EN 2714-002-2016 en Aerospace series - Cables electrical single and multicore for general purpose - Operating temperatures between - 55 and 260 - Part 002 Screened and jacketed - G.pdf

上传人:arrownail386 文档编号:710306 上传时间:2019-01-03 格式:PDF 页数:18 大小:1.90MB
下载 相关 举报
EN 2714-002-2016 en Aerospace series - Cables electrical single and multicore for general purpose - Operating temperatures between - 55 and 260 - Part 002 Screened and jacketed - G.pdf_第1页
第1页 / 共18页
EN 2714-002-2016 en Aerospace series - Cables electrical single and multicore for general purpose - Operating temperatures between - 55 and 260 - Part 002 Screened and jacketed - G.pdf_第2页
第2页 / 共18页
EN 2714-002-2016 en Aerospace series - Cables electrical single and multicore for general purpose - Operating temperatures between - 55 and 260 - Part 002 Screened and jacketed - G.pdf_第3页
第3页 / 共18页
EN 2714-002-2016 en Aerospace series - Cables electrical single and multicore for general purpose - Operating temperatures between - 55 and 260 - Part 002 Screened and jacketed - G.pdf_第4页
第4页 / 共18页
EN 2714-002-2016 en Aerospace series - Cables electrical single and multicore for general purpose - Operating temperatures between - 55 and 260 - Part 002 Screened and jacketed - G.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、Aerospace series Cables, electrical, single and multicore for general purpose Operatingtemperatures between 55 Cand 260 CPart 002: Screened and jacketed GeneralBS EN 2714-002:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard i

2、s the UK implementation of EN 2714-002:2016. Itsupersedes BS EN 2714-002:2012 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optic technology.A list of organizations represented on this committee can be obt

3、ained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 92607 5ICS 49.060Compliance with a

4、British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2017.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 2714-002:2016EUROPEAN STANDARD N

5、ORME EUROPENNE EUROPISCHE NORM EN 2714-002 December 2016 ICS 49.060 Supersedes EN 2714-002:2012English Version Aerospace series - Cables, electrical, single and multicore for general purpose - Operating temperatures between - 55 C and 260 C - Part 002: Screened and jacketed - General Srie arospatial

6、e - Cbles, lectriques, mono et multiconducteurs dusage gnral - Tempratures de fonctionnement comprises entre - 55 C et 260 C - Partie 002: Blinds et gains - Gnralits Luft- und Raumfahrt - Leitungen, elektrisch, ein- und mehradrig, fr allgemeine Verwendung - Betriebstemperaturen zwischen - 55 C und 2

7、60 C - Teil 002: Geschirmt und ummantelt - Allgemeines This European Standard was approved by CEN on 21 November 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without

8、any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other lang

9、uage made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmar

10、k, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FO

11、R STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 2714-002:2016 EBS EN 2714-002:201

12、6EN 2714-002:2016 (E) 2 Contents Page European foreword 3 1 Scope 4 2 Normative references 4 3 Terms, definitions and symbols . 5 4 List of product standards . 5 5 Construction 6 6 Identification and marking 12 7 Technical specification . 13 BS EN 2714-002:2016EN 2714-002:2016 (E) 3 European forewor

13、d This document (EN 2714-002:2016) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Association

14、s and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2017, and conflicting national standards shall be

15、 withdrawn at the latest by June 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 2714-002:2012. Acco

16、rding to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany

17、, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 2714-002:2016EN 2714-002:2016 (E) 4 1 Scope This European Standard specifies the list

18、 of product standards and common characteristics of single and multicore screened and jacketed electrical cables for use in the on-board electrical systems of aircraft, at operating temperatures between 55 C and 260 C (unless otherwise specified in product standards). 2 Normative references The foll

19、owing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2235, Aerosp

20、ace series Single and multicore electrical cables, screened and jacketed Technical specification EN 2714-003, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 003: Screened (spiral) and jacketed, ink jet printable Produc

21、t standard EN 2714-004, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 004: Screened (braided) and jacketed, ink jet printable Product standard EN 2714-005, Aerospace series Cables, electrical, single and multicore for

22、 general purpose Operating temperatures between 55 C and 260 C Part 005: Screened (spiral) and jacketed, CO2laser printable Product standard EN 2714-006, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 006: Screened (br

23、aided) and jacketed, CO2laser printable Product standard EN 2714-007, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 007: Screened (spiral) and jacketed, UV laser printable Product standard EN 2714-008, Aerospace serie

24、s Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 008: Screened (braided) and jacketed, UV laser printable Product standard EN 2714-009, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperature

25、s between 55 C and 260 C Part 009: Screened (spiral) and jacketed, YAG X3 laser printable Product standard EN 2714-010, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 010: Screened (braided) and jacketed, YAG X3 laser

26、printable Product standard EN 2714-011, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 011: DM family, screened (spiral) and jacketed, UV laser printable Product standard BS EN 2714-002:2016EN 2714-002:2016 (E) 5 EN 27

27、14-012, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 012: DM family, screened (braided) and jacketed, UV laser printable Product standard EN 2714-013, Aerospace series Cables, electrical, single and multicore for gen

28、eral purpose Operating temperatures between 55 C and 260 C Part 013: DR family, screened (spiral) and jacketed, UV laser printable Product standard EN 2714-014, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 014: DR fa

29、mily, 4 to 11 cores, taped, screened (braided) and jacketed, UV laser printable Product standard EN 2714-015, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 015: DZ family, screened (spiral) and jacketed, UV laser prin

30、table for use in low pressure atmosphere Product standard 1)EN 3475-100, Aerospace series Cables, electrical, aircraft use Test methods Part 100: General EN 3838, Aerospace series Requirements and tests on user-applied markings on aircraft electrical cables TR 6058, Aerospace series Cable code ident

31、ification list 2)3 Terms, definitions and symbols For the purposes of this document, the terms, definitions and symbols given in EN 3475-100 apply. 4 List of product standards EN 2714-003, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55

32、 C and 260 C Part 003: Screened (spiral) and jacketed, ink jet printable Product standard EN 2714-004, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 004: Screened (braided) and jacketed, ink jet printable Product stan

33、dard EN 2714-005, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 005: Screened (spiral) and jacketed, CO2laser printable Product standard EN 2714-006, Aerospace series Cables, electrical, single and multicore for gener

34、al purpose Operating temperatures between 55 C and 260 C Part 006: Screened (braided) and jacketed, CO2laser printable Product standard 1)In preparation at the date of publication of this European Standard. 2)Published as ASD-STAN Technical Report at the date of publication of this European Standard

35、. (http:/www.asd-stan.org/) BS EN 2714-002:2016EN 2714-002:2016 (E) 6 EN 2714-007, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 007: Screened (spiral) and jacketed, UV laser printable Product standard EN 2714-008, Ae

36、rospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 008: Screened (braided) and jacketed, UV laser printable Product standard EN 2714-009, Aerospace series Cables, electrical, single and multicore for general purpose Operatin

37、g temperatures between 55 C and 260 C Part 009: Screened (spiral) and jacketed, YAG X3 laser printable Product standard EN 2714-010, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 010: Screened (braided) and jacketed,

38、YAG X3 laser printable Product standard EN 2714-011, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 011: DM family, screened (spiral) and jacketed, UV laser printable Product standard EN 2714-012, Aerospace series Cabl

39、es, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 012: DM family, screened (braided) and jacketed, UV laser printable Product standard EN 2714-013, Aerospace series Cables, electrical, single and multicore for general purpose Operating temper

40、atures between 55 C and 260 C Part 013: DR family, screened (spiral) and jacketed, UV laser printable Product standard EN 2714-014, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 014: DR family, 4 to 11 cores, taped, s

41、creened (braided) and jacketed, UV laser printable Product standard EN 2714-015, Aerospace series Cables, electrical, single and multicore for general purpose Operating temperatures between 55 C and 260 C Part 015: DZ family, screened (spiral) and jacketed, UV laser printable for use in low pressure

42、 atmosphere Product standard 5 Construction 5.1 Number of cores See Table 1. Table 1 Number of cores Number of cores 1 2 3 4 5 6 7 8 9 10 11 Code A B C D E F G H J K L BS EN 2714-002:2016EN 2714-002:2016 (E) 7 5.2 Colour coding of cores and jacket See Tables 2 to 10. Table 2 Code A Number of cores i

43、n cables Colours 1 White 2 White Blue 3 White Blue Yellow 4 White Blue Yellow Green NOTE Jacket: for codes 002/006/012 light blue, white for other sizes. Table 3 Code B Number of cores in cables Colours 01 White 02 White Blue 03 White Blue Orange 04 White Blue Orange Green 05 White Blue Orange Green

44、 Red 06 White Blue Orange Green Red Black 07 White Blue Orange Green Red Black Yellow 08 White Blue Orange Green Red Black Yellow Violet 09 White Blue Orange Green Red Black Yellow Violet Grey 10 White Blue Orange Green Red Black Yellow Violet Grey Brown 11 White Blue Orange Green Red Black Yellow V

45、iolet Grey Brown Light green NOTE Jacket: for codes 002/006/012 light blue, white for other sizes. BS EN 2714-002:2016EN 2714-002:2016 (E) 8 Table 4 Code C Number of cores in cables Colours 01 White 02 White Blue 03 White Blue Orange 04 White Blue Orange Green 05 White Blue Orange Green Red 06 White

46、 Blue Orange Green Red Black 07 White Blue Orange Green Red Black Yellow 08 White Blue Orange Green Red Black Yellow Violet 09 White Blue Orange Green Red Black Yellow Violet Grey 10 White Blue Orange Green Red Black Yellow Violet Grey Brown 11 White Blue Orange Green Red Black Yellow Violet Grey Br

47、own Light green NOTE Jacket: white. Table 5 Code D Number of cores in cables Band group configuration Number of rings Wide Narrow 1 No ring on the first core 0 0 2 0 2 3 0 3 4 0 4 5 0 5 6 0 6 7 0 7 8 1 1 9 1 2 10 1 3 11 1 4 Marking with colour rings. Basic colour of cores: same as jacket. Colour of

48、rings: green. Jacket base: pink for codes 001/006/020 white for odes 02/010/030 light green for codes 004/012/050/051. BS EN 2714-002:2016EN 2714-002:2016 (E) 9 Arrangement of colour rings (see Figure 1): 2nd core 3rd core 4th core 8th core Key 1 12 mm to 17 mm 2 1,5 mm to 3 mm 3 3,5 mm to 5 mm 4 3 mm to 6 mm Figure 1 Each ring shall cover at least 3/4 of the circumference. The wide rings shall be twice the width of the narrow rings. Table 6 Code E