EN 14600-2005 en Doorsets and openable windows with fire resisting and or smoke control characteristics - Requirements and classification《带耐火和 或烟控特性的整樘门和可开窗 要求和分类》.pdf

上传人:proposalcash356 文档编号:714311 上传时间:2019-01-04 格式:PDF 页数:30 大小:839.91KB
下载 相关 举报
EN 14600-2005 en Doorsets and openable windows with fire resisting and or smoke control characteristics - Requirements and classification《带耐火和 或烟控特性的整樘门和可开窗 要求和分类》.pdf_第1页
第1页 / 共30页
EN 14600-2005 en Doorsets and openable windows with fire resisting and or smoke control characteristics - Requirements and classification《带耐火和 或烟控特性的整樘门和可开窗 要求和分类》.pdf_第2页
第2页 / 共30页
EN 14600-2005 en Doorsets and openable windows with fire resisting and or smoke control characteristics - Requirements and classification《带耐火和 或烟控特性的整樘门和可开窗 要求和分类》.pdf_第3页
第3页 / 共30页
EN 14600-2005 en Doorsets and openable windows with fire resisting and or smoke control characteristics - Requirements and classification《带耐火和 或烟控特性的整樘门和可开窗 要求和分类》.pdf_第4页
第4页 / 共30页
EN 14600-2005 en Doorsets and openable windows with fire resisting and or smoke control characteristics - Requirements and classification《带耐火和 或烟控特性的整樘门和可开窗 要求和分类》.pdf_第5页
第5页 / 共30页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 14600:2005Doorsets and openable windows with fire resisting and/or smoke control characteristics Requirements and classificationThe European Standard EN 14600:2005 has the status of a British Standardg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g

2、44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58ICS 91.060.50Incorporating Corrgendum 2009MarchBS EN 14600:2005This British Standard was published under the authority of the Standards Policy and Strategy Committee on 16 Januar

3、y 2006 BSI 2009ISBN 978 0 580 67193 7National forewordThis British Standard is the official English language version of EN 14600:2005.The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/1, W

4、indows, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulg

5、ate them in the UK.A list of organizations represented on this subcommittee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitl

6、ed “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance w

7、ith a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 26, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when th

8、e document was last issued.Amendments issued since publicationDate Comments31 March 2009 Correction to in Annex FfigureEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14600August 2005ICS 91.060.50English VersionDoorsets and openable windows with fire resisting and/or smokecontrol characteristics -

9、 Requirements and classificationBlocs-portes et fentres ouvrantes rsistant au feu et/oupare-fumes - Exigences et classificationTore, Tren und zu ffnende Fenster mit Feuer- und/oderRauchschutzeigenschaften - Anforderungen undKlassifizierungThis European Standard was approved by CEN on 25 May 2005.CEN

10、 members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on applic

11、ation to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the

12、same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Sl

13、ovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN na

14、tional Members.Ref. No. EN 14600:2005: EBS EN 14600:2005EN 14600:2005 (E) 2 Contents Page Foreword. 3 Introduction 4 1 Scope . 5 2 Normative references . 5 3 Terms and definitions. 7 4 Requirements 8 5 Test methods. 15 6 Summary of evidence required and resulting classifications . 17 7 Marking 18 8

15、Maintenance instructions 18 Annex A (normative) Characteristics for building hardware for use on fire resisting doorsets or fire resisting openable windows and smoke control doorsets 19 Annex B (normative) Classification requirements for elements of building hardware . 21 Annex C (normative) Inspect

16、ion and maintenance . 22 Annex D (normative) Glass products to be incorporated in fire resisting doorsets and openable windows and/or medium temperature smoke control doorsets 23 Annex E (informative) Route to classification for fire resisting doorsets and fire resisting openable windows. 24 Annex F

17、 (informative) Route to classification for smoke control doorsets . 25 Bibliography . 26 BS EN 14600:2005EN 14600:2005 (E) 3 Foreword This European Standard (EN 14600:2005) has been prepared by Technical Committee CEN/TC 033 “Doors, windows, shutters, building hardware and curtain walling”, the secr

18、etariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2006, and conflicting national standards shall be withdrawn at the latest by February 2006. Annex E and

19、F of this document provide information relating this document to other relevant European Standards, some of which are in the course of development. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European

20、Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 14600:2005EN

21、 14600:2005 (E) 4 Introduction Fire resisting doorsets and openable windows are required to provide adequate protection to openings in fire resisting walls or partitions which are formed as doorways for the passage of people, goods or vehicles. Smoke control characteristics may be added to fire resi

22、sting doorsets or may be required as a sole characteristic for smoke control doorsets to provide smoke leakage protection to doorways in walls or partitions which are not required to be fire resisting. Fire resisting doorsets and openable windows and smoke control doorsets can only provide their des

23、igned fire resistance or smoke control capability when they are in the closed position. This European Standard identifies the requirements and methods of conformity necessary to demonstrate that a measured fire resistance or smoke control capability can be assumed to cover their designed working lif

24、e. To that end, this document identifies operational requirements and test/inspection methods which are intended to demonstrate durability of self closing and operational capabilities combined with fire resistance and/or smoke control. In order to ensure continued performance of the characteristics,

25、 there is a need for routine inspection and maintenance. See normative Annex C. BS EN 14600:2005EN 14600:2005 (E) 5 1 Scope This European Standard identifies the particular requirements and classifications necessary to demonstrate the characteristics of fire resistance, smoke leakage control and sel

26、f closing durability for pedestrian doorsets, industrial type doorsets and openable windows. Requirements for performance characteristics for these products can be found in the appropriate product standards. This document does not cover any component reliability or durability testing of mechanical h

27、eat detectors (e.g. fusible link devices). The requirements relating to the use of alternative items of building hardware are provided. NOTE 1 Fire resistance of doorsets and fire resistance of openable windows and smoke control of doorsets which differ from the original test specimen(s) are covered

28、 by the fields of direct and extended application relative to the result of test(s) to EN 1634-1 for fire resistance and EN 1634-3 for smoke control. NOTE 2 Smoke venting windows designed to open in the event of fire are not covered by this standard. 2 Normative references The following referenced d

29、ocuments are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 179, Building hardware Emergency exit devices operated by a lever handle

30、 or push pad Requirements and test methods EN 572-9:2004, Glass in building Basic soda lime silicate glass products Part 9: Evaluation of conformity/Product standard EN 1096-4:2004, Glass in building Coated glass Part 4: Evaluation of conformity/Product standard EN 1125, Building hardware Panic exit

31、 devices operated by a horizontal bar Requirements and test methods EN 1154, Building hardware Controlled door closing devices Requirements and test methods EN 1155, Building hardware Electrically powered hold-open devices for swing doors Requirements and test methods EN 1158, Building hardware Door

32、 coordinator devices Requirements and test methods EN 1191, Windows and doors Resistance to repeated opening and closing Test method EN 1279-5:2001, Glass in building Insulating glass units Part 5: Evaluation of conformity EN 1303, Building hardware Cylinders for locks Requirements and test methods

33、EN 1364-1, Fire resistance tests for non-loadbearing elements Part 1: Walls EN 1527, Building hardware Hardware for sliding doors and folding doors Requirements and test methods EN 1634-1, Fire resistance tests for door and shutter assemblies Part 1: Fire doors and shutters prEN 1634-2, Fire resista

34、nce tests for door and shutter assemblies Part 2: Fire door hardware Building hardware for fire resisting doorsets and openable windows EN 1634-3, Fire resistance tests for door and shutter assemblies Part 3: Smoke control doors and shutters BS EN 14600:2005EN 14600:2005 (E) 6 EN 1748-1-2:2004, Glas

35、s in building Special basic products Borosilicate glasses - Part 1-2: Evaluation of conformity/Product standard EN 1748-2-2:2004, Glass in building Special basic products Glass ceramics - Part 2-2: Evaluation of conformity/Product standard EN 1863-2:2004, Glass in building Heat strengthened soda lim

36、e silicate glass Part 2: Evaluation of conformity/Product standard EN 1906, Building hardware Lever handles and knob furniture Requirements and test methods EN 1935, Building hardware Single-axis hinges Requirements and test methods EN 12051, Building hardware Door and window bolts Requirements and

37、test methods EN 12150-2:2004, Glass in building Thermally toughened soda lime silicate safety glass Part 2: Evaluation of conformity/Product standard EN 12209, Building hardware Locks and latches Mechanically operated locks, latches and locking plates Requirements and test methods EN 12337-2:2004, G

38、lass in building Chemically strengthened soda lime silicate glass Part 2: Evaluation of conformity/Product standard EN 12433-1:1999, Industrial, commercial and garage doors and gates Terminology Part 1: Types of doors EN 12433-2:1999, Industrial, commercial and garage doors and gates Terminology Par

39、t 2: Parts of doors EN 12453, Industrial, commercial and garage doors and gates Safety in use of power operated doors Requirements EN 12519:2004, Windows and pedestrian doors Terminology EN 12605, Industrial, commercial and garage doors and gates Mechanical aspects Test methods prEN 12650-2, Buildin

40、g hardware Powered pedestrian doors Part 2: Safety at powered pedestrian doors EN 13024-2:2004, Glass in building Thermally toughened borosilicate safety glass Part 2: Evaluation of conformity/Product standard EN 13501-2, Fire classification of construction products and building elements Part 2: Cla

41、ssification using data from fire resistance tests, excluding ventilation services prEN 13633, Building hardware Electrically controlled panic exit systems for use on escape routes Requirements and test methods prEN 13637, Building hardware Electrically controlled emergency exit systems for use on es

42、cape routes Requirements and test methods EN 14178-2:2004, Glass in building Basic alkaline earth silicate glass products Part 2: Evaluation of conformity/Product standard EN 14179-2:2001, Glass in building Heat soaked thermally toughened soda lime silicate safety glass Part 2: Evaluation of conform

43、ity/Product standard prEN 14321-2:2001, Glass in building Thermally toughened alkaline earth silicate safety glass Part 2: Evaluation of conformity/Product standard EN 14449:2002, Glass in building Laminated glass and laminated safety glass Evaluation of conformity/Product standard BS EN 14600:2005E

44、N 14600:2005 (E) 7 prEN 14637:2003, Building hardware Electrically controlled hold-open systems for fire/smoke door assemblies Requirements, test methods, application and maintenance prEN 14846, Building hardware Locks and latches Part 3: Electromechanically operated locks and striking plates Requir

45、ements and test methods CEN/TS 54-14:2004, Fire detection and fire alarm systems Part 14 Guidelines for planning, design, installation, commissioning, use and maintenance 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 12433-1:1999, EN 12433-

46、2:1999, EN 12519:2004, prEN 14637:2003 and the following apply. 3.1 closing device device to be attached to a doorset or openable window which provides a return to the closed position 3.2 designed working life period of time for which the complete assembly is designed to operate, when installed and

47、maintained in accordance with the manufacturers instructions 3.3 door co-ordinating device mechanism which ensures the correct sequence of closing of double leaf single swing doorsets 3.4 fire resisting doorset pedestrian doorset or industrial type doorset including any frame or guide, door leaf or

48、leaves, rolling or folding curtain, etc., which is provided to give a fire resisting capability when used for the closing of permanent openings in fire resisting separating elements. This includes any side panels, vision panels or transom panels together with the door building hardware and any seals

49、 (whether provided for the purpose of fire resistance or smoke control or for other purposes such as draught or acoustics) which form the assembly 3.5 fitness for purpose ability of a product, process or service to serve a defined purpose under specific conditions 3.6 friable material material that changes in physical size under mechanical impact, acceleration, deceleration, in such a way that its performance for t