A.1 Graph for obtaining minimum cross-sectional area for conductors for fixed wiring installations with a voltage drop of 0,8 V . 13 Figure A.2 Graph for obtaining minimum cross-sectional area for conductors for battery cable install
17、ations with a voltage drop of 0,3 V . 14 BS EN 1648-2:2012EN 1648-2:2012 (E) 4 Foreword This document (EN 1648-2:2012) has been prepared by Technical Committee CEN/TC 245 “Leisure accomodation vehicles”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a
18、 national standard, either by publication of an identical text or by endorsement, at the latest by January 2013, and conflicting national standards shall be withdrawn at the latest by January 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of
19、 patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1648-2:2004. The main technical changes since the previous edition are: a) Requirements on tube diameter deleted in 4.2.6 b); b) Reference to EC directive 2007/
20、46/EC, Annex II added in 4.2.6; c) Clarification added to 4.2.7 and Clause 8 that the warning notice shall be written in the language(s) of the country in which the caravan is to be sold for the first time; d) Sub-clause 4.4 amended; e) Sub-clause 5.2 “Fixed wiring“ amended; f) Note added in 6.2; g)
21、 Clause 7 “Installation of appliances“ amended; h) Normative references adapted to above changes; i) Annex A revised editorially j) Figure 1 added to Foreword. EN 1648, Leisure accommodation vehicles - 12 V direct current extra low voltage electrical installations contains the following parts: Part
22、1: Caravans; Part 2: Motor caravans (the present document). This document is one of a series covering the habitation aspects of leisure accommodation vehicles. Requirements for 12 V direct current extra low voltage electrical installations for caravans are specified in EN 1648-1. According to the CE
23、N/CENELEC Internal Regulations, the national standards organisations of the following coun-tries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hung
24、ary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1648-2:2012EN 1648-2:2012 (E) 5 Introduction Figure 1 gives an overview of the relevant European St
25、andards for caravans, motor caravans and caravan holiday homes. Figure 1 Overview of relevant European Standards applying to leisure accommodation vehicles BS EN 1648-2:2012EN 1648-2:2012 (E) 6 1 Scope This European Standard specifies safety, health and functional requirements for 12 V direct curren
26、t (DC) extra low voltage (ELV) electrical installations for habitation aspects of motor caravans. It applies only to installations which are electrically connected with the electrical installation of the base vehicle or which can be electrically connected with it by means of change-over devices. Thi
27、s European Standard also specifies the ELV output requirements of low voltage (LV) equipment that may be used to provide an ELV supply but it does not specify safety, technical and functional requirements for LV appliances and installations. Requirements for LV installations are specified in HD 6036
28、4-7-721 2. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includin
29、g any amendments) applies. EN 1646-1, Leisure accommodation vehicles Motor caravans Part 1: Habitation requirements relating to health and safety EN 13878:2003, Leisure accommodation vehicles Terms and definitions EN 60529, Degrees of protection provided by enclosures (IP code) (IEC 60529) EN 60898-
30、2, Electrical accessories Circuit-breakers for overcurrent protection for household and similar installations Part 2: Circuit-breakers for a.c. and d.c. operation (IEC 60898-2) HD 21 (series), Cables of rated voltages up to and including 450/750 V and having thermoplastic insulation HD 22 (series),
31、Cables of rated voltages up to and including 450/750 V and having cross-linked insulation ISO 6722 (series), Road vehicles 60 V and 600 V single-core cables ISO 7010, Graphical symbols Safety colours and safety signs Registered safety signs ISO 8820-1, Road vehicles Fuse-links Part 1: Definitions an
32、d general test requirements ISO 8820-3, Road vehicles Fuse-links Part 3: Fuse-links with tabs (blade type) Type C (medium), Type E (high current) and Type F (miniature) ISO 8820-4, Road vehicles Fuse-links Part 4: Fuse-links with female contacts (type A) and bolt-in contacts (type B) and their test
33、fixtures 3 Terms and definitions For the purposes of this document the terms and definitions given in EN 13878:2003 apply. 4 Power supply 4.1 General The power supply shall be a nominal DC 12 V (minimum 11 V and maximum 15 V) obtained from an auxiliary battery, except in the case of a motor caravan
34、where the overall length multiplied by the overall width does not exceed 8,5 m2plan area. In this case, it is permissible to use only the base vehicle battery. BS EN 1648-2:2012EN 1648-2:2012 (E) 7 NOTE A power supply with a nominal voltage different than DC 12 V is not allowed. The supply of the au
35、xiliary battery shall be obtained from the electrical installation of the base vehicle or from one or more of the following sources: a) battery charger (see 7.4); Where the charger is combined with an AC/DC converter (see d) and 4.3.1) fixed within the motor caravan, then individual items of current
36、 using equipment can also be supplied with electricity directly from this AC/DC converter. b) generator that is driven by any form of energy (see 4.3); c) solar energy cells (see 4.3); d) LV supply via an on-board mounted AC/DC converter (e.g. transformer, switching power supply) that complies with
37、the requirements of the relevant standards in accordance with directive 2006/95/EC and subsequent amendments. It shall be ensured that the auxiliary battery will be automatically disconnected from the 12 V power supply of the base vehicle when the engine of the base vehicle is turned off. If several
38、 sources of supply are used it shall be ensured that there is no unfavourable interaction. 4.2 Auxiliary batteries 4.2.1 General An auxiliary battery shall only be intended for the electric power supply of the living area. 4.2.2 Type of battery An auxiliary battery shall be of the rechargeable type.
39、 Non-rechargeable batteries are not auxiliary batteries according to 4.2. They may be used however, provided that they are used in circuits separated from other sources of electrical supply. 4.2.3 Capacity An auxiliary battery shall have a minimum capacity of at least 60 Ampere-hours (Ah) at 20 h di
40、scharge rate. NOTE It is recommended to use a battery designed to be discharged over long periods at a relatively low current. 4.2.4 Terminals Auxiliary battery terminals shall be clearly and durably marked “+” and “. Connections to auxiliary battery terminals shall be securely clamped or bolted to
41、ensure continuous contact and shall be insulated unless the auxiliary battery is provided with an insulating cover. 4.2.5 Location If an auxiliary battery is not installed in the engine compartment, it shall be placed in a compartment according to 4.2.6, which is designed to protect it from mechanic
42、al damage, with easy access for maintenance and/or removal and secured to prevent movement of the battery, e.g. when the motor caravan is in motion. 4.2.6 Auxiliary battery compartment An acid resistant liquid tight tray shall be installed under an auxiliary battery whose electrolyte is liquid capab
43、le of holding at least 20 % of the electrolyte capacity of the recommended battery, when in place. BS EN 1648-2:2012EN 1648-2:2012 (E) 8 The interior of an auxiliary battery compartment shall be ventilated and protected against the corrosive effect of acid-laden gases, either by a) installing a seal
44、ed auxiliary battery that incorporates an external ventilating kit that is taken to the exterior of the motor caravan; or b) installing an auxiliary battery in an enclosed battery compartment that is protected internally against corrosion and is ventilated directly to the exterior of the motor carav
45、an by means of a suitable tube in accordance with the battery manufacturers instructions or as supplied by the manufacturer of the auxiliary battery; or c) ventilating the compartment at both low-level and high-level to the exterior of the motor caravan. The construction of the compartment shall hav
46、e gas tight joints and seams, including the sides of the ventilator openings, be of acid-resistant material or have an anti-corrosive finish. The minimum size of ventilation shall be not less than 80 mm2at low level and not less than 80 mm2at high level. If the compartment opens into the interior of
47、 the motor caravan, the lid shall provide an air seal. The requirements concerning the protection against corrosion and ventilation are not applicable if batteries with bound electrolytes are used. If an auxiliary battery is not provided, then the position and instructions for the installation of th
48、e battery and compartment, in accordance with a), b) or c), shall be included in the Users Handbook according to Clause 8 and a notice shall be fixed in or near the proposed location stating: “For instructions on auxiliary battery installation, see Users Handbook”. When the manufacturer makes no pro
49、vision for the installation of an auxiliary battery, the following statement shall be made in the Users Handbook: “This motor caravan has not been designed to accommodate an auxiliary battery. Do not fit one.” For underslung battery, a minimum ground clearance shall be observed in compliance with directive 2007/46/EC, Annex II. 4.2.7 Warning notice A warning notice shall be fixed in a prominent position near the auxiliary battery or