1、BSI Standards PublicationBS EN 14749:2016Furniture Domestic andkitchen storage units andkitchen-worktops Safetyrequirements and test methodsBS EN 14749:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 14749:2016.It supersedes BS EN 14749:2005 which is withdr
2、awn.The UK participation in its preparation was entrusted to TechnicalCommittee FW/0/2, Domestic and Contract Furniture.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contr
3、act. Users are responsible for its correctapplication. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 83105 8ICS 97.040.10; 97.140Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under th
4、e authority of theStandards Policy and Strategy Committee on 29 February 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 14749:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14749 February 2016 ICS 97.040.10; 97.140 Supersedes EN 14749:2005English Versi
5、on Furniture - Domestic and kitchen storage units and kitchen-worktops - Safety requirements and test methodsAmeublement - Meubles de rangement domestiques et de cuisine et plans de travail de cuisine - Exigences de scurit et mthodes dessai Mbel - Wohn- und Kchenbehltnismbel und Kchenarbeitsplatten
6、- Sicherheitstechnische Anforderungen und Prfverfahren This European Standard was approved by CEN on 21 November 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without
7、any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other lang
8、uage made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmar
9、k, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE F
10、OR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14749:2016 EBS EN 14749:2016EN 1
11、4749:2016 (E) 2 Contents Page European foreword . 4 Introduction 5 1 Scope 6 2 Normative references 6 3 Terms and definitions . 6 4 Test procedure and tolerances 9 4.1 General 9 4.2 Sequence of testing . 9 4.3 Tolerances . 9 5 Safety requirements . 9 5.1 Principles of safety requirements . 9 5.1.1 G
12、eneral 9 5.1.2 Determination of centre of gravity . 9 5.1.3 Determination of total mass . 10 5.2 General safety requirements . 10 5.2.1 General . 10 5.2.2 Units moving vertically 10 5.2.3 Lids 10 5.2.4 Vertically moving roll fronts and vertically moving sliding doors 11 5.2.5 Extension elements . 11
13、 5.3 Structural safety requirements . 11 5.3.1 General . 11 5.3.2 Shelves . 11 5.3.3 Shelf supports 11 5.3.4 Storage area/-volume for heavy appliances 12 5.3.5 Pivoted doors . 12 5.3.6 Sliding doors and horizontal roll fronts 12 5.3.7 Extension elements . 12 5.3.8 Bottom hinged flaps 13 5.3.9 Top hi
14、nged flaps . 13 5.3.10 Kitchen-worktops and other top surfaces 13 5.3.11 Wall hanging units and top hanging units . 14 5.4 Stability 15 5.4.1 General . 15 5.4.2 Kitchen floor units with kitchen-worktops 16 5.4.3 Stability of TV-furniture 16 5.5 Floor standing units intended to be attached to the bui
15、lding 17 5.6 Vertical glass components 17 6 Product information . 17 7 Test report 18 Annex A (normative) Additional test methods . 19 A.1 Vertical downwards static load of top hinged flaps . 19 A.2 Stability of TV-furniture 19 A.2.1 One door, extension element or flap opened storage areas unloaded
16、19 BS EN 14749:2016EN 14749:2016 (E) 3 A.2.2 Doors, extension elements and flaps closed storage areas unloaded 20 A.3 Sidewards detachment test . 20 Annex B (informative) Guide to testing of units and components . 22 Annex C (informative) Example of loading of wall hanging units and top hanging unit
17、s (see 5.3.11.3 overload). 27 Annex D (informative) Method for calculation of vertical and horizontal acting forces . 28 Bibliography . 32 BS EN 14749:2016EN 14749:2016 (E) 4 European foreword This document (EN 14749:2016) has been prepared by Technical Committee CEN/TC 207 “Furniture”, the secretar
18、iat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2016, and conflicting national standards shall be withdrawn at the latest by February 2017. Attention is drawn t
19、o the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 14749:2005. Compared to EN 14749:2005 the following modifications have been ma
20、de: a) structure revised; b) the most test methods removed and replaced by a reference to EN 16122:2012, Domestic and non-domestic storage furniture Test methods for the determination of strength, durability and stability; c) Clause 3 “Terms and definitions” extended; d) tests for stability of TV-fu
21、rniture added; e) Annex B (informative) “Guide to testing of units and components” amended; f) Annex D (informative) “Relation between safety requirements, total mass and position of centre of gravity of loaded units or loaded components” deleted; g) new Annex D (informative) containing a method for
22、 calculation of vertical and horizontal acting forces added. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia
23、, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 14749:2016EN 14749:2
24、016 (E) 5 Introduction With this revision the included test methods have been as far as possible taken out of the standard and referenced to: EN 16122:2012, Domestic and non-domestic storage furniture Test methods for the determination of strength, durability and stability. This standard was prepare
25、d in order to provide assurance that domestic storage furniture and kitchen-worktops comply with the given requirements and are safe. The intention of this European Standard is the prevention of serious injury through normal use, as well as foreseeable misuse. It cannot ensure that structural failur
26、e will not eventually occur as a result of habitual misuse. Co-ordinating sizes for kitchen furniture (including kitchen-worktops) kitchen appliances, sinks and decorative panels are covered by EN 1116, Kitchen furniture Co-ordinating sizes for kitchen furniture and kitchen appliances. BS EN 14749:2
27、016EN 14749:2016 (E) 6 1 Scope This European Standard specifies safety requirements and test methods for all types of kitchen and bathroom storage units and domestic storage furniture and their components. It does not apply to non-domestic storage, office storage, industrial storage, catering equipm
28、ent, retail storage and industrial storage lockers. It does not apply to units covered by EN 71-1, Safety of toys Part 1: Mechanical and physical properties and EN 60065, Audio, video and similar electronic apparatus Safety requirements (IEC 60065). It does not include requirements for the resistanc
29、e to ageing, degradation, flammability and electrical safety. Safety that is dependent upon the structure of the building is not included, e.g. the strength of wall hanging units includes only the cabinet and its components including wall attachment devices. The wall and the wall attachments are not
30、 included. Annex A (normative) contains additional test methods. Annex B (informative) contains a guide to testing of units and components according to this document. Annex C (informative) contains an example of loading of wall hanging units. Annex D (informative) contains a method for calculation o
31、f vertical and horizontal acting forces. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the
32、 referenced document (including any amendments) applies. EN 71-1:2014, Safety of toys - Part 1: Mechanical and physical properties EN 12150-1:2015, Glass in building Thermally toughened soda lime silicate safety glass Part 1: Definition and description EN 12600, Glass in building - Pendulum test - I
33、mpact test method and classification for flat glass EN 14072:2003, Glass in furniture - Test methods EN 16122:2012, Domestic and non-domestic storage furniture - Test methods for the determination of strength, durability and stability 3 Terms and definitions For the purposes of this document, the fo
34、llowing terms and definitions apply. 3.1 unit piece of storage furniture 3.2 free standing unit unit not intended to be attached to a load bearing structure BS EN 14749:2016EN 14749:2016 (E) 7 3.3 floor standing unit intended to be attached to the building unit intended to be supported by the floor
35、and also attached to a structure 3.4 wall hanging unit unit intended to be entirely supported by a vertical structure Note 1 to entry: A vertical structure can be a wall, panel or screen. 3.5 wall attachment device device including the component that is attached to the cabinet and the component that
36、 is attached to the wall Note 1 to entry: A component that is attached to the cabinet is e.g. a suspension bracket. Note 2 to entry: A component that is attached to the wall is e.g. a hook, a rail. 3.6 kitchen-worktop work surface primarily intended to be used for preparing food 3.7 TV-furniture uni
37、t designed to support a TV-set 3.8 component part of a unit including hardware 3.9 extension element component that can be pulled out and pushed in Note 1 to entry: An extension element can be a basket, a drawer or a suspended pocket file. 3.10 storage area storage volume space in furniture for stor
38、age Note 1 to entry: A storage area/-volume can be in extension elements and on shelves, bottoms and tops. 3.11 accessible part part to which access can easily be gained by the user when in its intended configuration of use and for which the probability of unintentional user contact is high Note 1 t
39、o entry: This includes, but is not limited to: the exposed edges and corners of storage units to which the user has access when the doors, drawers and extension elements are closed, the corners and edges of handles. BS EN 14749:2016EN 14749:2016 (E) 8 3.12 shear and squeeze point distance between tw
40、o accessible parts moving relative to each other which can be 25 mm or 8 mm in any position during movement 3.13 clear height unobstructed height above the top of the bottom surface Note 1 to entry: See Figure 1. Key 1 structure of the unit 2 clear height 3 extension element Figure 1 Clear height SO
41、URCE: EN 16122:2012, 3.2 modified - or the structure of the unit has been deleted; another figure has been included 3.14 levelling device adjustable device intended to keep the item of furniture perpendicular to the floor Note 1 to entry: A levelling device can be an adjustable foot or similar. 3.15
42、 potential energy multiplication of the total mass (kg) of the unit (or the component), gravity (m/s2) and the height (m) above the floor to the centre of gravity Note 1 to entry: For the purpose of this European Standard gravity can be considered to be 10 m/s2. BS EN 14749:2016EN 14749:2016 (E) 9 3
43、.16 overturn event at which a furniture unit pivots to a point beyond which the unit continues to fall 4 Test procedure and tolerances 4.1 General For all tests referred to in this standard, EN 16122:2012, Clause 4 “General test conditions” and EN 16122:2012, Clause 5 “Test equipment and apparatus”
44、apply. 4.2 Sequence of testing The tests shall be carried out in the same sequence as the clauses are numbered in this European Standard. 4.3 Tolerances Unless otherwise stated, the following tolerances are applicable: Forces: 5 % of the nominal force; The forces may be replaced by masses. The relat
45、ionship 10 N = 1 kg should be used. Velocities: 5 % of the nominal velocity; Masses: 1 % of the nominal mass; Dimensions: 1 mm of the nominal dimension; Angles: 2 of the nominal angle. NOTE For the purposes of uncertainty measurement, test results are not considered to be adversely affected when the
46、 above tolerances are met. 5 Safety requirements 5.1 Principles of safety requirements 5.1.1 General The safety requirements are based upon the knowledge that kitchen units, bathroom units and domestic storage furniture and their components are likely to cause serious injury only when they are heavy
47、 and fall through a significant distance. This is possible if floor standing units overturn, wall or screen hanging units become detached, or heavy components become detached from units. 5.1.2 Determination of centre of gravity The centre of gravity above the floor (for floor standing units) shall b
48、e measured when installed according to the manufacturers instructions. Levelling devices shall be set at their middle position. Height adjustable components shall be placed in their highest position. The centre of gravity of a component or unit shall be taken as the geometric centre of that unit, ex
49、cept in the case of extension elements, where the geometric centre of the usable volume shall be used. All wall hanging units or top hanging units or components thereof are considered to have their centre of gravity more than 900 mm above the floor. BS EN 14749:2016EN 14749:2016 (E) 10 5.1.3 Determination of total mass The total mass is the mass of the component or unit plus the mass determined according to Table 1, unless the unit or component is conspicuously and durably marked by the manufacturer with a maximu