EN 3660-065-2009 3125 Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 Cable outlet style K 90 Degrees for heat.pdf

上传人:confusegate185 文档编号:711113 上传时间:2019-01-03 格式:PDF 页数:18 大小:1.54MB
下载 相关 举报
EN 3660-065-2009 3125 Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 Cable outlet style K 90 Degrees for heat.pdf_第1页
第1页 / 共18页
EN 3660-065-2009 3125 Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 Cable outlet style K 90 Degrees for heat.pdf_第2页
第2页 / 共18页
EN 3660-065-2009 3125 Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 Cable outlet style K 90 Degrees for heat.pdf_第3页
第3页 / 共18页
EN 3660-065-2009 3125 Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 Cable outlet style K 90 Degrees for heat.pdf_第4页
第4页 / 共18页
EN 3660-065-2009 3125 Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065 Cable outlet style K 90 Degrees for heat.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、BS EN3660-065:2009ICS 49.060NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDAerospace series Cable outletaccessories for circularand rectangularelectrical and opticalconnectorsPart 065: Cable outlet, style K, 90, forheat shrinkable boot, shielded, sealed,self-lo

2、cking for EN 2997 and EN 4067 Product standardCopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-This British Standard was published under the authority of the Standards Policy and

3、Strategy Committee on 31January 2010 BSI 2010ISBN 978 0 580 67321 4Amendments/corrigenda issued since publicationDate CommentsBS EN 3660-065:2009National forewordThis British Standard is the UK implementation of EN 3660-065:2009. The UK participation in its preparation was entrusted to TechnicalComm

4、ittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct applicati

5、on. Compliance with a British Standard cannot confer immunityfrom legal obligations.Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EUROPEAN STANDARD NORME EUR

6、OPENNE EUROPISCHE NORM EN 3660-065 November 2009 ICS 49.060 English Version Aerospace series - Cable outlet accessories for circular and rectangular electrical and optical connectors - Part 065: Cable outlet, style K, 90, for heat shrinkable boot, shielded, sealed, self-locking for EN 2997 and EN 40

7、67 - Product standard Srie arospatiale - Accessoires arrire pour connecteurs circulaires et rectangulaires lectriques et optiques - Partie 065: Raccord type K, coud 90, blind, tanche, pour manchon thermortractable, auto-frein pour EN 2997 et EN 4067 - Norme de produit Luft- und Raumfahrt - Endgehuse

8、 fr elektrische und optische Rund- und Rechtecksteckverbinder - Teil 065: Endgehuse, Bauform K, 90, fr wrmeschrumpfende Bauteile, Schirmanschlu, abgedichtet, selbstsichernd fr EN 2997 und EN 4067 - Produktnorm This European Standard was approved by CEN on 20 June 2009. CEN members are bound to compl

9、y with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Manageme

10、nt Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the

11、official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia

12、, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for

13、 CEN national Members. Ref. No. EN 3660-065:2009: ECopyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 2 Contents Page Foreword 3 1 Scope 4 2

14、Normative references 4 3 Terms and definitions . 4 4 Characteristics . 5 5 Tests 9 6 Identification.14 7 Marking .15 8 Technical specification .15 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without lice

15、nse from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 3 Foreword This document (EN 3660-065:2009) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, t

16、his Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at th

17、e latest by May 2010, and conflicting national standards shall be withdrawn at the latest by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all suc

18、h patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,

19、 Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networ

20、king permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 4 1 Scope This European Standard defines a range of cable outlets, style K, for use under the following conditions: The mating connectors are listed in EN 3660-002. Temperature range, Class F : 65 C to 200 C; Class K

21、 : 65 C to 260 C; Class W : 65 C to 175 C. Associated electrical accessories : EN 3660-033 Metallic band (for shield termination backshells). These cable outlets are designed for termination of overall shielding braid or individual cable shields. They accommodate/permit the termination of heat shrin

22、kable boots. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591-100*,

23、 Aerospace series Elements of electrical and optical connection Test methods Part 100: General EN 2997 (all parts), Aerospace series Connectors, electrical, circular, coupled by threaded ring, fire-resistant or non fire-resistant, operating temperatures - 65 C to 175 C continuous, 200 C continuous,

24、260 C peak EN 3660-001:2006, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 001: Technical specification EN 3660-002, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 002: Inde

25、x of product standards EN 3660-033, Aerospace series Cable outlet accessories for circular and rectangular electrical and optical connectors Part 033: Metallic band Product standard 1)AS85049A, Connector accessories, electrical general specification for 2)DIN 82, Knurling 3 Terms and definitions For

26、 the purposes of this document, the terms and definitions given in EN 3660-001:2006 apply. *As well as all parts of EN 2591 quoted in this standard. 1) In preparation at the date of publication of this standard. 2) Published by: Society of Automotive Engineers, Inc. (SAE), 400 Commonwealth Drive, Wa

27、rrendale, PA 15096-0001. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 5 4 Characteristics 4.1 Dimensions and mass For dimensions and ma

28、ss, see Figure 1 and Table 1 to Table 4. For cable entry dimensions, see 4.2. Dimensions in millimetres Key 1 Thread C 2 Marking 3 Number of teeth N 4 Four holes 2,8 for tools, depth = 1,27 5 RAA 1,0 DIN 82 knurling 6 RKV 08 DIN 82 knurling NOTE Valley of start tooth to be at vertical centre line of

29、 accessory at position shown: within 3 for shell sizes 08 12; within 2 for shell sizes 14 18; within 1 for shell sizes 20 and larger. Figure 1 Cable outlet 8,06-9,34 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking per

30、mitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 6 Table 1 Fixed dimensions of shell Dimensions in millimetres Shell size A B C D E G H J N max. max. Thread 0 0,25 max. max. max. Numberof teeth 08 22,48 15,67 0.500-20UNF 6,86 15,3 14,8 10,2 31,05 12 10 25,65 18,64 0.625-24

31、UNEF 9,53 15,3 16,6 13,7 34,21 15 12 28,83 21,79 0.750-20UNEF 12,98 15,3 18,1 16,8 37,95 21 14 32,00 24,99 0.875-20UNEF 14,86 15,3 18,7 17,9 39,65 24 16 35,18 28,24 1.000-20UNEF 18,03 15,3 20,3 21,2 41,25 30 18 38,55 30,94 1.062-18UNEF 20,04 15,3 21,3 23,2 43,65 33 20 41,53 34,16 1.188-18UNEF 23,22

32、15,3 22,8 26,2 46,91 36 22 44,70 37,29 1.312-18UNEF 26,39 15,3 24,4 29,4 50,10 39 24 47,89 40,46 1.438-18UNEF 29,31 15,3 26,1 32,6 53,26 42 Table 2 Mass for classes K, F and W Mass in grams Shell size code End-fitting size code Length code wiring chamber A B C D E F G H J K L M 08 26,1 10 41,9 42,6

33、44,0 12 52,4 52,4 53,2 14 64,0 B 16 78,0 18 87,8 89,8 20 106,2 110,4 B 22 120,3 121,4 123,3 24 141,2 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-06

34、5:2009 (E) 7 4.2 Cable entry dimensions See Figure 2 and Table 3. Figure 2 Dimensions Table 3 Dimensions in millimetres End-fitting size code A B C D Bundle/cable diameter 0,1 0,3 min. min. max. A 4,7 7,7 12,2 1,12 2,0 4,0 B 6,4 9,4 14,0 1,12 3,9 5,5 C 7,9 11,0 15,5 1,12 5,4 7,5 D 9,5 12,6 17,1 1,12

35、 7,4 9,0 E 11,1 14,1 18,7 1,12 9,4 10,5 F 12,7 15,7 20,3 1,12 10,4 12,0 G 15,9 18,9 23,5 1,12 12,4 15,5 H 19,1 22,0 26,7 1,12 15,4 18,5 J 22,2 25,2 29,8 1,75 18,4 21,5 K 25,5 28,4 33,0 1,75 21,4 25,0 L 28,6 31,5 36,2 1,75 25,4 28,0 M 31,8 34,7 39,4 1,75 28,4 31,0 NOTE The cable outlet shall be selec

36、ted in accordance with the diameter of the cable to be hardened. 4.3 Associated connectors See EN 3660-002. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN

37、3660-065:2009 (E) 8 4.4 Interface dimensions Standard AS85049 interface. See Figure 3, Figure 4 and Table 4. All dimensions are in millimetres. Key 1 4,95 mm min. penetration of Z diameter measured from front of teeth. 2 N number of teeth, see Table 3. Figure 3 Standard interface Figure 4 Standard i

38、nterface dimensions Table 4 Dimensions in millimetres Shell size W X Y Z N + 0,64 0 0 0,38 + 0,38 0 0 0,25 Number of teeth 08 12,70 9,14 7,59 6,86 12 10 15,88 12,55 11,00 9,53 15 12 19,05 15,49 13,94 12,98 21 14 22,23 18,67 17,12 14,86 24 16 25,40 21,84 20,29 18,03 30 18 26,97 23,27 22,07 20,04 33 2

39、0 30,98 26,44 25,25 23,22 36 22 33,32 29,62 28,42 26,39 39 24 36,53 32,79 31,60 29,31 42 Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 9

40、 4.5 Material and finish Material/Finish Class F : Aluminium/Nickel plated Material/Finish Class K : Stainless steel/Passivated Material/Finish Class W : Aluminium/Olive drab cadmium plated 4.6 Robustness assembly torque These torque values are intended for installation use only, see Table 5. Table

41、5 Shell size Robustness assembly torque max. Nm Class K Classes F and W 08 7,6 5,1 10 10,2 5,1 12 14,2 5,1 14 15,3 5,1 16 15,3 5,1 18 15,3 10,2 20 17,8 10,2 22 17,8 10,2 24 17,8 10,2 5 Tests 5.1 Tests according to EN 2591-100 Test details to be in accordance with Table 6, EN 3660-001 and EN 2591-100

42、. Qualification to be in accordance with EN 3660-001. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 10 Table 6 EN 2591- Designation of t

43、he test Not applicable Applicable see EN 3660-001Details 101 Visual examination X 102 Examination of dimensions and mass X See 4.1 and 4.2. 205 Housing (shell) electrical continuity X Cable outlet connector connection add maximum to the values given. Class F: 2,5 m; Class W: 5 m; Class K: 10 m. 212

44、Surface transfer impedance (from 100 MHz to 1 GHz) aX Frequency Zt (m) MHz Class F Class W Class K 0,1 5 10 20 1 5 10 20 10 7 15 30 30 10 20 40 100 20 40 80 Test mounting as per 5.2. The Zt values correspond to the total surface impedance of the assembly. Test shall be achieved with a same size and

45、class couple connectors EN 2997 (all parts) than the accessory. continued Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 3660-065:2009EN 3660-065:2009 (E) 11 Table 6 (cont

46、inued) EN 2591- Designation of the test Not applicable Applicable see EN 3660-001Details 213 Shielding effectiveness from 100 MHz to 1 GHz X Frequency Minimum attenuation Classes F and W Class C MHz dB dB 100 90 80 200 88 75 300 88 73 400 87 71 800 85 66 1 000 85 65 301 Endurance at temperature X 30

47、5 Rapid change of temperature X ClassesTATBT1+ 5 0 0 5 C C min. F 200 65 30 W 175 65 30 K 260 65 30 306 Mould growth X See EN 3660-001. 307 Salt mist X Cable outlet not fitted to a connector and suspended with non-metallic cord. Duration: Class F 48 h Class W 500 h Class K 500 h 308 Sand and dust X 314 Immersion at low air pressure X 315 Fluid resistance X 316 Ozone resistance X 317 Flammability X 318 Fire-resistance X Class K only continued Copyright European Committee for Standardization Provided b

展开阅读全文