EN 2996-005-2006 en Aerospace series - Circuit breakers three-pole temperature compensated rated current 1 A to 25 A - Part 005 With polarized signal contact - Product standard《航空航.pdf

上传人:王申宇 文档编号:710488 上传时间:2019-01-03 格式:PDF 页数:16 大小:384.99KB
下载 相关 举报
EN 2996-005-2006 en Aerospace series - Circuit breakers three-pole temperature compensated rated current 1 A to 25 A - Part 005 With polarized signal contact - Product standard《航空航.pdf_第1页
第1页 / 共16页
EN 2996-005-2006 en Aerospace series - Circuit breakers three-pole temperature compensated rated current 1 A to 25 A - Part 005 With polarized signal contact - Product standard《航空航.pdf_第2页
第2页 / 共16页
EN 2996-005-2006 en Aerospace series - Circuit breakers three-pole temperature compensated rated current 1 A to 25 A - Part 005 With polarized signal contact - Product standard《航空航.pdf_第3页
第3页 / 共16页
EN 2996-005-2006 en Aerospace series - Circuit breakers three-pole temperature compensated rated current 1 A to 25 A - Part 005 With polarized signal contact - Product standard《航空航.pdf_第4页
第4页 / 共16页
EN 2996-005-2006 en Aerospace series - Circuit breakers three-pole temperature compensated rated current 1 A to 25 A - Part 005 With polarized signal contact - Product standard《航空航.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 2996-005:2006Aerospace series Circuit breakers, three-pole, temperature compensated, rated current 1 A to 25 A Part 005: With polarized signal contact Product standardThe European Standard EN 2996-005:2006 has the status of a British StandardICS 49.060g49g50g3g38g50g51g60g44g49

2、g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 2996-005:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 3

3、1 January 2007 BSI 2007ISBN 978 0 580 50014 5National forewordThis British Standard was published by BSI. It is the UK implementation of EN 2996-005:2006.The UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Pa

4、nel ACE/6/-/5, Aerospace Protection for electrical systems.A list of organizations represented on ACE/6/-/5 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Complianc

5、e with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 2996-005August 2006ICS 49.060English VersionAerospace series - Circuit breakers, three-pole, temperaturecompensated, rate

6、d current 1 A to 25 A - Part 005: Withpolarized signal contact - Product standardSrie arospatiale - Disjoncteurs tripolaires compenss entemprature, intensits nominales 1 A 25 A - Partie 005 :Avec contact de signalisation polaris - Norme de produitLuft- und Raumfahrt - Schutzschalter, dreipolig,Tempe

7、raturkompensiert, Nennstrme von 1 A bis 25 A -Teil 005: Mit polarisiertem Signalkontakt - ProduktnormThis European Standard was approved by CEN on 5 June 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the

8、 status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German).

9、A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Es

10、tonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPIS

11、CHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 2996-005:2006: E2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Dimensions and mass.4 4

12、 Characteristics.6 5 Designation 11 6 Rated current code 11 7 Delivery codes .11 8 Marking .12 9 Technical specification .12 EN 2996-005:20063 Foreword This European Standard (EN 2996-005:2006) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STA

13、N). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the statu

14、s of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withdrawn at the latest by February 2007. Attention is drawn to the possibility that some of the elements of this document may be the su

15、bject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium,

16、Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 2996-005:20064 1 Scope This st

17、andard specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 1 A to 25 A, used in aircraft on-board circuits at a temperature between 55 C and 125 C for ratings 15 A and 55 C and 90 C for ratings 15 A and at an altitude of 22 000 m max. These

18、 circuit breakers are operated by a push-pull type single push button (actuator), with delayed action “trip-free“ tripping with a polarized signal contact which is open when main contacts are closed, and inversely. They will continue to function up to the short-circuit current. 2 Normative reference

19、s The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2996-001, Aerospace series Circuit breakers,

20、 three-pole, temperature compensated, rated current 1 A to 25 A Part 001: Technical specification. EN 3155-016, Aerospace series Electrical contacts used in elements of connection Part 016: Contacts, electrical, male, type A, crimp, class S Product standard.EN 3841-305, Aerospace series Circuit brea

21、kers Test methods Part 305: Short-circuit performance. EN 6113, Aerospace series Circuit breaker, connecting and attachment hardware. 1)TR 6083, Aerospace series Cut-outs for installation of electrical components. 2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III

22、, class 2, composition C. 3)MIL-I-81969/14C, Installing and removal tools, connector electrical contact, type III, class 2, composition B. 3)MIL-S-19500, Semiconductor device, diode, silicon, fast recovery.3)FED-STD-595B, Colours used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional

23、characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to. Dimensions are in millimetres. See Figure 1. 1) Published as AECMA Prestandard at the date of publication of this standard. 2) Published as AECMA Technical Rep

24、ort at the date of publication of this standard. 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. EN 2996-005:20065 Key 1 Push button released 10 1 to 3 max. 2 Green colour according to FED-STD-595B No. 34090 11 3 White Gauge 20 connection pins according to EN31

25、55-016M2018 4 Marking area, see Clause 8. 12 Indicative value 25 (see note) 5 Circuits deviding partition 13 Rated current marking (white on green) 6 Connecting screw and washer 14 7 Push button pressed Positioning lug in accordance with the panel cut-out, as per TR6083C202 8 Lockwasher 15 Terminals

26、 shape free 9 Attachment nut F1 and F2: see EN 2996-001 “Mechanical tests“. NOTE Tools noted in subclause 4.2.4 shall be applied without interfering with the terminal 2 connection, even if circuit breakers are grouped. Figure 1 Configuration Dimensions Tolerances 341,50-0,5234,6min.50,5 A12439 8,4 0

27、,3C2B2A2C1B1A115,8max.0,5A16,5 max.12,8 0,517,5 215 0,8 15 0,80,5 AF2F11530 max.26,5 max.20 max.138 min.1013 0,5M12 x 13 min.6,35 0,42,5 0,318,5131 0,819,5 max.3 max.6453453A7 min.5 0,536 247 max.F1 and F2 : see EN 2996-001 table 3A2 B2 C2814 10,2 0,317119,8 max.5 3EN 2996-005:20066 3.2 Electrical d

28、iagram See Figure 2. Terminal No. : 1 and 2: Main contacts 3 and 5: Signal contacts Figure 2 Electrical diagram 3.3 Mass 64 g max. (delivery code A including hardware). 3.4 Panel mounting See EN 2996-001. 4 Characteristics 4.1 Material, surface treatment See EN 2996-001. 4.2 Mechanical characteristi

29、cs 4.2.1 Fasteners See EN 6113. 4.2.2 Recommended tightening torque of attaching nut for installation (4,75 0,25) Nm 4.2.3 Recommended tightening torque of connection hardware for installation (1,6 0,1) Nm A2 A1B2 B1C2 C13 5Push-button releasedA2 A1B2 B1C2 C13 5Push-button pressed3 5or3 5orEN 2996-0

30、05:20067 4.2.4 Recommended tools for contacts of auxiliary contact insertion and extraction plastic MIL-I-81969/14-11; metallic MIL-I-81969/1-02. 4.2.5 Resistance to vibrations 4.2.5.1 Combined test: ambient temperature at 70 C and vibrations Sinusoidal: 10 gn, see EN 2996-001. Random: 5,8 gn, see E

31、N 2996-001. Low frequencies: 10 gn, see EN 2996-001. 4.2.5.2 Combined test: ambient temperature at 85 C, altitude and vibrations Sinusoidal: 3 gn, see EN 2996-001. 4.2.6 Resistance to shocks 50 gn, see EN 2996-001. 4.2.7 Mechanical endurance See Table 6. 4.3 Environment characteristics 4.3.1 Humidit

32、y See EN 2996-001. 4.3.2 Corrosion See EN 2996-001. 4.3.3 Contaminating liquids See EN 2996-001. 4.3.4 Overvoltage caused by lightning See EN 2996-001. 4.4 Electrical characteristics 4.4.1 Nominal voltages of main contacts See Table 1. Table 1 Nominal voltage 115/200 V a.c., 360 Hz to 800 Hz EN 2996

33、-005:20068 4.4.2 Diode of signal contact characteristics Max. current at 125 C: 0,5 A. Peak repetitive reversal voltage: 800 V min. Quality standard: JANTX according to MIL-S-19500. 4.4.3 Voltage drop at nand at low current See Table 2. Table 2 Ratings A 1 2 2,5 3 5 7,5 10 15 20 25 U max. at n V 1,1

34、 0,75 0,70 0,55 0,35 0,30 0,30 0,25 0,25 0,20 U max. at = 100mA mV 110 40 30 18 8 4 3 2,5 2,5 2,5 Signal circuit : 28 V d.c.; I = 3 mA : U 1,0 V. NOTE When a signal contact has been operated with a power greater than 60 mW and/or with a voltage higher than 28 V d.c., it loses its low current quality

35、. 4.4.4 Minimum and maximum tripping thresholds See Table 3. Table 3 Overload (in % of n) Minimum thresholds value 1 h Maximum thresholds value 1 h Ambient temperatures C Ratings On ground At 22 000 m On ground 23 5 110 105 140 55 5 110 105 160 70 5 All 105 100 140 90 5 20 and 25 90 80 140 125 5 1 t

36、o 15 90 80 140 NOTE 1 For detection of minimum threshold, all the poles are connected in series. NOTE 2 For detection of maximum threshold, load value is: - increased by about 20 % when one pole is submitted to the load and other poles are not loaded; - increased by about 10 % when two poles are sub

37、mitted to the load and the other one is not loaded; - not increased when the two other poles are loaded at 0,9 n. EN 2996-005:20069 4.4.5 Overload trip See Table 4. Table 4 Overload (in % of n) 200 500 1 000 3 poles 1 pole 3 poles 1 pole 3 poles 1 pole Ambient temperatures C Ratings A Trip time s 23

38、 5 2 to 20 55 5 All 40 48 90 5 20 and 25 1,5 1,5 125 5 1 to 15 1,5 1,5 0,15 to 2,30 0,15 to 2,80 0,035 to 0,500 0,035 to 0,600 NOTE 1 When 3 poles are loaded, they will be connected in series. NOTE 2 When 1 pole is loaded, the two other poles are not loaded. 4.4.6 Short-circuit values See Table 5. T

39、able 5 Nominal voltage 115/ 200 V a.c., 360 Hz to 800 Hz 0,8 cos 1 Prospective currents 1 800 A r.m.s. 1 500 A r.m.s. 1 100 A r.m.s. Test altitudes On the ground and at maximum altitude (22 000 m, 4 000 Pa) On the ground and at cabin maximum altitude (4 600 m, 57 400 Pa) At maximum altitude (22 000

40、m, 4 000 Pa) Number of operations See note. 1 CO a+ 2 OCO b1 CO a+ 2 OCO bNOTE For the test at 1 800 A, an opening of the circuit by a destruction of the circuit breaker, (without bursting, flaming or thick smokes) is allowed even if this destruction happens during the first CO. If the product passe

41、s 1 CO + 2 OCO at 1 800 A/115 V a.c., tests at 1 100 A and 1 500 A will not be necessary. aBreak operation (for definition see EN 3841-305). bMake operation (for definition see EN 3841-305). 4.4.7 No-load and load endurance See Table 6. EN 2996-005:200610 Table 6 Number of operations to be provided

42、No-load Load 5 000 2 500 Main contacts ApplicableInductive 0,6 cos 0,7 n, 115/200 V a.c. - 360 Hz to 800 Hz All ratings Signal contacts ApplicableResistive 0,5 A, 28 V d.c. Resistive 3 mA, 28 V d.c Resistive 3 mA, 5 V d.c Lamp 0,2 A, 28 V d.c. NOTE 1 One operation corresponds to one closing + one op

43、ening. NOTE 2 Tolerances 5 % on current, voltage and frequency values. 4.4.8 Dielectric rigidity See Table 7. Table 7 Closed position Z = 0 m Z = 22 000 m A1, B1, C1 with attachment A1, B1, C1 with 3 A1, B1, C1 with 5 A1, A2 with B1, B2 and C1, C2 B1, B2 with A1, A2 and C1, C2 1 500 V 400 V 3 with 5

44、 3 and 5 with attachment 500 V 150 V Open position Z = 0 m Z = 22 000 m A1, B1, C1 with A2, B2, C2 A1, B1, C1, A2, B2, C2 with attachment 3 and 4 with A1, B1, C1 3 with 4 with A2, B2, C2 A1, A2 with B1, B2 and C1, C2 B1, B2 with A1, A2 and C1, C2 1 500 V 400 V 3 and 5 with attachment 500 V 150 V 4.4

45、.9 Insulation resistance According to EN 2996-001, Table 5. EN 2996-005:200611 5 Designation EXAMPLE Description block CIRCUIT BREAKER Identity block EN2996-005A20AA Number of EN standard Design code, A: green button Rated current code (see Table 8) Delivery code A (see Table 9) NOTE If necessary, t

46、he code I9005 shall be placed between the description block and the identity block. 6 Rated current code See Table 8. Table 8 Rating current n (A) 1 2 2,5 3 5 7,5 10 15 20 25 Marking on actuator 1 2 2 3 5 7 10 15 20 25 Rated current code 01A 02A 2A5 03A 05A 7A5 10A 15A 20A 25A 7 Delivery codes See T

47、able 9. Table 9 Connection and attachment hardware kits EN 6113 Delivery conditions Delivery code Kit part-No. aIncluded parts Pieces per part Fitted Supplied separately Connecting screw 6 Connecting lock washer 6 Attachment nut 1 A EN6113C1 Attachment lock washer 1 X Attachment nut 1 B EN6113B1 Att

48、achment lock washer 1 X aSpare parts could be ordered separately, for information see EN 6113. EN 2996-005:200612 8 Marking As defined on the drawing and unless otherwise specified by contract, marking shall include: the designation defined in Clause 5 (without delivery hardware code), on the packag

49、ing; the manufacture date (year, week); the manufacturers name or trademark; the electrical diagram and the terminal identification; the manufacturers part number (corresponding to the part number which includes connection and attachment hardware supplied separately in a bag). NOTE The marking could be on both opposite sides. For electrical diagram printed on the circuit breaker and/or terminal identification