1、BS EN 15092:2008ICS 91.140.60NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDBuilding valves Inline hot watersupply temperingvalves Tests andrequirementsThis British Standardwas published underthe authority of theStandards Policy andStrategy Committee on 30Septe
2、mber 2008 BSI 2008ISBN 978 0 580 54889 5Amendments/corrigenda issued since publicationDate CommentsBS EN 15092:2008National forewordThis British Standard is the UK implementation of EN 15092:2008.The UK committee would like to draw attention to the followingconcerns:1.Subclause 7.6.2 requires that f
3、low changes be accomplished within10,5 seconds. This necessitates that valve 5 shown in Annex B is morethan a simple on/off control.2.The acoustic test in Subclause 8.2 references EN ISO 3822. Thisrequires the test to be conducted with cold water at both inlets;therefore arrangements need to be made
4、 to enable adjustment of thetemperature setting of the valve over the whole range in order to satisfythe requirements of EN ISO 3822 and Subclause 8.2.3.Annexes A and B are informative, yet there are several references tothese Annexes within Clause 7. This could result in irreproducibility, andincon
5、sistencies in certifications.The UK participation in its preparation was entrusted to TechnicalCommittee B/504/7, Valves and fittings for buildings.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the ne
6、cessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 15092:2008EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 15092June 2008ICS 91.140.60English VersionBuilding valves - Inline hot
7、water supply tempering valves - Testsand requirementsRobinetterie des btiments - Vannes mlangeuses en lignedalimentation en eau chaude - Essais et exigencesGebudearmaturen - Thermostatische Mischer frWarmwasserbereiter - Prfungen und AnforderungenThis European Standard was approved by CEN on 29 May
8、2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained o
9、n application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Cen
10、tre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
11、 Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any mea
12、ns reservedworldwide for CEN national Members.Ref. No. EN 15092:2008: EBS EN 15092:2008EN 15092:2008 (E) 2 Contents Page Foreword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Materials and surface finishes .7 4.1 General7 4.2 Nature of materials 7 5 Design and dim
13、ensional requirements .8 5.1 Backflow prevention8 5.2 Dimensional characteristics .8 5.3 Set temperature adjustment .10 5.4 Temperature override function.10 6 Mechanical tests and requirements.10 6.1 Body strength test .10 6.2 Bending moment test for tempering valves10 6.3 Torque tests for temperatu
14、re stops.11 7 Performance tests and requirements 12 7.1 General12 7.2 Standard test conditions.12 7.3 Verification of valve temperature settings 13 7.4 Determination of minimum flow rate .14 7.5 Test for temperature stability starting from ambient.16 7.6 Test for temperature stability with changing
15、flow rates17 7.7 Test for thermal shutoff with cold water supply failure.18 7.8 Test for temperature stability with changing inlet pressure .18 7.9 Test for temperature stability with changing inlet temperature .19 7.10 Endurance test on the thermostat .20 8 Acoustic tests and requirements.21 8.1 Ge
16、neral21 8.2 Test method21 8.3 Expression of results 21 8.4 Requirements.21 9 Classification21 10 Designation 21 11 Marking .22 11.1 Temperature marking 22 11.2 Flow marking22 11.3 Identification marking .22 12 Instructions 22 Annex A (informative) Apparatus for endurance test on thermostat.24 Annex
17、B (informative) Apparatus for performance test 26 Annex C (normative) Measurement of parameters28 Annex D (informative) Temperature transient requirements 29 Bibliography 30 BS EN 15092:2008EN 15092:2008 (E) 3 Foreword This document (EN 15092:2008) has been prepared by Technical Committee CEN/TC 164
18、 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2008, and conflicting national standards shall be withdrawn at the latest by De
19、cember 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards
20、 organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Repub-lic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portu
21、gal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15092:2008EN 15092:2008 (E) 4 Introduction In respect of potential adverse effect on the quality of water intended for human consumption, caused by the product covered by this European Standard: a) this Europe
22、an Standard provides no information as to whether the product may be used without restric-tion in any of the Member States of the EU or EFTA; b) it should be noted that, while awaiting the adoption of verifiable European criteria, existing national regu-lations concerning the use and/or the characte
23、ristics of this product remain in force. BS EN 15092:2008EN 15092:2008 (E) 5 1 Scope This European Standard specifies dimensions, materials and performance requirements (including methods of test) for in line hot water supply tempering valves for sanitary hot water systems, of nominal sizes from DN
24、15 to DN 50. Tempering valves reduce the temperature of sanitary hot water for distribution throughout the hot water system. The conditions of use are specified in Table 1. The valves are intended to be used with storage water heaters to provide tempered hot water to the terminal fitting. They are n
25、ot intended to control the temperature at the point of use. Tempering valves control the distribution temperature from a water heater to a preset value or an adjustable range, both between 45 C and 65 C. Table 1 Conditions of use Limits of use Recommended limits for operation Dynamic pressure 0,02 M
26、Pa (0,2 bar) min. 0,1 MPa P 0,5 MPa (1 bar P 5,0 bar) Static pressure 1 MPa (10 bar) max. Hot water inlet temperature T 90 C 60 C T 80 C Cold water inlet temperatures T 25 C T 25 C Distribution (outlet) temperature 45 C T 65 C 2 Normative references The following referenced documents are indispensab
27、le for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1092-3, Flanges and their joints Circular flanges for pipes, valves, fittings and accessories, P
28、N desig-nated Part 3: Copper alloy flanges EN 1254-1, Copper and copper alloys Plumbing fittings Part 1: Fittings with ends for capillary soldering or capillary brazing to copper tubes EN 1254-2, Copper and copper alloys Plumbing fittings Part 2: Fittings with compression ends for use with copper tu
29、bes EN 1254-3, Copper and copper alloys Plumbing fittings Part 3: Fittings with compression ends for use with plastics pipes EN 1254-4, Copper and copper alloys Plumbing fittings Part 4: Fittings combining other end connections with capillary or compression ends EN 1254-5, Copper and copper alloys P
30、lumbing fittings Part 5: Fittings with short ends for capillary braz-ing to copper tubes EN 1982, Copper and copper alloys Ingots and castings EN 12164, Copper and copper alloys Rod for free machining purposes EN 12165, Copper and copper alloys Wrought and unwrought forging stock EN 13959, Anti-poll
31、ution check valves DN 6 to DN 250 inclusive family E, Types A, B, C and D BS EN 15092:2008EN 15092:2008 (E) 6 EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the thread Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) EN ISO 3822-1, Acoustics Laboratory tests on
32、 noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement (ISO 3822-1:1999) EN ISO 3822-3, Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for
33、in-line valves and appliances (ISO 3822-3:1997) EN ISO 6509, Corrosion of metals and alloys Determination of dezincification resistance of brass (ISO 6509:1981) ISO 7-1:1994, Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, toler-ances and designation 3 Terms and
34、definitions For the purposes of this document, the following terms and definitions apply. 3.1 tempering valve temperature activated valve which mixes hot and cold water to achieve a pre-determined outlet temperature and which is fitted between the water heater and the point of use to control the dis
35、tribution temperature to be-tween 45 C and 65 C 3.2 maximum distribution temperature maximum hot water outlet temperature at which the tempering valve is designed to be used and which is 65 C; national regulations may set a lower value distribution temperature 3.3 minimum distribution temperature 45
36、 C which is the minimum hot water outlet temperature at which the tempering valve is designed to be used 3.4 pre-set temperature temperature as set by the manufacturer of the valve 3.5 set temperature distribution temperature between 45 C to 65 C 3.6 adjustable valve valve with a control mechanism w
37、hich enables the distribution temperature to be adjusted from one set point to another set point within a pre-determined minimum and maximum value 3.7 temperature override function facility for temporary use, that allows a temperature in excess of the normal distribution temperature of 65 C to enter
38、 the hot water distribution system for thermal disinfection to control the growth of bacteria 3.8 Type 1 tempering valve non-adjustable tempering valve with pre-set temperature BS EN 15092:2008EN 15092:2008 (E) 7 3.9 Type 2 tempering valve tempering valve adjustable with or without tool and with pre
39、-set temperature 3.10 nominal diameter (DN) nominal diameter referring to the final outlet connection diameter to pipe, of the valve assembly 4 Materials and surface finishes 4.1 General The selection of materials is the responsibility of the manufacturer, provided they satisfy the following require
40、ments: a) materials and coatings shall not contaminate the potable water, when in normal or accidental contact; b) in a technical document, the manufacturer shall state the nature of the materials and coatings used; c) material with inadequate corrosion resistance shall have additional protection; d
41、) the materials used shall not deteriorate at a temperature of 95 C for 1 h and be suitable under the temperatures specified in the tests in this European Standard. 4.2 Nature of materials Examples of bronze and brass which may be used, without coating, for manufacturing purposes are given in Table
42、2. BS EN 15092:2008EN 15092:2008 (E) 8 Table 2 Examples of copper alloys Material designation Symbol Reference number European Standard CuSn10-C CC480K EN 1982 CuSn5Pb5Zn5-C CC491K EN 1982 CuSn3Zn8Pb5-C CC490K EN 1982 CuZn39Pb3 CW614N EN 12164/EN 12165 CuZn40Pb2 CW617N EN 12164/EN 12165 CuZn36Pb2As
43、CW602N EN 12164/EN 12165 Copper-zinc alloys containing more than 10 % zinc are subject to dezincification when submitted to water capable of dezincification. In the countries where the use of products made of dezincification resistant materials is required, the products have to guarantee a dezincifi
44、cation depth of less than 200 m in any direction; they have to be tested in accordance with EN ISO 6509 and have to be marked in compliance with the indications specified in Clause 11, Marking. 5 Design and dimensional requirements 5.1 Backflow prevention Integral backflow prevention devices shall c
45、omply with the appropriate standard in their own right. When fitted check valves, they shall comply with the requirements of EN 13959. 5.2 Dimensional characteristics 5.2.1 General Tempering valves shall be classified by the nominal size (DN) of outlet end connection. 5.2.2 End connections Examples
46、of end connections are given in Table 3. All end connections shall comply with EN 1254. Connec-tions requiring the use of heat to make or break the joint (e.g. capillary) are not permitted directly on the valve body. 5.2.3 Other connections (e.g. unions) Connections, other than those specified in 5.
47、2.1, shall comply with the functional aspects of the equivalent part of EN 1254. BS EN 15092:2008EN 15092:2008 (E) 9 Table 3 Examples of end connections and nominal sizes (DN 15 to DN 50) Type a DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 Internal thread to ISO 7-1:1994 d Rp Rp Rp 1 Rp 1 Rp 1 Rp 2 External
48、thread to ISO 7-1:1994 d R R R 1 R 1 R 1 R 2 External thread to EN ISO 228-1 d G B G 1 B G 1 B G 1 B G 1 BG 1 BG 2 B External thread with shoulder to EN ISO 228-1 d G B G B G 1 B G 1 B G 1 BG 1 BG 2 B G 2 BCapillary socket to EN 1254-1 A 15/18 22 28 35 42 54 Male capillary end to EN 1254-1 A 15/18 2
49、2 28 35 42 54 Compression end for copper pipe to EN 1254-2 d 15/18 22 28 35 42 54 EN 1092-3 D d K 95 75 14 105 75 14 115 85 14 140 100 18 150 110 18 160 120 18 BS EN 15092:2008EN 15092:2008 (E) 10 5.3 Set temperature adjustment If provided for, the limitation of temperature adjustment shall comply with the following. Pre-set adjustable temperature (Type 2: Valve) The pre-set temperature mechanism shall: a) be capable of adjustment to the require