EN 251-2012 en Shower trays - Connecting dimensions《离心泵 连接尺寸规格》.pdf

上传人:rimleave225 文档编号:710051 上传时间:2019-01-03 格式:PDF 页数:16 大小:1,019.29KB
下载 相关 举报
EN 251-2012 en Shower trays - Connecting dimensions《离心泵 连接尺寸规格》.pdf_第1页
第1页 / 共16页
EN 251-2012 en Shower trays - Connecting dimensions《离心泵 连接尺寸规格》.pdf_第2页
第2页 / 共16页
EN 251-2012 en Shower trays - Connecting dimensions《离心泵 连接尺寸规格》.pdf_第3页
第3页 / 共16页
EN 251-2012 en Shower trays - Connecting dimensions《离心泵 连接尺寸规格》.pdf_第4页
第4页 / 共16页
EN 251-2012 en Shower trays - Connecting dimensions《离心泵 连接尺寸规格》.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 251:2012Shower trays ConnectingdimensionsBS EN 251:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 251:2012. Itsupersedes BS EN 2

2、51:2003 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/503, Sanitary appliances.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions

3、of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012 ISBN 978 0 580 68819 5 ICS 91.140.70 Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published und

4、er the authority of theStandards Policy and Strategy Committee on 30 November 2012. Amendments issued since publicationDate T e x t a f f e c t e dBS EN 251:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 251 October 2012 ICS 91.140.70 Supersedes EN 251:2003English Version Shower trays - Co

5、nnecting dimensions Receveurs de douche - Cotes de raccordement Duschwannen - Anschlussmae This European Standard was approved by CEN on 18 August 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the stat

6、us of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, Ge

7、rman). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croat

8、ia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and Un

9、ited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 251:2012:

10、EBS EN 251:2012EN 251:2012 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Connecting dimensions 43.1 Basic dimensions 43.2 Dimensions of the waste outlet hole .53.3 Clearance around the waste outlet hole 73.4 Dimensions and clearance around the overflow hole .8Annex A (normative) D

11、etermination of dimensions 9A.1 Test apparatus .9A.2 Determination of the fit of the control gauge in the waste outlet hole 11BS EN 251:2012EN 251:2012 (E) 3 Foreword This document (EN 251:2012) has been prepared by Technical Committee CEN/TC 163 “Sanitary appliances”, the secretariat of which is he

12、ld by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2013, and conflicting national standards shall be withdrawn at the latest by April 2013. Attention is drawn to the possibility that

13、 some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 251:2003. The main change to the document from the previous one is to include more defined informati

14、on for the waste control gauges shown in the Appendix A.1 According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, F

15、inland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 251:2012EN 251:2012 (E)

16、 4 1 Scope This European Standard specifies requirements for the connecting dimensions for shower trays, regardless of the material used for their manufacture. This European Standard applies to shower trays used for domestic purposes and complements the standards for shower trays made from different

17、 materials, the existing standard on waste fittings (EN 274-1) in terms of their dimensional requirements. NOTE Only dimensions are compulsory. The shape of the appliance in the figures is for illustration only; it in no way prejudices the shape of the appliance which is left to the initiative of th

18、e manufacturer. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (inc

19、luding any amendments) applies. EN 274-1, Waste fittings for sanitary appliances Part 1: Requirements 3 Connecting dimensions 3.1 Basic dimensions The basic dimensions H, a, H1and h1shall comply with those given in Table 1 to enable compatibility with waste fittings in accordance with EN 274-1 (see

20、also Annex A). Table 1 Basic dimensions (see Figure 1) Designation Symbol Values mm Remarks Vertical distance between the axis of the overflow hole, if provided, and the plane of the waste outlet hole H 165 to 260 Horizontal distance between the axis of the waste outlet hole and the axis of the over

21、flow hole, if provided a 110 to 170 Standard type waste fitting in accordance with EN 274-1 170 With a waste fitting specified or provided by the manufacturer Distance between the floor and the plane of the waste outlet hole measured at the centre line of the waste outlet hole h11) 130 For all showe

22、r trays with overflow 85 For all shower trays Distance between the axis of the overflow hole, if provided, and the spillover H1 60 1)Only applicable when the trap is to be accommodated above the finished floor.BS EN 251:2012EN 251:2012 (E) 5 Key 1 details shown in Figure 4 2 details shown in Figure

23、2 3 plane of the waste outlet hole 4 floor Figure 1 Basic dimensions 3.2 Dimensions of the waste outlet hole The dimensions of the waste outlet hole shall be as given in Table 2 to enable compatibility with EN 274-1 (see also Annex A). BS EN 251:2012EN 251:2012 (E) 6 Table 2 Dimensions of the waste

24、outlet hole (see Figure 2) Designation Symbol Values mm Remarks Diameter of the waste outlet hole D2 5232+6232+9032+Distance between the contact diameter of the control gauge and the bottom of the shower tray around the waste outlet hole e 2 Contact diameter of the control gauge D3 70 When D2 = 52 m

25、m 85 When D2 = 62 mm 115 When D2 = 90 mm Contact cone angle 120 Height between the contact diameter of the control gauge and the plane of the waste outlet hole h2 6 to 16 When D2= 52 mm 6 to 25 When D2 = 62 mm or 90 mm Sealing surface for waste fitting s 3 Key 1 bottom of the shower tray around the

26、waste outlet hole 2 plane of the waste outlet hole Figure 2 Waste outlet hole BS EN 251:2012EN 251:2012 (E) 7 3.3 Clearance around the waste outlet hole The clearance around the waste outlet hole shall comply with the dimensions given in Table 3. Table 3 Clearance around the waste outlet hole (see F

27、igure 3) Designation Symbol Values mm Remarks Radius of the circular area which shall remain free for installation of the waste fitting R 60 When D2= 52 mm 65 When D2 = 62 mm 80 When D2 = 90 mm Thickness of reinforcing material around the waste outlet hole f 15 Figure 3 Clearance around the waste ou

28、tlet hole BS EN 251:2012EN 251:2012 (E) 8 3.4 Dimensions and clearance around the overflow hole The dimensions and the clearance around the overflow hole, if provided, shall comply with Table 4. Table 4 Dimensions and clearance around the overflow hole (see Figure 4) Designation Symbol Values mm Dia

29、meter of the overflow hole D1 5232+Diameter of the flat area intended to accommodate the gasket on reverse side D4 75 Diameter of the clearance around the overflow hole intended for the overflow fitting D5 80 Depth of the clearance around the overflow hole intended for the overflow fitting h4 60 Thi

30、ckness of the material within D4t1)2 to 10 Angle of flat area of D4in relation to the plane of the waste outlet hole (98 5) Diameter of the flat area intended to accommodate the gasket on the inside of the shower tray D6 65 1) The dimension t shall have a maximum variation of 1 mm NOTE The flatness

31、tolerance applies within D4. Figure 4 Dimensions and clearance around any overflow hole BS EN 251:2012EN 251:2012 (E) 9 Annex A (normative) Determination of dimensions A.1 Test apparatus a) Length and/or diameter measuring devices; b) Control gauges in accordance with Figures A.1, A.2 and A.3. Untol

32、eranced dimensions are for reference only. Dimensions in millimetres Figure A.1 Control gauge D2= 52 mm BS EN 251:2012EN 251:2012 (E) 10 Dimensions in millimetres Figure A.2 Control gauge D2= 62 mm Dimensions in millimetres Figure A.3 Control gauge D2= 90 mm BS EN 251:2012EN 251:2012 (E) 11 A.2 Dete

33、rmination of the fit of the control gauge in the waste outlet hole Place the relevant control gauge in the waste outlet hole and verify that: a) the waste outlet of the shower tray can be fitted in the waste hole (Dimension D2in Figure 2); b) the contact diameter of the control gauge (dimension D3 i

34、n Figure 2) makes contact with or is 1 mm of making contact over its entire circumference; c) the cylindrical portion of the control gauge is level with or projecting below the plane of the waste outlet hole (dimension h2in Figure 2); d) the top surface of the control gauge is below the level of the

35、 bottom of the shower tray around the waste outlet hole (dimension e in Figure 2); e) the contact cone angle (angle in Figure 2) is 120. This page deliberately left blankThis page deliberately left blankBSI is the independent national body responsible for preparing British Standards and other standa

36、rds-related publications, information and services. It presents the UK view on standards in Europe and at the international level. BSI is incorporated by Royal Charter. British Standards and other standardisation products are published by BSI Standards Limited.British Standards Institution (BSI)rais

37、ing standards worldwideBSI389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards and PASs are periodically updated by amendment or revision. Users of British Standards and PASs should make sure that they possess the latest amendments or editions.It is the constan

38、t aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using British Standards would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside frontcover. Similary f

39、or PASs, please notify BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers BSI Subscribing Members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of British Standards and PASs.Tel: +44 (0)20 8996 7669

40、Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy versions of standards directly using acredit card from the BSI Shop on the website addition all orders for BSI, international and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996

41、9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, BSI will supply the British Standard implementation of the relevant international standard, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, Europeanand inte

42、rnational standards through its Knowledge Centre.Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005Email: BSI Subscribing Members are kept up to date with standards developments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact Member

43、ship Administration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards and PASs via British Standards Online can be found at information about British Standards is available on the BSI website at www.bsi- the data, software and docume

44、ntation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that own copyright in the information used (such as the international standardisation bodies) has formally licensed such information to BSI for commerical publicat

45、ion and use. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude

46、the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Department.Tel: +44 (0)20 8996 7070Email:

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1