EN 1827-1999 en Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only -.pdf

上传人:刘芸 文档编号:709354 上传时间:2019-01-03 格式:PDF 页数:48 大小:774.32KB
下载 相关 举报
EN 1827-1999 en Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only -.pdf_第1页
第1页 / 共48页
EN 1827-1999 en Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only -.pdf_第2页
第2页 / 共48页
EN 1827-1999 en Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only -.pdf_第3页
第3页 / 共48页
EN 1827-1999 en Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only -.pdf_第4页
第4页 / 共48页
EN 1827-1999 en Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only -.pdf_第5页
第5页 / 共48页
点击查看更多>>
资源描述

1、|BRITISH STANDARD BS EN 1827:1999IncorporatingcorrigendumICS 13.340.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWRespiratory protective devices Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only

2、 Requirements, testing, marking+A1:2009August 1999National forewordThis British Standard is the UK implementation of EN 1827:1999+A1:2009. It supersedes BS EN 1827:1999, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicati

3、ng changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“.The UK participation in its preparation was entrusted by Technical Committee PH/4, Respiratory protection, to Subcommittee PH/4/3, Facepieces.A list of organizations represe

4、nted on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 1827

5、:1999+A1:2009This British Standard, having been prepared under the direction of the Health and Environment Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 June 1999 BSI 2009Amendments/corrigenda issued since publicationAmd. No. Date Text aff

6、ected10669Corrigendum No. 1August 1999 Title corrected on front cover31 August 2009 Implementation of CEN amendment A1:2009ISBN 978 0 580 62119 2EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1827:1999+A1 June 2009 ICS 13.340.30 Supersedes EN 1827:1999English Version Respiratory protective dev

7、ices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only - Requirements, testing, marking Appareils de protection respiratoire - Demi-masques sans soupape inspiratoire et avec filtres dmontables, contre les gaz, contre l

8、es gaz et les particules, ou contre les particules uniquement - Exigences, essais, marquage Atemschutzgerte - Halbmasken ohne Einatemventile und mit trennbaren Filtern zum Schutz gegen Gase, Gase und Partikeln oder nur Partikeln - Anforderungen, Prfung, Kennzeichnung This European Standard was appro

9、ved by CEN on 26 December 1998 and includes Amendment 1 approved by CEN on 1stMay 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date list

10、s and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the resp

11、onsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, I

12、celand, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Ave

13、nue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1827:1999+A1:2009: EEN 1827:1999+A1:2009 (E) 2 Contents Foreword 3Introduction 41 Scope 42 Normative references 43 Terms and definitions 54 Descrip

14、tion 55 Classification 56 Designation 67 Requirements 67.1 General 67.2 Nominal values and tolerances 77.3 Visual inspection 77.4 Materials 77.5 Flammability 77.6 Cleaning and disinfecting 77.7 Filter material 77.8 Finish of parts 77.9 Demountable parts 77.10 Head harness 87.11 Connections 87.12 Exh

15、alation valves 87.13 Packaging 87.14 Mass 97.15 Gas filter capacity 97.16 Particle filter penetration 117.17 Clogging (Optional) 117.18 Compatibility with skin 127.19 Carbon dioxide content of inhalation air 127.20 Breathing resistance without clogging137.21 Inward leakage 157.22 Field of vision 157

16、.23 Practical performance 158 Testing 158.1 General 158.2 Conditioning 158.3 Visual inspection 188.4 Flammability 188.5 Cleaning and disinfecting 198.6 Exhalation valves (if fitted) 198.7 Gas filter capacity 218.8 Particle filter penetration 218.9 Clogging 218.10 Carbon dioxide content of inhalation

17、 air 218.11 Breathing resistance 258.12 Inward leakage 268.13 Practical performance 369 Marking 389.1 Packaging 389.2 Half mask 399.3 Filters 3910 Information supplied by the manufacturer 40Table 8 - Summary of requirements and tests 41Annex A (informative) Marking 43Annex ZA (informative) Clauses o

18、f this European Standard addressing essential requirements or other provisions of EU Directives 44BS EN 1827:1999+A1:2009EN 1827:1999+A1:2009 (E) 3 Foreword This document (EN 1827:1999+A1:2009) has been prepared by Technical Committee CEN/TC 79 “Respiratory protective devices“, the secretariat of wh

19、ich is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2009, and conflicting national standards shall be withdrawn at the latest by December 2009. This European Standard supe

20、rsedes EN 1827:1999. This document includes Amendment 1, approved by CEN on 2009-05-01. The start and finish of text introduced or altered by amendment is indicated in the text by tags !“. This European Standard has been prepared under a mandate given to CEN by the European Commission and the Europe

21、an Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this standard. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following cou

22、ntries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Sp

23、ain, Sweden, Switzerland and the United Kingdom. BS EN 1827:1999+A1:2009EN 1827:1999+A1:2009 (E) 4 Introduction A given respiratory protective device can only be approved when the individual components satisfy the requirements of the test specification which may be a complete standard or part of a s

24、tandard, and practical performance tests have been carried out successfully on complete apparatus where specified in the appropriate standard. If for any reason a complete apparatus is not tested then simulation of the apparatus is permitted provided the respiratory characteristics and weight distri

25、bution are similar to those of the complete apparatus. 1 Scope This European Standard specifies performance requirements, test methods and marking requirements for half masks (re-usable) without inhalation valves and with separable filters (designed for a maximum of single shift use) to protect agai

26、nst gases or gases and particles or particles only. It does not cover devices designed for use in circumstances where there is or might be an oxygen deficiency (oxygen less than 17 % by volume) or for escape purposes. Laboratory and practical performance tests are included for the assessment of comp

27、liance with the requirements. 2 Normative references !The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) appl

28、ies.“ EN 132 Respiratory protective devices Definitions of terms and pictograms EN 134 Respiratory protective devices Nomenclature of components !deleted text“ !EN 143“ Respiratory protective devices Particle filters Requirements, testing, marking EN 148-1 Respiratory protective devices Threads for

29、facepieces Part 1: Standard thread connection EN 148-2 Respiratory protective devices Threads for facepieces Part 2: Centre thread connection EN 148-3 Respiratory protective devices Threads for facepieces Part 3: Thread connection M 45 x 3 !EN 149“ Respiratory protective devices Filtering half masks

30、 to protect against particles Requirements, testing, marking !deleted text“ !EN 13274-7:2008, Respiratory protective devices Methods of test Part 7: Determination of particle filter penetration“ !EN 14387:2004, Respiratory protective devices Gas filter(s) and combined filter(s) - Requirements, testi

31、ng, marking“ BS EN 1827:1999+A1:2009EN 1827:1999+A1:2009 (E) 5 !ISO 6941“ Textile fabrics Burning behaviour Measurement of flame spread properties of vertically oriented specimens 3 Terms and definitions For the purposes of this European Standard the definitions in EN 132 and the nomenclature from E

32、N 134 apply. Gas filters remove specified gases. Combined filters remove dispersed solid and/or liquid particles and specified gases. The term “gases“ is taken to include vapours. Particle filters remove solid and/or liquid particles. A solid aerosol is defined as a dispersion of solid particles in

33、air. A liquid aerosol is defined as a dispersion of liquid particles in air. 4 Description A half mask without inhalation valves covers the nose and mouth and the chin, has no inhalation valves and may or may not have exhalation valves. It comprises a facepiece and separable and replaceable filters.

34、 It provides adequate sealing for the intended use on the face of the wearer against the ambient atmosphere, when the skin is dry or moist and when the head is moved. Inhalation air enters through the filter and passes directly to the nose and mouth area of the device. Exhaled air passes through the

35、 filter and an exhalation valve (if fitted) to the ambient atmosphere. In addition to providing protection against gases these devices can be designed to protect against both solid and liquid aerosols. 5 Classification 5.1 General Half masks shall be classified according to the types and classes of

36、filters used. 5.2 Filter types Type FM A - for use against certain organic gases and vapours with a boiling point higher than 65 C as specified by the manufacturer. Type FM B - for use against certain inorganic gases and vapours as specified by the manufacturer (excluding carbon monoxide). Type FM E

37、 - for use against sulfur dioxide and other acid gases and vapours as specified by the manufacturer. Type FM K - for use against ammonia and organic ammonia derivatives as specified by the manufacturer. BS EN 1827:1999+A1:2009EN 1827:1999+A1:2009 (E) 6 Type FM AX - for use against certain low boilin

38、g organic compounds as specified by the manufacturer. Type FM SX - for use against specific named gases and vapours. !Type FM P NR - for single shift use against particles.“ Any combination of these types is permitted. 5.3 Filter classes 5.3.1 Gas filter classes Class 1 - low capacity (Gas 1). Class

39、 2 - medium capacity (Gas 2). The protection provided by class 2 devices includes that provided by the corresponding class 1 device of the same type. FM AX and FM SX filters are not classified. 5.3.2 Particle filter classes !Class 1 low filtering efficiency (FM P1 NR). Class 2 medium filtering effic

40、iency (FM P2 NR). Class 3 high filtering efficiency (FM P3 NR). The protection provided by a FM P2 NR - or FM P3 NR - filter also includes that provided by the corresponding filter of lower class or classes.“ 6 Designation Respiratory protective devices meeting the requirements of this European Stan

41、dard shall be designated as follows: !Half mask without inhalation valve EN 1827, year of publication, type, classification, option (where “D“ is an option for a non re-useable half mask without inhalation valves and mandatory for a re-useable half mask without inhalation valves). EXAMPLE Half mask

42、without inhalation valve EN 1827:1999 FM E1 P2 NR D.“ 7 Requirements 7.1 General In all tests, all test samples shall meet the requirements. BS EN 1827:1999+A1:2009EN 1827:1999+A1:2009 (E) 7 7.2 Nominal values and tolerances Unless otherwise specified, the values stated in this European Standard are

43、 expressed as nominal values. Except for temperature limits, values which are not stated as maxima or minima shall be subject to a tolerance of 5 %. Unless otherwise specified, the ambient temperature for testing shall be (24 8) C, and the temperature limits shall be subject to an accuracy of 1 C. 7

44、.3 Visual inspection The visual inspection shall include the marking and the information supplied by the manufacturer. Testing shall be done in accordance with 8.3. 7.4 Materials Materials used shall be suitable to withstand handling and wear over the period for which the half mask is designed to be

45、 used. After testing in accordance with 8.2.4, 8.12 and 8.13 none of the devices shall have suffered mechanical failure of the facepiece body, straps or filter elements. Testing shall be done in accordance with 8.3. 7.5 Flammability Parts of a complete device that might be exposed to a flame during

46、use shall not burn or continue to burn for more than 5 s after removal from the flame. Testing shall be done in accordance with 8.3 and 8.4. It is not required that the device still has to be useable after the test. 7.6 Cleaning and disinfecting Any part of the device designed to be used for more th

47、an a single shift (single-use), shall withstand the cleaning and disinfecting agents and procedures recommended by the manufacturer. Testing shall be done in accordance with 8.5. 7.7 Filter material Any material of the filter media or any gaseous products that may be released by the air flow through

48、 the filter shall not constitute a hazard or nuisance for the wearer. Testing shall be done in accordance with 8.3 and 8.13. 7.8 Finish of parts Parts of the device likely to come into contact with the wearer shall have no sharp edges or burrs. Testing shall be done in accordance with 8.3. 7.9 Demou

49、ntable parts All parts designed to be demountable shall be readily connected and secured, where possible by hand. BS EN 1827:1999+A1:2009EN 1827:1999+A1:2009 (E) 8 Testing shall be done in accordance with 8.3 and 8.13. 7.10 Head harness 7.10.1 The head harness shall be designed so that the device can be